Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intake temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe SCR intake temperature sensor is located in the aftertreatment system. It is located between the diesel particulate filter and the SCR catalyst in the exhaust system.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the SCR intake temperature sensor signal voltage was greater than 4.4-VDC for more than 2 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Engine torque will be severely reduced.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after four consecutive trips where the diagnostic runs and passes.

The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe SCR intake temperature sensor shares return wires in the engine harness with other sensors. An open return can cause multiple fault codes to be active.

Possible causes of this fault code include:

Open return circuit in the harness, connectors, or sensorOpen signal circuit or shorted to a voltage sourceMalfunctioning aftertreatment SCR catalyst temperature sensor interface module.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment SCR temperature sensor module failure2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3134 PID: SPN: 3610 FMI: 4 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3133 PID: SPN: 3610 FMI: 3 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe selective catalytic reduction (SCR) intake temperature sensor is used by the engine control module (ECM) to monitor the engine exhaust temperature entering the SCR catalyst. The ECM monitors the voltage on the signal pin and converts this to a temperature value.

Component LocationThe SCR intake temperature sensor is located in the aftertreatment system. It is located between the diesel particulate filter and the SCR catalyst in the exhaust system.

Conditions for Running the DiagnosticsThis diagnostic runs when the exhaust gas temperature sensors are compared to other engine temperatures during engine operation. The engine coolant temperature must be above 60°C [140°F] before the diagnostic will run.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment SCR intermediate temperature sensor signal was irrational for more than 5 minutes.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

A default value for the SCR catalyst intake temperature is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Stuck in-range SCR intake temperature sensorHigh resistance in the SCR intake temperature sensor signal or return linesMalfunctioning aftertreatment SCR catalyst temperature sensor interface module.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment SCR temperature sensor module failure2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3134 PID: SPN: 3610 FMI: 4 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment SCR temperature sensor module reported the aftertreatment SCR outlet temperature signal was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR outlet temperature sensor

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment selective catalyst reduction temperature sensor module failure2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3147 PID: SPN: 4363 FMI: 4 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment SCR temperature sensor module reported the aftertreatment SCR outlet temperature signal was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR outlet temperature sensor

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment selective catalytic reduction temperature sensor module failure2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3148 PID: SPN: 4363 FMI: 2 Aftertreatment 1 SCR Outlet Temperature Sensor- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the exhaust gas temperature sensors are compared to other engine temperatures during engine operation. The engine coolant temperature must be above 60°C [140°F] before the diagnostic will run.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment SCR outlet temperature sensor signal was irrational for more than 5 minutes.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

A default value for the SCR catalyst outlet temperature is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR outlet temperature sensor

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment selective catalytic reduction temperature sensor module2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3147 PID: SPN: 4363 FMI: 4 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3151 PID: SPN: 4794 FMI: 31 Aftertreatment 1 SCR Catalyst System Missing- Condition Exists

Circuit DescriptionThe engine control module (ECM) monitors the NOx concentration in the engine’s exhaust gases using an aftertreatment intake NOx sensor and an aftertreatment outlet NOx sensor. By comparing these two values, the ECM is able to determine the conversion efficiency of the SCR catalyst and dosing system.

Component LocationThe SCR catalyst is located in the vehicle’s exhaust system, after the diesel particulate filter and decomposition tube.

Conditions for Running the DiagnosticsThis diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the NOx conversion efficiency of the SCR catalyst was critically low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Engine torque will be severely reduced.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeIt is necessary to use the “Reset All Faults” command in INSITE™ electronic service tool to clear this fault and extinguish the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL).

Shop TalkTroubleshoot all other active NOx sensor and SCR dosing system related fault codes before this fault.

Possible causes of this fault include:

Tampering with SCR catalyst system, removal of SCR catalyst from vehicle, or malfunctioning SCR catalystMalfunctioning diesel exhaust fluid dosing systemExhaust system leaksDegraded, diluted, or incorrect diesel exhaust fluidDiesel exhaust fluid deposits in the decomposition tube.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

For unit that has come back into with repeat failures consider the possibility that customer is not using Ultra-low sulfur Diesel fuel

Possible Cause:1) N/A

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3148 PID: SPN: 4363 FMI: 2 Aftertreatment 1 SCR Outlet Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3147 PID: SPN: 4363 FMI: 4 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3165 PID: SPN: 4363 FMI: 0 Aftertreatment 1 SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Most Severe Level

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the temperature at the SCR catalyst outlet temperature sensor was greater than 800°C [1472°F] for more than 20 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.The engine will be shut down if the Engine Protection Shutdown feature is enabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault will go inactive immediately after the SCR outlet temperature drops below the warning limit, and will likely be inactive at the time of diagnosis. For these reasons this troubleshooting tree must be used for both active and inactive fault codes.

Possible causes of this fault code include:

Malfunctioning SCR catalystDegraded, diluted, or incorrect diesel exhuast fluidMalfunctioning in-range SCR outlet temperature sensor.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3151 PID: SPN: 4794 FMI: 31 Aftertreatment 1 SCR Catalyst System Missing- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3148 PID: SPN: 4363 FMI: 2 Aftertreatment 1 SCR Outlet Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3147 PID: SPN: 4363 FMI: 4 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3167 PID: SID 382 SPN: 3556 FMI: 18 Aftertreatment Doser- Data Valid But Below Normal Operaing Range- Moderately Severe Level

Circuit DescriptionThe aftertreatment fuel injector is electronically controlled by the engine electronic control module (ECM) through a pulse width modulated (PWM) signal. The amount of fuel injected is determined by how long the PWM signal to the injector is on.

Component LocationThe aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the DiagnosticsThis diagnostic runs during active regeneration of the aftertreatment diesel particulate filter.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment fuel injector could not inject enough fuel for active regeneration of the aftertreatment diesel particulate filter.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and perform the INSITE™ electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

A dirty or damaged aftertreatment fuel injector.

Possible Cause:1) Aftertreatment Injector failure2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3165 PID: SPN: 4363 FMI: 0 Aftertreatment 1 SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3151 PID: SPN: 4794 FMI: 31 Aftertreatment 1 SCR Catalyst System Missing- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3148 PID: SPN: 4363 FMI: 2 Aftertreatment 1 SCR Outlet Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3147 PID: SPN: 4363 FMI: 4 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3168 PID: SPN: 3936 FMI: 16 Aftertreatment Diesel Particulate Filter System- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe ECM calculates an aftertreatment diesel particulate filter flow resistance, using the aftertreatment diesel particulate filter differential pressure and calculated exhaust flow rate.

Component LocationThe aftertreatment diesel particulate filter is located in the exhaust system and is installed by the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic only runs after successful completion of an active regeneration of the aftertreatment diesel particulate filter.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) calculated the aftertreatment diesel particulate filter flow resistance was too low after successful regeneration of the aftertreatment diesel particulate filter.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeIt is necessary to use the “Reset All Faults” command in INSITE™ electronic service tool to clear this fault and extinguish the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL).

Shop TalkPossible causes of this fault code include:

A damaged aftertreatment diesel particulate filter differential pressure sensorMissing or malfunctioning aftertreatment diesel particulate filter differential pressure sensor tubesMalfunction aftertreatment diesel particulate filter.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Aftertreatment DPF differential pressure sensor failure2) Aftertreatment DPF differential pressure sensor tubes failure3) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3167 PID: SID 382 SPN: 3556 FMI: 18 Aftertreatment Doser- Data Valid But Below Normal Operaing Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3165 PID: SPN: 4363 FMI: 0 Aftertreatment 1 SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3151 PID: SPN: 4794 FMI: 31 Aftertreatment 1 SCR Catalyst System Missing- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3148 PID: SPN: 4363 FMI: 2 Aftertreatment 1 SCR Outlet Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3147 PID: SPN: 4363 FMI: 4 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 322 PID: SID 1 SPN: 651 FMI: 5 Injector Solenoid Driver Cylinder 1 Circuit- Current Below Normal or Open Circuit

Circuit DescriptionThe injector solenoid valves control fueling quantity and injection timing. The engine control module (ECM) energizes the solenoid by closing a high-side and a low-side switch. Each injector circuit has a dedicated low-side switch that completes the circuit path to ground inside the ECM.

Component LocationThe engine harness connects the ECM to the pass-through connector(s) that are located in the rocker housing. Internal injector harnesses are located under the valve cover and connect the injectors to the engine harness at the pass-through connector(s).

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a circuit error on an injector(s) circuit. The ECM will disable the injection event for the affected injector(s) circuit if there is excessive current.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The injector will be disabled for the malfunctioning cylinder.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf more than one injector fault code is occurring, and the faults occur for injector circuits in the same bank, a short circuit exists.

If a fault condition is intermittent, and especially if more than one injector fault code is occurring, look for a wire harness that can short to components inside the rocker housing or a short circuit to ground in the injector solenoid. When looking for short circuits in the injector harnesses, pay particular attention to the wire insulation, making sure there are no shorts to a rocker lever. An intermittent short can result if the wiring harness insulation rubs through near a rocker lever. An intermittent short can cause a single injector fault code.

If the fault(s) occur intermittently, the engine can exhibit a misfire even if the injector circuit fault code does not always register. If a single cylinder exhibits misfires, look for an open circuit problem. If several cylinders on the same bank exhibit misfires, look for a short circuit anywhere in the bank of cylinders.

Possible causes of a single injector fault include:

• Open circuit in the engine harness(es) or injector solenoid

• High resistance in a single injector or injector solenoid

• Extremely low resistance in an injector solenoid (injector shorted internally but not to ground)

• Malfunctioning or damaged ECM.

Possible causes of multiple injector fault codes in the same bank of injectors include:

Short circuit in the engine harness(es) – either shorts to ground or to other wires in the engine harnessShort circuit in any of the three injectors in the bank – shorts to groundMalfunctioning or damaged ECM.Same Bank Fault Codes:

Bank 1 – Front Bank: Fault Codes 322, 324, 331Bank 2 – Rear Bank: Fault Codes 323, 325, 332.

Possible Cause:1) Engine harness2) Injector harness3) Injector 1,2,3 failure4) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 295 PID: PID 108 SPN: 108 FMI: 2 Barometric Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 288 PID: PID 372 SPN: 974 FMI: 19 SAE J1939 Multiplexing Remote Accelerator Pedal or Lever Position Sensor System- Received Network Data In Error
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 286 PID: SID 231 SPN: 639 FMI: 13 SAE J1939 Multiplexing Configuration Error- Out of Calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 285 PID: SID 231 SPN: 639 FMI: 9 SAE J1939 Multiplexing PGN Timeout Error- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 272 PID: SID 126 SPN: 1347 FMI: 3 Engine Fuel Pump PRessurizing Assembly 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →