Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 596 PID: PID 167 SPN: 167 FMI: 16 Electrical Charging System Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level

Circuit DescriptionThe engine control module (ECM) receives constant voltage from the batteries through the unswitched battery wires that are connected directly to the positive (+) battery post. The ECM receives switched battery input through the vehicle keyswitch wire when the vehicle keyswitch is turned ON.

Component LocationThe ECM is connected to the battery by the OEM harness. This direct link provides a constant power supply for the ECM. The location of the battery will vary with the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the battery voltage was greater than a calibratible value.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code is part of the Battery Voltage Monitor feature. The ECM can increase idle speed and deactivate idle decrement switch if idle speedup is enabled. Use INSITE™ electronic service tool to view the Battery Voltage Monitor feature settings. Disabling the Battery Voltage Monitor feature will also disable this fault code.

Make sure the ECM battery supply (+) is coming directly from the battery and not the starter.

Possible cause of this fault code:

Overcharged batteries caused by a malfunctioning alternator or regulator.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Battery failure2) Alternator, Regulator, OEM wiring to the Alternator failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 595 PID: PID 103 SPN: 103 FMI: 16 Turbocharger 1 Speed- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 585 PID: SID 39 SPN: 677 FMI: 4 Starter Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 584 PID: SID 39 SPN: 677 FMI: 3 Starter Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 559 PID: PID 157 SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 556 PID: PID 101 SPN: 101 FMI: 0 Crankcase Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 555 PID: PID 101 SPN: 101 FMI: 16 Crankcase Pressure- Data Valid But Above Normal Operational Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 597 PID: PID 167 SPN: 167 FMI: 18 Electrical Charging System Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level

Circuit DescriptionThe engine control module (ECM) receives constant voltage from the batteries through the unswitched battery wires that are connected directly to the positive (+) battery post. The ECM receives switched battery input through the vehicle keyswitch wire when the vehicle keyswitch is turned ON.

Component LocationThe ECM is connected to the battery by the OEM harness. This direct link provides a constant power supply for the ECM. The location of the battery will vary with the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the battery voltage was less than a calibratible value.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code is part of the Battery Voltage Monitor feature. The ECM can increase idle speed and deactivate idle decrement switch if Idle Speedup is enabled. Use INSITE™ electronic service tool to view the Battery Voltage Monitor feature settings. Disabling the Battery Voltage Monitor feature will also disable this fault code.

Make sure the ECM unswitched battery supply is coming directly from the battery and not the starter.

Possible causes of this fault code include:

Undercharged batteries caused by a malfunctioning alternator or regulator.High-current devices on the vehicle such as citizens band radio amplifiers, numerous exterior lights, or other accessories.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Battery Failure2) Alternator, or OEM wiring to the Alternator failure3) Battery Harness failure4) OEM power harness5) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 596 PID: PID 167 SPN: 167 FMI: 16 Electrical Charging System Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 595 PID: PID 103 SPN: 103 FMI: 16 Turbocharger 1 Speed- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 585 PID: SID 39 SPN: 677 FMI: 4 Starter Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 584 PID: SID 39 SPN: 677 FMI: 3 Starter Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 559 PID: PID 157 SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 556 PID: PID 101 SPN: 101 FMI: 0 Crankcase Pressure- Data Valid But Above Normal Operating Range- Most Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6254 PID: SPN: 5246 FMI: 16 Aftertreatment SCR Operator Inducement Severity- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe ECM continuously monitors the engine’s fault code status to determine if any fault codes critical to successful engine operation are active.

Component LocationThe ECM mounting location varies, depending on the engine model, and may be mounted either on or off the engine.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected certain critical fault codes related to engine operation were active and the engine continued to operate.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Engine torque will be reduced.Conditions for Clearing the Fault CodeThis fault code will go inactive once all other active fault codes have been addressed. Refer to the appropriate fault code troubleshooting tree.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.

Shop TalkThis fault code is for information only, and indicates that an engine power derate has been implemented in order to make sure that the critical fault codes that are presently active in the ECM are addressed as quickly as possible.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5882 PID: SPN: 3464 FMI: 7 Electronic Throttle Control Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5881 PID: SPN: 3464 FMI: 4 Electronic Throttle Control Actuator Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5879 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5868 PID: SPN: 4339 FMI: 7 Aftertreatment 1 SCR Feedback Control Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5837 PID: SPN: 5835 FMI: 21 Aftertreatment 1 Particulate Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5793 PID: SPN: 7323 FMI: 3 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6255 PID: SPN: 1569 FMI: 15 Engine Protection Torque Derate- Data Valid But Above Normal Operating Range- Least Severe Level

Circuit DescriptionThe ECM continuously monitors the engine’s fault code status to determine if any fault codes critical to successful engine operation are active.

Component LocationThe ECM mounting location varies, depending on the engine model, and may be mounted either on or off the engine.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected certain critical fault codes related to engine operation were active and the engine continued to operate.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Engine torque will be reduced.Conditions for Clearing the Fault CodeThis fault code will go inactive once all other active fault codes have been addressed. Refer to the appropriate fault code troubleshooting tree.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.

Shop TalkThis fault code is for information only, and indicates that an engine power derate has been implemented in order to make sure that the critical fault codes that are presently active in the ECM are addressed as quickly as possible.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6254 PID: SPN: 5246 FMI: 16 Aftertreatment SCR Operator Inducement Severity- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5882 PID: SPN: 3464 FMI: 7 Electronic Throttle Control Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5881 PID: SPN: 3464 FMI: 4 Electronic Throttle Control Actuator Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5879 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5868 PID: SPN: 4339 FMI: 7 Aftertreatment 1 SCR Feedback Control Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5837 PID: SPN: 5835 FMI: 21 Aftertreatment 1 Particulate Sensor- Data Not Rational- Drifted Low

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6256 PID: SPN: 168 FMI: 15 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Least Severe Level

Circuit DescriptionThe engine control module (ECM) receives constant voltage from the batteries through the unswitched battery wires that are connected directly to the positive (+) battery post. The ECM receives switched battery input through the keyswitch wire when the keyswitch is turned ON.

Component LocationThe ECM is connected to the battery by the OEM harness. This direct link provides a constant power supply for the ECM. The location of the battery will vary with the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected excessive battery supply voltage.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkFaulty alternator or regulator that is overcharging the systemBatteries connected in series instead of parallelIncorrect jump-starting procedure.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Battery System2) Alternator, regulator, OEM wiring to alternator failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6255 PID: SPN: 1569 FMI: 15 Engine Protection Torque Derate- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6254 PID: SPN: 5246 FMI: 16 Aftertreatment SCR Operator Inducement Severity- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5882 PID: SPN: 3464 FMI: 7 Electronic Throttle Control Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5881 PID: SPN: 3464 FMI: 4 Electronic Throttle Control Actuator Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5879 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5868 PID: SPN: 4339 FMI: 7 Aftertreatment 1 SCR Feedback Control Status- Mechanical System Not Responding or Out of Adjustment

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6257 PID: SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level

Circuit DescriptionThe engine control module (ECM) receives constant voltage from the batteries through the unswitched battery wires that are connected directly to the positive (+) battery post. The ECM receives switched battery input through the keyswitch wire when the keyswitch is turned ON.

Component LocationThe ECM is connected to the battery by the OEM harness. This direct link provides a constant power supply for the ECM. The location of the battery will vary with the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected low battery supply voltage.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkVerify that the ECM unswitched power supply is coming from the batteries and not the starter or other device. Check for possible weak batteries.If the ECM unswitched battery supply is taken from the starter, check for low voltage during cranking. Low voltage during cranking can cause the ECM power supply to drop below specifications and log Fault Code 441.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Loose Connections2) Battery failure3) Fuses4) OEM power harness5) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6256 PID: SPN: 168 FMI: 15 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6255 PID: SPN: 1569 FMI: 15 Engine Protection Torque Derate- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6254 PID: SPN: 5246 FMI: 16 Aftertreatment SCR Operator Inducement Severity- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5882 PID: SPN: 3464 FMI: 7 Electronic Throttle Control Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5881 PID: SPN: 3464 FMI: 4 Electronic Throttle Control Actuator Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5879 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6258 PID: SPN: 1075 FMI: 3 Electric Lift Pump For Engine Fuel Supply- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe fuel lift pump circuit is a discrete output in the engine control module (ECM) that controls the electric fuel lift pump. The lift pump is grounded in the ECM.

Component LocationThe fuel lift pump is mounted on the intake side of the engine.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and the lift pump timer has expired 1 minute after initial key ON.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the fuel lift pump signal circuit was detected to be greater than 0-VDC when the signal was turned off by the engine control module (ECM).

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodePerform a key cycle, and leave the key switch in the ON position for at least 2 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

An open circuit in the engine harnessA short circuit to battery in the engine harness.A malfunctioning fuel lift pump

Possible Cause:1) Electric fuel lift pump failure2) Engine harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6257 PID: SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6256 PID: SPN: 168 FMI: 15 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6255 PID: SPN: 1569 FMI: 15 Engine Protection Torque Derate- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6254 PID: SPN: 5246 FMI: 16 Aftertreatment SCR Operator Inducement Severity- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5882 PID: SPN: 3464 FMI: 7 Electronic Throttle Control Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5881 PID: SPN: 3464 FMI: 4 Electronic Throttle Control Actuator Driver Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6259 PID: SPN: 1075 FMI: 4 Electric Lift Pump For Engine Fuel Supply- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe fuel lift pump circuit is a discrete output in the engine control module (ECM) that controls the electric fuel lift pump. The lift pump is grounded in the ECM.

Component LocationThe fuel lift pump is mounted on the intake side of the engine.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is initially turned to the ON position.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the fuel lift pump signal circuit was detected to be 0-VDC when the signal is turned ON by the engine control module (ECM).

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A short circuit to ground in the engine harnessA malfunctioning fuel lift pump

Possible Cause:1) Electric Fuel lift pump failure2) Engine harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6258 PID: SPN: 1075 FMI: 3 Electric Lift Pump For Engine Fuel Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6257 PID: SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6256 PID: SPN: 168 FMI: 15 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6255 PID: SPN: 1569 FMI: 15 Engine Protection Torque Derate- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6254 PID: SPN: 5246 FMI: 16 Aftertreatment SCR Operator Inducement Severity- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5882 PID: SPN: 3464 FMI: 7 Electronic Throttle Control Actuator- Mechanical System Not Responding or Out of Adjustment

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6261 PID: SPN: 677 FMI: 3 Engine Starter Motor Relay Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe starter lockout relay is controlled by the engine control module (ECM) through the starter lockout relay signal circuit. The relay prevents the starter from being engaged when the engine is running. The relay return circuit is dependent on OEM wiring. It can be wired back to the ECM on some vehicles or wired to chassis or block ground on others. Consult the OEM wiring diagram for return circuit details. The starter lockout relay circuit utilizes a pulse width modulated (PWM) signal. A PWM signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

Component LocationThe starter lockout relay is installed by the vehicle OEM. Refer to the OEM service manual for component location.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the starter lockout relay pulse width modulated (PWM) signal was NOT at system voltage when the pulse width modulated (PWM) signal was commanded ON.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.The Starter Lockout feature will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe ECM monitors the voltage level on this circuit. If it detects a voltage when the signal is commanded off, it records this fault code. This fault code can be caused by:

Open circuit in the starter lockout relay, OEM harness, or connectorsShort circuit to a voltage source in the OEM harness or relay.This fault can also be set active if the over crank protection feature (starter lockout) is enabled, but the engine/ECM is not wired to support it.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Starter Lockout relay failure2) OEM harness3) ECM Failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6259 PID: SPN: 1075 FMI: 4 Electric Lift Pump For Engine Fuel Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6258 PID: SPN: 1075 FMI: 3 Electric Lift Pump For Engine Fuel Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6257 PID: SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6256 PID: SPN: 168 FMI: 15 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6255 PID: SPN: 1569 FMI: 15 Engine Protection Torque Derate- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6254 PID: SPN: 5246 FMI: 16 Aftertreatment SCR Operator Inducement Severity- Data Valid But Above Normal Operating Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6262 PID: SPN: 677 FMI: 4 Engine Starter Motor Relay Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe starter lockout relay is controlled by the engine control module (ECM) through the starter lockout relay signal circuit. The relay prevents the starter from being engaged when the engine is running. The relay return circuit is dependent on OEM wiring. It can be wired back to the ECM on some vehicles or wired to chassis or block ground on others. Consult the OEM wiring diagram for return circuit details. The starter lockout relay circuit utilizes a pulse width modulated (PWM) signal. A PWM signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

Component LocationThe starter lockout relay is installed by the vehicle OEM. Refer to the OEM service manual for component location.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the starter lockout relay pulse width modulated (PWM) signal was at system voltage when the pulse width modulated (PWM) signal was commanded OFF.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.The Starter Lockout feature will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe ECM monitors the voltage level on this circuit. If it detects a low voltage when the signal is commanded ON, it records this fault code. This fault code can be caused by a short circuit to ground in the starter lockout relay, OEM harness, or connectors.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Starter Lockout Relay failure2) Starter Lockout Relay3) OEM harness4) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6261 PID: SPN: 677 FMI: 3 Engine Starter Motor Relay Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6259 PID: SPN: 1075 FMI: 4 Electric Lift Pump For Engine Fuel Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6258 PID: SPN: 1075 FMI: 3 Electric Lift Pump For Engine Fuel Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6257 PID: SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6256 PID: SPN: 168 FMI: 15 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6255 PID: SPN: 1569 FMI: 15 Engine Protection Torque Derate- Data Valid But Above Normal Operating Range- Least Severe Level