Ir directamente al contenido Ir directamente al menú lateral

Cumminz

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2771 PID: SPN: 3226 FMI: 9 Aftertreatment 1 Outlet Nox Sensor- Abnormal Update Rate

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) lost communication with the aftertreatment outlet Nox sensor via the J1939 data link.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Engine torque will be severely reduced.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

The Aftertreatment Outlet NOx Sensor is not receiving power from the battery supply circuit in the OEM harness. This can be caused by an open circuit in the power supply wire, blown NOx sensor fuse, or low voltage supplied by the battery.Open return circuit on the aftertreatment outlet NOx sensor battery return.Open or short circuit on the J1939 data link circuit between the engine ECM and aftertreatment outlet NOx sensor.Intermittent communications between the aftertreatment outlet NOx sensor and the primary engine ECM on the J1939 data link.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1)Open or High resistance circuit in the Aftertreatment outlet NOx sensor battery voltage supply circuit2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2764 PID: PID 131 SPN: 1209 FMI: 16 Exhaust Gas Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2754 PID: PID 81 SPN: 81 FMI: 16 Engine Diesel Particulate Filter Intake Pressure- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2739 PID: SID 237 SPN: 626 FMI: 4 Start Enable Device 1 Circuit (Ether Injection)- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2738 PID: SID 237 SPN: 626 FMI: 3 Start Enable Device 1 Circuit (Ether Injection)- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2718 PID: SPN: 520325 FMI: 31 Brake and Throttle Conflict- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2692 PID: SPN: 3936 FMI: 2 Aftertreatment 1 Diesel Particulate Filter System- Data Erratic, Intermittent, or Incorrect

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2777 PID: SID 390 SPN: 3703 FMI: 31 Particulate Trap Active Regeneration inhibited Due to Inhibit Switch- Condition Exists

Circuit DescriptionThe OEM truck manufacturer can install a permit switch in the dash or send an inhibit message via the J1939 data link to the engine ECM. The function of the inhibit message is to prevent the aftertreatment system from performing mobile regenerations.

Component LocationThe aftertreatment diesel particulate filter is located in the exhaust system and is installed by the original equipment manufacturer (OEM). The permit switch can be an actual switch in the vehicle dash or it can be a J1939 message sent via the J1939 data link. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter regeneration permit switch was disabling regeneration while the ECM was requesting active regeneration of the aftertreatment diesel particulate filter.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf this fault code is active and there has been damage to the aftertreatment system, the permit switch can possibly have prevented the aftertreatment system from performing a mobile (active) regeneration.

Consult with the OEM if the aftertreatment system has malfunctioned due to the permit switch.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2771 PID: SPN: 3226 FMI: 9 Aftertreatment 1 Outlet Nox Sensor- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2764 PID: PID 131 SPN: 1209 FMI: 16 Exhaust Gas Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2754 PID: PID 81 SPN: 81 FMI: 16 Engine Diesel Particulate Filter Intake Pressure- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2739 PID: SID 237 SPN: 626 FMI: 4 Start Enable Device 1 Circuit (Ether Injection)- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2738 PID: SID 237 SPN: 626 FMI: 3 Start Enable Device 1 Circuit (Ether Injection)- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2718 PID: SPN: 520325 FMI: 31 Brake and Throttle Conflict- Condition Exists

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2789 PID: PID 110 SPN: 110 FMI: 18 Engine Coolant Temperature- Data Valid But Below Normal Operational Range- Moderately Severe Level

Circuit DescriptionThe coolant temperature sensor is a variable resistor sensor and is used to measure the temperature of the coolant of the engine. The engine control module (ECM) supplies 5 volts to the coolant temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the coolant temperature.

Component LocationThe engine coolant temperature sensor is located on the thermostat housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesEngine coolant temperature was less than 60°C [140°F] for over 1 hour during a period of extended idle.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf this fault indicates that coolant temperature is below a calibratible limit set in the ECM.

Refer to Engine Coolant Temperature Below Normal troubleshooting symptom tree tree in the base engine service manual.

Possible Cause:1) Coolant Temperature sensor failure2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2777 PID: SID 390 SPN: 3703 FMI: 31 Particulate Trap Active Regeneration inhibited Due to Inhibit Switch- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2771 PID: SPN: 3226 FMI: 9 Aftertreatment 1 Outlet Nox Sensor- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2764 PID: PID 131 SPN: 1209 FMI: 16 Exhaust Gas Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2754 PID: PID 81 SPN: 81 FMI: 16 Engine Diesel Particulate Filter Intake Pressure- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2739 PID: SID 237 SPN: 626 FMI: 4 Start Enable Device 1 Circuit (Ether Injection)- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2738 PID: SID 237 SPN: 626 FMI: 3 Start Enable Device 1 Circuit (Ether Injection)- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 285 PID: SID 231 SPN: 639 FMI: 9 SAE J1939 Multiplexing PGN Timeout Error- Abnormal Update Rate

Circuit DescriptionNormally, switches, accelerators, and other components are connected to the engine control module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an original equipment manufacturer (OEM) vehicle electronic control unit (VECU) or transmission electronic control unit (ECU) in the cab. Then component values and states from components such as sensors, accelerators, and switches can be transmitted from the OEM VECU to the Cummins® ECM over the SAE J1939 data link.

Messages sent from OEM VECUs or transmission ECUs are received by the Cummins® ECM and used for controlling the engine. The Cummins® ECM and OEM VECU(s) must be configured properly, so that proper operation of the multiplexed components will occur.

Component LocationThe SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe ECM did not receive a message from the multiplexed device.

The Engine Control Module (ECM) detected an open or short circuit condition in the J1939 data link harness.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The multiplexed device will not operate.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkWhen this fault code is active, some multiplexed devices can possibly not function as desired.

This fault can occur for the following reasons:

When the ECM is set up properly (components enabled and OEM VECU source addressed correctly) to receive information from an OEM VECU, but the OEM VECU is actually transmitting a message that says that component is not available for multiplexing. This can be caused when a multiplexed component is enabled in the ECM, but the OEM VECU source address of the VECU transmitting the component message is incorrect in the Cummins® ECM, or the OEM VECU is not set up to transmit the multiplexed component message.This fault can also be caused by a damaged J1939 data link connection between the OEM VECU and Cummins® ECM, a damaged connection between the component and the OEM VECU, damaged OEM VECU or damaged Cummins® ECM. It can become necessary to contact the OEM for proper multiplexing configuration.It is possible to use INSITE™ electronic service tool to monitor multiplexed components.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 272 PID: SID 126 SPN: 1347 FMI: 3 Engine Fuel Pump PRessurizing Assembly 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 256 PID: PID 171 SPN: 171 FMI: 4 Ambient Air Temperature Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 249 PID: PID 171 SPN: 171 FMI: 3 Ambient Air Temperature Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 286 PID: SID 231 SPN: 639 FMI: 13 SAE J1939 Multiplexing Configuration Error- Out of Calibration

Circuit DescriptionNormally, switches, accelerators, and other components are connected to the engine control module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an original equipment manufacturer (OEM) vehicle electronic control unit (VECU) or transmission electronic control unit (ECU) in the cab. Then component values and states from components such as sensors, accelerators, and switches can be transmitted from the OEM VECU to the Cummins® ECM over the SAE J1939 data link.

Messages sent from OEM VECUs or transmission ECUs are received by the Cummins® ECM and used for controlling the engine. The Cummins® ECM and OEM VECU(s) must be configured properly, so that proper operation of the multiplexed components will occur.

Component LocationThe SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) received an invalid J1939 data link message from a multiplexed device for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The multiplexed device will not operate.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault can occur when the ECM is set up properly (components enabled and OEM VECU source addressed correctly) to receive information from an OEM VECU, but the OEM VECU is actually transmitting a message that says that component is not available for multiplexing.

It is possible to use INSITE™ electronic service tool to monitor multiplexed components.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM issue2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 285 PID: SID 231 SPN: 639 FMI: 9 SAE J1939 Multiplexing PGN Timeout Error- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 272 PID: SID 126 SPN: 1347 FMI: 3 Engine Fuel Pump PRessurizing Assembly 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 256 PID: PID 171 SPN: 171 FMI: 4 Ambient Air Temperature Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 249 PID: PID 171 SPN: 171 FMI: 3 Ambient Air Temperature Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 288 PID: PID 372 SPN: 974 FMI: 19 SAE J1939 Multiplexing Remote Accelerator Pedal or Lever Position Sensor System- Received Network Data In Error

Circuit DescriptionNormally, switches, accelerators, and other components are connected to the engine control module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an original equipment manufacturer (OEM) vehicle electronic control unit (VECU) or transmission electronic control unit (ECU) in the cab. Then component values and states from components such as sensors, accelerators, and switches can be transmitted from the OEM VECU to the Cummins® ECM over the SAE J1939 data link.

Messages sent from OEM VECUs or transmission ECUs are received by the Cummins® ECM and used for controlling the engine. The Cummins® ECM and OEM VECU(s) must be configured properly, so that proper operation of the multiplexed components will occur.

Component LocationThe SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) received a message from the OEM VECU via the J1939 data link, indicating the remote throttle signal wire or enable switch was shorted high or shorted low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.The multiplexed device will not operate.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault can occur when the OEM VECU detects an error on the remote throttle and or remote throttle enable switch. The ECM has been set up properly (components enabled and OEM VECU source addressed correctly) to receive multiplexed information for the remote throttle enable switch states and remote accelerator position over the J1939 data link from an OEM VECU, and the OEM VECU is transmitting the message for that component. Most OEM VECUs will not have the circuitry to detect a remote throttle switch error.

The two types of errors that can occur for this fault are:

The OEM VECU determines that the remote throttle signal line is shorted high or shorted low. This fault status is transmitted to the Cummins® ECM on the J1939 data link, which causes this fault to occur in the Cummins® ECM.When the remote throttle enable switch has a shorted high or shorted low error detected by the OEM VECU, this fault status is transmitted to the ECM on the J1939 data link, which causes this fault to occur in the ECM. Most OEM VECUs will not incorporate fault detection on a switch.NOTE: It is still possible to get a Fault Code 285 or 286, if there is an incorrect setup in the OEM VECU or Cummins® ECM for other components, or the remote throttle and remote throttle switch, or the data link is damaged. The OEM configurations must multiplex the remote throttle and remote throttle switch inputs together to allow the use of the J1939 multiplexing feature for these components. The INSITE™ electronic service tool can be used to monitor multiplexed components.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM issue2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 286 PID: SID 231 SPN: 639 FMI: 13 SAE J1939 Multiplexing Configuration Error- Out of Calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 285 PID: SID 231 SPN: 639 FMI: 9 SAE J1939 Multiplexing PGN Timeout Error- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 272 PID: SID 126 SPN: 1347 FMI: 3 Engine Fuel Pump PRessurizing Assembly 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 256 PID: PID 171 SPN: 171 FMI: 4 Ambient Air Temperature Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2881 PID: SID 332 SPN: 3480 FMI: 17 Aftertreatment Fuel Pressure Sensor- Data Valid But Below Normal Operational Range- Least Severe Level

Circuit DescriptionThe aftertreatment fuel pressure sensor is used to monitor the fuel pressure into the aftertreatment system. The engine control module (ECM) supplies the aftertreatment fuel pressure sensor a 5 volt reference voltage. When the fuel pressure is low, the sensor signal voltage is low. When the fuel pressure is high, the sensor signal voltage is near the 5 volt reference voltage. The ECM monitors the aftertreatment fuel pressure signal circuit voltage to calculate the pressure of the fuel within the aftertreatment system.

Component LocationThe aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the DiagnosticsThis diagnostic runs during active regeneration of the aftertreatment diesel particulate filter.

Conditions for Setting the Fault CodesThe aftertreatment fuel pressure was less than 300 kPa [43.5 psi] for more than 15 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active regeneration of the aftertreatment diesel particulate filter will be disabled unitl the next key cycle.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and perform the INSITE™ electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Plugged or restricted aftertreatment fuel supply linePlugged or restricted aftertreatment fuel shutoff manifoldPlugged or restricted pressure side fuel filterMalfunctioning fuel pump gear pump.

Possible Cause:1) Fuel filter failure2) Gear pump failure3) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2789 PID: PID 110 SPN: 110 FMI: 18 Engine Coolant Temperature- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2777 PID: SID 390 SPN: 3703 FMI: 31 Particulate Trap Active Regeneration inhibited Due to Inhibit Switch- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2771 PID: SPN: 3226 FMI: 9 Aftertreatment 1 Outlet Nox Sensor- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2764 PID: PID 131 SPN: 1209 FMI: 16 Exhaust Gas Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2754 PID: PID 81 SPN: 81 FMI: 16 Engine Diesel Particulate Filter Intake Pressure- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2739 PID: SID 237 SPN: 626 FMI: 4 Start Enable Device 1 Circuit (Ether Injection)- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 295 PID: PID 108 SPN: 108 FMI: 2 Barometric Pressure- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe barometric pressure sensor responds to pressure changes in the atmospheric pressure. The pressure changes occur based on the elevation where the engine is presently operating. The barometric pressure sensor has a 5 volt supply circuit, a sensor signal voltage, and a return circuit.

Component LocationThe barometric pressure sensor is mounted on the main branch of the engine harness near the ECM.

Conditions for Running the DiagnosticsThe first part of the diagnostic runs continuously while the keyswitch is in the ON posistion or the engine is running.The second part of the diagnostic runs at key OFF.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the barometric pressure reading was higher or lower than the other absolute pressure sensors on the engine, or an in-range malfunction of the sensor was detected.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the barometric pressure reading is used.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine, let it idle for 1 minute, and then shutdown the engine.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning barometric air pressure sensor

Possible Cause:1) ECM failure

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 288 PID: PID 372 SPN: 974 FMI: 19 SAE J1939 Multiplexing Remote Accelerator Pedal or Lever Position Sensor System- Received Network Data In Error
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 286 PID: SID 231 SPN: 639 FMI: 13 SAE J1939 Multiplexing Configuration Error- Out of Calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 285 PID: SID 231 SPN: 639 FMI: 9 SAE J1939 Multiplexing PGN Timeout Error- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 272 PID: SID 126 SPN: 1347 FMI: 3 Engine Fuel Pump PRessurizing Assembly 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2961 PID: PID 412 SPN: 412 FMI: 15 Exhaust Gas Recirculation Temperature- Data valid But Above Normal Operational Range- Least Severe Level

Circuit DescriptionThe exhaust gas recirculation (EGR) temperature sensor is a variable resistor sensor and is used to measure the temperature of the EGR gas flow after it exits the EGR cooler. The engine control module (ECM) supplies 5 volts to the EGR temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the EGR flow temperature.

The EGR temperature value is used by the ECM for the engine protection system and engine emissions control.

Component LocationThe EGR temperature sensor is located on the EGR connection tube between the EGR cooler and the air intake connection.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the EGR temperature was greater than 210°C [410°F] for more than 5 seconds.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Engine torque will be reduced.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Plugged or restricted EGR differential pressure sensor portsDamaged EGR differential pressure tubesA malfunctioning EGR valveA low reading from the EGR differential pressure sensorA low reading for the EGR valve position sensorHigh exhaust temperaturesLow coolant levelHigh coolant temperatureAn incorrect coolant/water mixtureA stuck closed variable geometry turbochargerA fouled EGR cooler.Note: This fault code will most likely not be active with no load in the shop. The engine must be loaded to trigger this fault code.

Possible Cause:1) EGR temperature sensor failure2) Coolant level3) EGR cooler failure4) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2881 PID: SID 332 SPN: 3480 FMI: 17 Aftertreatment Fuel Pressure Sensor- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2789 PID: PID 110 SPN: 110 FMI: 18 Engine Coolant Temperature- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2777 PID: SID 390 SPN: 3703 FMI: 31 Particulate Trap Active Regeneration inhibited Due to Inhibit Switch- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2771 PID: SPN: 3226 FMI: 9 Aftertreatment 1 Outlet Nox Sensor- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2764 PID: PID 131 SPN: 1209 FMI: 16 Exhaust Gas Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2754 PID: PID 81 SPN: 81 FMI: 16 Engine Diesel Particulate Filter Intake Pressure- Data Valid But Above Normal Operating range- Moderately Severe Level

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2962 PID: PID 412 SPN: 412 FMI: 16 Exhaust Gas Recirculation Temperature- Data valid But Above Normal Operational Range- Moderately Severe Level

Circuit DescriptionThe exhaust gas recirculation (EGR) temperature sensor is a variable resistor sensor and is used to measure the temperature of the EGR gas flow after it exits the EGR cooler. The engine control module (ECM) supplies 5 volts to the EGR temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the EGR flow temperature.

The EGR temperature value is used by the ECM for the engine protection system and engine emissions control.

Component LocationThe EGR temperature sensor is located on the EGR connection tube between the EGR cooler and the air intake connection.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the EGR temperature was greater than 250°C [482°F] for more than 5 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A fouled EGR coolerPlugged or restricted EGR differential pressure sensor portsA damaged EGR valveA low reading from the EGR differential pressure sensorA low reading for the EGR valve position sensorHigh exhaust temperaturesLow coolant levelHigh coolant temperatureAn incorrect coolant/water mixtureA stuck closed variable geometry turbocharger.Note: This fault code will most likely not be active with no load in the shop. The engine must be loaded to trigger this fault code.

Possible Cause:1) EGR temperature Sensor failure2) EGR cooler failure3) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2961 PID: PID 412 SPN: 412 FMI: 15 Exhaust Gas Recirculation Temperature- Data valid But Above Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2881 PID: SID 332 SPN: 3480 FMI: 17 Aftertreatment Fuel Pressure Sensor- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2789 PID: PID 110 SPN: 110 FMI: 18 Engine Coolant Temperature- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2777 PID: SID 390 SPN: 3703 FMI: 31 Particulate Trap Active Regeneration inhibited Due to Inhibit Switch- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2771 PID: SPN: 3226 FMI: 9 Aftertreatment 1 Outlet Nox Sensor- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2764 PID: PID 131 SPN: 1209 FMI: 16 Exhaust Gas Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level

Leer más →