Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2646 PID: PID 110 SPN: 110 FMI: 31 Engine Coolant Temperature- Condition Exists

Circuit DescriptionThe coolant temperature sensor is a variable resistor sensor and is used to measure the temperature of the coolant of the engine. The engine control module (ECM) supplies 5 volts to the coolant temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the coolant temperature.

Component LocationThe engine coolant temperature sensor is located on the thermostat housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine coolant temperature was above a threshold and closed the EGR valve to reduce the engine coolant temperature.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkWhen the engine coolant temperature nears the engine protection limits, the EGR valve will be closed to reduce the coolant temperature. This fault code is used as an information fault code, only indicating that the EGR valve has closed. No malfunction has occurred to cause this fault code. Other engine protection fault codes will be active if the engine coolant temperature has exceeded the engine protection limits.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2639 PID: SID 324 SPN: 3251 FMI: 15 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2638 PID: SID 380 SPN: 5298 FMI: 17 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2637 (X) PID: SID 380 SPN: 5018 FMI: 11 Aftertreatment Diesel Oxidation Catalyst face Plugged- Root Cause Not Known
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2636 PID: SID 27 SPN: 641 FMI: 9 VGT Actuator Driver Circuit- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2635 PID: SPN: 641 FMI: 31 VGT Actuator Driver Circuit- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2634 PID: SID 027 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2692 PID: SPN: 3936 FMI: 2 Aftertreatment 1 Diesel Particulate Filter System- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR outlet temperature has been above 200°C [392° F] for a calibratible period of time while the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment particulate matter sensor detected soot emissions higher than a calibrated value.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.To validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

The aftertreatment diesel particulate filter is cracked or brokenAn engine malfunction resulting in high engine out smokeMalfunctioning aftertreatment particulate matter sensor

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2646 PID: PID 110 SPN: 110 FMI: 31 Engine Coolant Temperature- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2639 PID: SID 324 SPN: 3251 FMI: 15 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2638 PID: SID 380 SPN: 5298 FMI: 17 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2637 (X) PID: SID 380 SPN: 5018 FMI: 11 Aftertreatment Diesel Oxidation Catalyst face Plugged- Root Cause Not Known
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2636 PID: SID 27 SPN: 641 FMI: 9 VGT Actuator Driver Circuit- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2635 PID: SPN: 641 FMI: 31 VGT Actuator Driver Circuit- Condition Exists

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe circuit is a pulse-width modulation (PWM) driver in the engine control module (ECM) that controls the fuel pump actuator. The actuator is grounded in the ECM. The actuator is normally open. The PWM duty cycle to the fuel pump actuator depends on the difference between desired rail pressure and sensed rail pressure.

Component LocationThe high-pressure fuel pump is mounted to the gear housing. The fuel pump actuator is mounted on the fuel pump. The fuel pressure sensor is mounted in the high pressure fuel rail. The fuel pressure relief valve is mounted on the high pressure fuel rail.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a short circuit to ground in the fuel pump actuator signal or return circuit.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Sensed fuel rail pressure will not follow the commanded rail pressure.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault becomes active when the ECM detects a short circuit in the electronic fuel pump actuator circuit. Causes for this fault code are short circuit to ground or low resistance (fuel pump actuator coil is shorted internally) in the circuit for the fuel pump actuator. When excessive current or a short circuit is detected, the ECM driver to the fuel pump actuator is turned off to protect the circuit. It is necessary to cycle the keyswitch OFF and then back ON before the ECM will test again for the cause of the fault code. The ECM driver is enabled at key ON; if the cause is no longer present, the fault code will become inactive and can be cleared. If the fault code is intermittent, look for causes of an intermittent short to ground in the wiring harness or connectors.

Fault Code 2311 can have high counts if the short circuit condition is or was intermittent.

Possible Cause:1) ECM failure2) Engine harness

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 256 PID: PID 171 SPN: 171 FMI: 4 Ambient Air Temperature Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 249 PID: PID 171 SPN: 171 FMI: 3 Ambient Air Temperature Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 242 PID: PID 84 SPN: 84 FMI: 10 Wheel-Based Vehicle Speed Sensor Circuit Tampering Has Been Detected- Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 241 PID: PID 84 SPN: 84 FMI: 2 Wheel-Based Vehicle Speed- Data Erratic, Intermittent, or Incorrect

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe circuit is a pulse-width modulation (PWM) driver in the engine control module (ECM) that controls the fuel pump actuator. The actuator is grounded in the ECM. The actuator is normally open. The PWM duty cycle to the fuel pump actuator depends on the difference between desired rail pressure and sensed rail pressure.

Component LocationThe high-pressure fuel pump is mounted to the gear housing. The fuel pump actuator is mounted on the fuel pump. The fuel pressure sensor is mounted in the high pressure fuel rail. The fuel pressure relief valve is mounted on the high pressure fuel rail.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a short circuit to ground in the fuel pump actuator signal or return circuit.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Sensed fuel rail pressure will not follow the commanded rail pressure.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault becomes active when the ECM detects a short circuit in the electronic fuel pump actuator circuit. Causes for this fault code are short circuit to ground or low resistance (fuel pump actuator coil is shorted internally) in the circuit for the fuel pump actuator. When excessive current or a short circuit is detected, the ECM driver to the fuel pump actuator is turned off to protect the circuit. It is necessary to cycle the keyswitch OFF and then back ON before the ECM will test again for the cause of the fault code. The ECM driver is enabled at key ON; if the cause is no longer present, the fault code will become inactive and can be cleared. If the fault code is intermittent, look for causes of an intermittent short to ground in the wiring harness or connectors.

Fault Code 2311 can have high counts if the short circuit condition is or was intermittent.

Possible Cause:1) ECM failure2) Engine harness

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 256 PID: PID 171 SPN: 171 FMI: 4 Ambient Air Temperature Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 249 PID: PID 171 SPN: 171 FMI: 3 Ambient Air Temperature Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 242 PID: PID 84 SPN: 84 FMI: 10 Wheel-Based Vehicle Speed Sensor Circuit Tampering Has Been Detected- Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 241 PID: PID 84 SPN: 84 FMI: 2 Wheel-Based Vehicle Speed- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2718 PID: SPN: 520325 FMI: 31 Brake and Throttle Conflict- Condition Exists

Circuit DescriptionThe accelerator pedal contains two position sensors. These position sensors are used to measure the throttle position. Both position sensors receive a 5 volt supply from the ECM. A corresponding signal voltage based on the position of the accelerator pedal is then received from the ECM. The signal voltage for accelerator position 1 is twice as much as the signal voltage from the accelerator position 2.

The accelerator position sensor is a Hall effect sensor attached to the accelerator pedal. The accelerator position sensor varies the signal voltage to the engine control module (ECM) as the accelerator pedal is depressed and released. Low signal voltage is received by the ECM when the accelerator pedal is at 0 percent. A high signal voltage is received by the ECM when the accelerator pedal is at 100 percent. The accelerator pedal position circuit contains an accelerator pedal position 5 volt supply, accelerator pedal position return, and accelerator pedal position signal.

Component LocationThe accelerator pedal or lever position sensor is mounted to the accelerator pedal assembly. Refer to the OEM service manual.

The brake pedal position switch is mounted to the brake pedal. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the vehicle is in motion, if the feature is enabled.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the accelerator pedal and brake pedal were depressed simultaneously.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The engine will have limp-home throttle control only.Conditions for Clearing the Fault CodeTo validate the repair, it may be necessary to operate the vehicle on a chassis dynamometer or to drive the vehicle.

The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code is intended to detect conditions where both the accelerator pedal and brake pedal were depressed at the same time. When this condition occurs, the accelerator pedal position is defaults to idle. If the fault occurs when both pedals are NOT depressed, this may indicate that either the accelerator pedal position or brake pedal position are NOT returning to 0 percent.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2692 PID: SPN: 3936 FMI: 2 Aftertreatment 1 Diesel Particulate Filter System- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2646 PID: PID 110 SPN: 110 FMI: 31 Engine Coolant Temperature- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2639 PID: SID 324 SPN: 3251 FMI: 15 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2638 PID: SID 380 SPN: 5298 FMI: 17 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2637 (X) PID: SID 380 SPN: 5018 FMI: 11 Aftertreatment Diesel Oxidation Catalyst face Plugged- Root Cause Not Known
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2636 PID: SID 27 SPN: 641 FMI: 9 VGT Actuator Driver Circuit- Abnormal Update Rate

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 272 PID: SID 126 SPN: 1347 FMI: 3 Engine Fuel Pump PRessurizing Assembly 1 Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe circuit is a pulse-width modulation (PWM) driver in the engine control module (ECM) that controls the fuel pump actuator. The actuator is grounded in the ECM. The actuator is normally open. The PWM duty cycle to the fuel pump actuator depends on the difference between desired rail pressure and sensed rail pressure.

Component LocationThe high-pressure fuel pump is mounted to the gear housing. The fuel pump actuator is mounted on the fuel pump. The fuel pressure sensor is mounted in the high pressure fuel rail. The fuel pressure relief valve is mounted on the high pressure fuel rail.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a short to battery, short pin-to-pin, or open circuit in the fuel pump actuator circuit.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Sensed fuel rail pressure will not follow the commanded rail pressure.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault becomes active when the ECM detects an open or short circuit in the fuel pump actuator circuit. Causes of this fault code include a short circuit to a positive voltage, open circuit, short circuit to ground, or low resistance (fuel pump actuator is shorted internally) in the fuel pump actuator circuit. If there is high harness resistance or an intermittent open circuit, Fault Code 2311 can have high inactive counts. When excessive current or a short circuit is detected, the ECM driver to the fuel pump actuator is turned off to protect the circuit. It is necessary to cycle the keyswitch OFF and then back ON before the ECM will run this diagnostic again. The ECM driver is enabled at key ON, so if the cause is no longer present, the fault code will become inactive and can be cleared.

If the fault code is intermittent, inspect the ECM connector, wiring harness, and harness connectors for loose pins and bad connections. Look closely for loose wire connections that can cause an intermittent short to ground or open circuit in the wiring harness or connectors. It may help to wiggle the harness and harness connections and watch for fault code state changes.

Possible Cause:1) ECM failure2) Engine harness

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 271 PID: SID 126 SPN: 1347 FMI: 4 Engine Fuel Pump Pressurizing Assembly 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 256 PID: PID 171 SPN: 171 FMI: 4 Ambient Air Temperature Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 249 PID: PID 171 SPN: 171 FMI: 3 Ambient Air Temperature Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 242 PID: PID 84 SPN: 84 FMI: 10 Wheel-Based Vehicle Speed Sensor Circuit Tampering Has Been Detected- Abnormal Rate of Change

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2738 PID: SID 237 SPN: 626 FMI: 3 Start Enable Device 1 Circuit (Ether Injection)- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe ether injection circuit is a device used by the engine to control the ether injection operation. The ether injection circuit utilizes a Pulse Width Modulated (PWM) signal. A PWM signal is pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

Component LocationThe control solenoid location varies by OEM. Refer to the appropriate OEM service manual to determine the location.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault CodesThe ether injection circuit pulse width modulated (PWM) signal detected a voltage greater than 0-VDC when the PWM signal was turned off by the ECM.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The ether injection operation will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

An open circuit in the engine harness or ether injection solenoidA short circuit to voltage source in the OEM harnessA malfunctioning ECM.

Possible Cause:1) Ether injection solenoid failure2) OEM harness3) ECM failure

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2718 PID: SPN: 520325 FMI: 31 Brake and Throttle Conflict- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2692 PID: SPN: 3936 FMI: 2 Aftertreatment 1 Diesel Particulate Filter System- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2646 PID: PID 110 SPN: 110 FMI: 31 Engine Coolant Temperature- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2639 PID: SID 324 SPN: 3251 FMI: 15 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2638 PID: SID 380 SPN: 5298 FMI: 17 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2637 (X) PID: SID 380 SPN: 5018 FMI: 11 Aftertreatment Diesel Oxidation Catalyst face Plugged- Root Cause Not Known

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2739 PID: SID 237 SPN: 626 FMI: 4 Start Enable Device 1 Circuit (Ether Injection)- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe ether injection circuit is a device used by the engine to control the ether injection operation. The ether injection circuit utilizes a Pulse Width Modulated (PWM) signal. A PWM signal is pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

Component LocationThe control solenoid location varies by OEM. Refer to the appropriate OEM service manual to determine the location.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault CodesThe ether injection circuit pulse width modulated (PWM) signal was not system voltage when the PWM signal was turned ON.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The ether injection operation will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code is logged when the ECM commands 12-VDC to the ether injection solenoid, but the voltage on the ether injection signal circuit is less than 12-VDC. The low voltage on the signal circuit usually indicates a short circuit to ground in the harness or solenoid.

Possible Cause:1) Ether Injection Solenoid failure2) OEM harness3) ECM failure

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2738 PID: SID 237 SPN: 626 FMI: 3 Start Enable Device 1 Circuit (Ether Injection)- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2718 PID: SPN: 520325 FMI: 31 Brake and Throttle Conflict- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2692 PID: SPN: 3936 FMI: 2 Aftertreatment 1 Diesel Particulate Filter System- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2646 PID: PID 110 SPN: 110 FMI: 31 Engine Coolant Temperature- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2639 PID: SID 324 SPN: 3251 FMI: 15 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2638 PID: SID 380 SPN: 5298 FMI: 17 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Least Severe Level

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2754 PID: PID 81 SPN: 81 FMI: 16 Engine Diesel Particulate Filter Intake Pressure- Data Valid But Above Normal Operating range- Moderately Severe Level

Circuit DescriptionThe engine aftertreatment system monitors the soot load in the aftertreatment diesel particulate filter. Under normal operating conditions, the aftertreatment diesel particulate filter is self-cleaning, where soot is converted to carbon dioxide, nitrogen, and water. Under light load operating conditions, it can be necessary to perform a stationary regeneration of the aftertreatment diesel particulate filter. The soot load in the aftertreatment diesel particulate filter is estimated, using the aftertreatment differential pressure sensor and the calculated soot output of the engine.

Component LocationThe aftertreatment diesel particulate filter is located in the exhaust system and is installed by the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesSoot accumulation within the diesel particulate filter occurred at a higher rate than under normal operating conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeThe fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.

Shop TalkPossible causes of this fault code include:

Boost leaks in the charge-air cooler plumbingA malfunction of the variable geometry turbocharger (VGT)A malfunction of the exhaust gas recirculation (EGR) valveA malfunctioning in-range EGR differential pressure sensorA malfunctioning in-range boost pressure sensorA malfunctioning in-range barometric pressure sensorA cylinder misfire or overfueling.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Charge-air cooler failure2) Barometric pressure sensor failure3) Intake manifold pressure sensor failure4) Exhaust manifold pressure sensor failure5) Aftertreatment DPF differential pressure sensor failure6) Fuel rail pressure relief valve failure7) Loose injector high-pressure connector(s)8) High-pressure connector failure9) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2739 PID: SID 237 SPN: 626 FMI: 4 Start Enable Device 1 Circuit (Ether Injection)- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2738 PID: SID 237 SPN: 626 FMI: 3 Start Enable Device 1 Circuit (Ether Injection)- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2718 PID: SPN: 520325 FMI: 31 Brake and Throttle Conflict- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2692 PID: SPN: 3936 FMI: 2 Aftertreatment 1 Diesel Particulate Filter System- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2646 PID: PID 110 SPN: 110 FMI: 31 Engine Coolant Temperature- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2639 PID: SID 324 SPN: 3251 FMI: 15 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Least Severe Level

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2764 PID: PID 131 SPN: 1209 FMI: 16 Exhaust Gas Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the engine control module (ECM) to control emissions and exhaust gas recirculation (EGR) valve operation. The ECM provides a 5 volt supply to the exhaust gas pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The exhaust gas pressure sensor provides a signal to the ECM on the exhaust gas pressure sensor signal circuit. This sensor signal voltage changes, based on the pressure in the exhaust manifold.

Component LocationThe exhaust gas pressure sensor is located above the front section of the exhaust manifold and is plumbed into the exhaust manifold.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesExhaust gas pressure sensor reading was greater that the engine protection limits.

Action Taken When the Fault Code is ActiveAn engine derate will be activated to bring exhaust gas pressure below the maximum operating limits.

Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning variable geometry turbochargerA damaged in-range exhaust gas pressure sensorA plugged or restricted aftertreatment diesel particulate filterA plugged or restricted EGR cooler.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2754 PID: PID 81 SPN: 81 FMI: 16 Engine Diesel Particulate Filter Intake Pressure- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2739 PID: SID 237 SPN: 626 FMI: 4 Start Enable Device 1 Circuit (Ether Injection)- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2738 PID: SID 237 SPN: 626 FMI: 3 Start Enable Device 1 Circuit (Ether Injection)- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2718 PID: SPN: 520325 FMI: 31 Brake and Throttle Conflict- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2692 PID: SPN: 3936 FMI: 2 Aftertreatment 1 Diesel Particulate Filter System- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2646 PID: PID 110 SPN: 110 FMI: 31 Engine Coolant Temperature- Condition Exists

Leer más →