Ir directamente al contenido Ir directamente al menú lateral

Cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6263 PID: SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe fan control circuit is a device used by the engine to control the fan operation. When the engine control module (ECM) energizes the fan control circuit, the engine fan is engaged.

The fan control circuit utilizes a pulse width modulated (PWM) signal. A PWM signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

There are two types of fans supported by the fan control circuit; variable speed and ON/OFF. INSITE™ electronic service tool can be used to determine which fan type is currently set up for use. The fan control circuit varies by original equipment manufacturer (OEM). Certain OEMs can use a solenoid return that is wired to the ECM or can use a return that goes to the engine block or chassis ground.

Component LocationThe control solenoid location varies by OEM. Refer to the appropriate OEM service manual to determine the location.

Conditions for Running the DiagnosticsFor ON/OFF and variable speed fan types, the diagnostic runs when the fan is turned off and will latch active when the fan PWM signal is 100 percent. For all other fan types, the diagnostic runs when the fan PWM signal is less than 100 percent and will latch active when the fan PWM signal is 100 percent.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the fan control circuit pulse width modulated (PWM) signal voltage was greater then 0-VDC when the PWM signal was commanded OFF.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Fan operation will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf Fault Code 2377 is still active after completing all the steps in this fault code troubleshooting tree, consult the OEM service literature for procedures to check the fan clutch device for an open circuit or short circuit to ground.

Possible causes of this fault include:

An open circuit in the harness or fan control solenoid.A short circuit to voltage source in the OEM harness.A malfunctioning ECM.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Fan Control Solenoid failure2) OEM harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6262 PID: SPN: 677 FMI: 4 Engine Starter Motor Relay Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6261 PID: SPN: 677 FMI: 3 Engine Starter Motor Relay Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6259 PID: SPN: 1075 FMI: 4 Electric Lift Pump For Engine Fuel Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6258 PID: SPN: 1075 FMI: 3 Electric Lift Pump For Engine Fuel Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6257 PID: SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6256 PID: SPN: 168 FMI: 15 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Least Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6264 PID: SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe fan control circuit is a device used by the engine to control the fan operation. When the engine control module (ECM) energizes the fan control circuit, the engine fan is engaged.

The fan control circuit utilizes a pulse width modulated (PWM) signal. A PWM signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

There are two types of fans supported by the fan control circuit; variable speed and ON/OFF. INSITE™ electronic service tool can be used to determine which fan type is presently set up for use. The fan control circuit varies by the OEM. OEMs can use a solenoid return that is wired to the ECM or use a return that goes to engine block or chassis ground.

Component LocationThe control solenoid location varies by OEM. Refer to the appropriate OEM service manual to determine the location.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the fan control circuit pulse width modulated (PWM) signal was not at system voltage when the pulse width modulated (PWM) signal was commanded ON.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Fan operation will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe fan control logic can be adjusted with INSITE™ electronic service tool. There are two choices: 12 or 24 volts ON, or 0 volts ON. For proper fan operation, the fan control logic setup with INSITE™ electronic service tool must match the hardware configuration on the vehicle.

This fault code is logged when the ECM commands 12 or 24-VDC to the fan control solenoid, but the voltage on the fan control signal circuit is less than 12 or 24-VDC. The low voltage on the signal circuit usually indicates a short circuit to ground in the harness or solenoid.

If Fault Code 6264 is still active after completing the following troubleshooting steps, consult the OEM service manual for procedures to check the fan control circuit for a short circuit to ground.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Fan control solenoid failure2) OEM harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6263 PID: SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6262 PID: SPN: 677 FMI: 4 Engine Starter Motor Relay Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6261 PID: SPN: 677 FMI: 3 Engine Starter Motor Relay Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6259 PID: SPN: 1075 FMI: 4 Electric Lift Pump For Engine Fuel Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6258 PID: SPN: 1075 FMI: 3 Electric Lift Pump For Engine Fuel Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6257 PID: SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6265 PID: SPN: 3936 FMI: 7 Aftertreatment 1 Diesel Particulate Filter System- Mechanical System Not Responding or Out of Adjustment

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel particulate filter is located in the exhaust system and is installed by the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment diesel particulate filter outlet temperature sensor reading was greater than 950°C [1742°F] for 30 seconds, or the difference between the diesel particulate filter intake temperature and the diesel particulate filter outlet temperature was greater than 1050°C [1922°F] for 30 seconds.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Excessive engine oil or diesel fuel being introduced into the exhaust system from the engineA malfunctioning engine fuel injector causing unburned diesel fuel to enter the exhaust systemA face plugged aftertreatment diesel oxidation catalystReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6264 PID: SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6263 PID: SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6262 PID: SPN: 677 FMI: 4 Engine Starter Motor Relay Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6261 PID: SPN: 677 FMI: 3 Engine Starter Motor Relay Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6259 PID: SPN: 1075 FMI: 4 Electric Lift Pump For Engine Fuel Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6258 PID: SPN: 1075 FMI: 3 Electric Lift Pump For Engine Fuel Supply- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6266 PID: SPN: 5862 FMI: 14 Aftertreatment 1 SCR Intermediate Gas Temperature- Special Instructions

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the engine is running and exhaust flow is above a minimum level.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment SCR intermediate temperature sensor signal was irrational for more than 5 minutes.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, it may be necessary to operate the vehicle on a chassis dynamometer or to drive the vehicle in order to get the engine load high enough for the diagnostic to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR intermediate temperature sensorA malfunctioning aftertreatment SCR outlet temperature sensor

A malfunctioning aftertreatment SCR outlet temperature sensor

Possible Cause:1) Aftertreatment Selective Catalytic reduction temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6265 PID: SPN: 3936 FMI: 7 Aftertreatment 1 Diesel Particulate Filter System- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6264 PID: SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6263 PID: SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6262 PID: SPN: 677 FMI: 4 Engine Starter Motor Relay Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6261 PID: SPN: 677 FMI: 3 Engine Starter Motor Relay Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6259 PID: SPN: 1075 FMI: 4 Electric Lift Pump For Engine Fuel Supply- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6267 PID: SPN: 4360 FMI: 14 Aftertreatment 1 SCR Intake Temperature- Special Instructions

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the engine is running and exhaust flow is above a minimum level.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment SCR intermediate temperature sensor signal was irrational for more than 5 minutes.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, it may be necessary to operate the vehicle on a chassis dynamometer or to drive the vehicle in order to get the engine load high enough for the diagnostic to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR intermediate temperature sensorA malfunctioning aftertreatment SCR outlet temperature sensor

Possible Cause:1) Aftertreatment SCR temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6266 PID: SPN: 5862 FMI: 14 Aftertreatment 1 SCR Intermediate Gas Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6265 PID: SPN: 3936 FMI: 7 Aftertreatment 1 Diesel Particulate Filter System- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6264 PID: SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6263 PID: SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6262 PID: SPN: 677 FMI: 4 Engine Starter Motor Relay Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6261 PID: SPN: 677 FMI: 3 Engine Starter Motor Relay Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6268 PID: SPN: 4363 FMI: 12 Aftertreatment 1 SCR Outlet Temperature Sensor- Bad Intelligent Device or Component

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment SCR temperature sensor module reported the aftertreatment SCR outlet temperature signal was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR outlet temperature sensor

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment SCR temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6267 PID: SPN: 4360 FMI: 14 Aftertreatment 1 SCR Intake Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6266 PID: SPN: 5862 FMI: 14 Aftertreatment 1 SCR Intermediate Gas Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6265 PID: SPN: 3936 FMI: 7 Aftertreatment 1 Diesel Particulate Filter System- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6264 PID: SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6263 PID: SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6262 PID: SPN: 677 FMI: 4 Engine Starter Motor Relay Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 629 PID: PID 314 SPN: 1176 FMI: 18 Turbocharger 1 Compressor Inlet Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe ECM calculates a differential pressure across the turbocharger using the intake manifold pressure sensor and the crankcase pressure sensor.

Component LocationThe intake manifold pressure sensor is located in the air intake horn. The crankcase pressure sensor is mounted to the crankcase breather filter housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the calculated differential pressure across the turbocharger was greater than a threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Plugged or restricted air filter pluggedRestricted crankcase breather filter pluggedRestricted crankcase breather plumbing.

Possible Cause:1) Intake Manifold temperature/pressure Sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 597 PID: PID 167 SPN: 167 FMI: 18 Electrical Charging System Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 596 PID: PID 167 SPN: 167 FMI: 16 Electrical Charging System Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 595 PID: PID 103 SPN: 103 FMI: 16 Turbocharger 1 Speed- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 585 PID: SID 39 SPN: 677 FMI: 4 Starter Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 584 PID: SID 39 SPN: 677 FMI: 3 Starter Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 559 PID: PID 157 SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6336 PID: SPN: 862 FMI: 3 Crankcase Breather Filter Heater Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe crankcase breather heater is used to keep the crankcase breather filter housing from freezing. The ECM supplies battery voltage to the breather heater when heating is commanded.

Component LocationThe crankcase breather heater is mounted to the crankcase breather filter housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the crankcase breather heater signal voltage was out of range high for more than 10 seconds.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.The crankcase breather heater will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Short circuit to voltage in the crankcase breather heater circuitMalfunctioning ECM.

Possible Cause:1) Engine harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6268 PID: SPN: 4363 FMI: 12 Aftertreatment 1 SCR Outlet Temperature Sensor- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6267 PID: SPN: 4360 FMI: 14 Aftertreatment 1 SCR Intake Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6266 PID: SPN: 5862 FMI: 14 Aftertreatment 1 SCR Intermediate Gas Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6265 PID: SPN: 3936 FMI: 7 Aftertreatment 1 Diesel Particulate Filter System- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6264 PID: SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6263 PID: SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6337 PID: SPN: 862 FMI: 4 Crankcase Breather Filter Heater Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe crankcase breather heater is used to keep the crankcase breather filter housing from freezing. The ECM supplies battery voltage to the breather heater when heating is commanded.

Component LocationThe crankcase breather heater is mounted to the crankcase breather filter housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the crankcase breather heater signal circuit was shorted to ground.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.The crankcase breather heater will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Open crankcase breather heater circuitShort circuit to ground in the crankcase breather heater circuitMalfunctioning ECM.

Possible Cause:1) Crankcase breather heater failure2) Engine harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6336 PID: SPN: 862 FMI: 3 Crankcase Breather Filter Heater Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6268 PID: SPN: 4363 FMI: 12 Aftertreatment 1 SCR Outlet Temperature Sensor- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6267 PID: SPN: 4360 FMI: 14 Aftertreatment 1 SCR Intake Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6266 PID: SPN: 5862 FMI: 14 Aftertreatment 1 SCR Intermediate Gas Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6265 PID: SPN: 3936 FMI: 7 Aftertreatment 1 Diesel Particulate Filter System- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6264 PID: SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6339 PID: SPN: 96 FMI: 9 Fuel Level 1- Abnormal Update Rate

Circuit DescriptionNormally, switches, accelerators, and other components are connected to the engine control module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an original equipment manufacturer (OEM) vehicle electronic control unit (VECU) or transmission electronic control unit (ECU) in the cab. Then component values and states from components such as sensors, accelerators, and switches can be transmitted from the OEM VECU to the Cummins® ECM over the SAE J1939 data link.

Messages sent from OEM VECUs or transmission ECUs are received by the Cummins® ECM and used for controlling the engine. The Cummins® ECM and OEM VECU(s) must be configured properly, so that proper operation of the multiplexed components will occur.

Component LocationThe SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) did not receive a message from a multiplexed device.

The Engine Control Module (ECM) detected an open or short circuit condition in the J1939 data link harness.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The multiplexed device will not operate.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkWhen this fault code is active, some multiplexed devices can possibly not function as desired.

This fault can occur for the following reasons:

When the ECM is set up properly (components enabled and OEM VECU source addressed correctly) to receive information from an OEM VECU, but the OEM VECU is actually transmitting a message that says that component is not available for multiplexing. This can be caused when a multiplexed component is enabled in the ECM, but the OEM VECU source address of the VECU transmitting the component message is incorrect in the Cummins® ECM, or the OEM VECU is not set up to transmit the multiplexed component message.This fault can also be caused by a damaged J1939 data link connection between the OEM VECU and Cummins® ECM, a damaged connection between the component and the OEM VECU, damaged OEM VECU or damaged Cummins® ECM. It can become necessary to contact the OEM for proper multiplexing configuration.It is possible to use INSITE™ electronic service tool to monitor multiplexed components.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6337 PID: SPN: 862 FMI: 4 Crankcase Breather Filter Heater Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6336 PID: SPN: 862 FMI: 3 Crankcase Breather Filter Heater Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6268 PID: SPN: 4363 FMI: 12 Aftertreatment 1 SCR Outlet Temperature Sensor- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6267 PID: SPN: 4360 FMI: 14 Aftertreatment 1 SCR Intake Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6266 PID: SPN: 5862 FMI: 14 Aftertreatment 1 SCR Intermediate Gas Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6265 PID: SPN: 3936 FMI: 7 Aftertreatment 1 Diesel Particulate Filter System- Mechanical System Not Responding or Out of Adjustment

Leer más →