Ir directamente al contenido Ir directamente al menú lateral

Cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5579 PID: SPN: 6778 FMI: 16 Aftertreatment 1 Particulate Sensor Power Supply- Data Valid But Above Normal Operating range- Moderately Severe Level

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment particulate sensor assembly

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5578 PID: SPN: 6778 FMI: 4 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5577 PID: SPN: 6778 FMI: 3 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5383 PID: SPN: 3720 FMI: 15 Aftertreatment 1 Diesel Particulate Filter Ash Load Percent- Data valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5298 PID: SPN: 747 FMI: 19 Engine/transmission Match- Received Network Data in Error
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5297 PID: SPN: 747 FMI: 13 Engine/transmission Match- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5278 PID: SPN: 6802 FMI: 31 Aftertreatment 1 Diesel Exhaust Fluid Dosing System Frozen- Condition Exists

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5581 PID: SPN: 7329 FMI: 2 Aftertreatment 1 Particulate Sensor Heater Power Supply- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment particulate sensor assembly

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5579 PID: SPN: 6778 FMI: 16 Aftertreatment 1 Particulate Sensor Power Supply- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5578 PID: SPN: 6778 FMI: 4 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5577 PID: SPN: 6778 FMI: 3 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5383 PID: SPN: 3720 FMI: 15 Aftertreatment 1 Diesel Particulate Filter Ash Load Percent- Data valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5298 PID: SPN: 747 FMI: 19 Engine/transmission Match- Received Network Data in Error
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5297 PID: SPN: 747 FMI: 13 Engine/transmission Match- Out of Calibration

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5582 PID: SPN: 7854 FMI: 2 Aftertreatment 1 Particulate Sensor Module Battery Voltage Supply- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe power supply to the aftertreatment particulate sensor has been intermittently interrupted.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Damaged wiring harnessMalfunctioning aftertreatment particulate matter sensor

Possible Cause:1) Loose Connections2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5581 PID: SPN: 7329 FMI: 2 Aftertreatment 1 Particulate Sensor Heater Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5579 PID: SPN: 6778 FMI: 16 Aftertreatment 1 Particulate Sensor Power Supply- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5578 PID: SPN: 6778 FMI: 4 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5577 PID: SPN: 6778 FMI: 3 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5383 PID: SPN: 3720 FMI: 15 Aftertreatment 1 Diesel Particulate Filter Ash Load Percent- Data valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5298 PID: SPN: 747 FMI: 19 Engine/transmission Match- Received Network Data in Error

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5583 PID: SPN: 6777 FMI: 10 Aftertreatment 1 Particulate Sensor Detection Status- Abnormal Rate of Change

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment particulate matter sensor reading was not valid.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensorFor intermittent power supply and data link communication issues with aftertreatment components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing, or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5582 PID: SPN: 7854 FMI: 2 Aftertreatment 1 Particulate Sensor Module Battery Voltage Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5581 PID: SPN: 7329 FMI: 2 Aftertreatment 1 Particulate Sensor Heater Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5579 PID: SPN: 6778 FMI: 16 Aftertreatment 1 Particulate Sensor Power Supply- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5578 PID: SPN: 6778 FMI: 4 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5577 PID: SPN: 6778 FMI: 3 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5383 PID: SPN: 3720 FMI: 15 Aftertreatment 1 Diesel Particulate Filter Ash Load Percent- Data valid But Above Normal Operating Range- Least Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5584 PID: SPN: 6773 FMI: 7 Aftertreatment 1 Particulate Sensor Regeneration Status- Mechanical System Not Responding or Out of Adjustment

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment particulate matter sensor heater was unable to maintain sensor regeneration temperature for a calibrated period of time.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5583 PID: SPN: 6777 FMI: 10 Aftertreatment 1 Particulate Sensor Detection Status- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5582 PID: SPN: 7854 FMI: 2 Aftertreatment 1 Particulate Sensor Module Battery Voltage Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5581 PID: SPN: 7329 FMI: 2 Aftertreatment 1 Particulate Sensor Heater Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5579 PID: SPN: 6778 FMI: 16 Aftertreatment 1 Particulate Sensor Power Supply- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5578 PID: SPN: 6778 FMI: 4 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5577 PID: SPN: 6778 FMI: 3 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 559 PID: PID 157 SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the fuel rail pressure sensor using a dedicated sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The fuel rail pressure sensor provides a primary fuel pressure signal to the ECM on the fuel rail pressure sensor signal 1 circuit. The sensor also provides a secondary fuel pressure sensor signal on the fuel rail pressure signal 2 circuit. This sensor signal voltage changes based on the pressure in the fuel rail. The ECM will detect a high signal voltage at high rail pressure conditions. The ECM will detect a low signal voltage during low rail pressure conditions.

Component LocationThe high-pressure fuel pump is mounted to the gear housing. The fuel pump actuator is mounted on the fuel pump. The fuel pressure sensor is mounted in the high pressure fuel rail. The fuel pressure relief valve is mounted on the high pressure fuel rail.

Conditions for Running the DiagnosticsThe second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the measured fuel rail pressure was less than the commanded fuel rail pressure by at least 250 bar [3625 psi] for 7 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

High fuel inlet restrictionLow fuel gear pump output pressureAir in the fuelLeaking fuel rail pressure relief valveMalfunctioning high-pressure fuel pumpLeaking fuel injectors and or fuel injector connectors

Possible Cause:1) Fuel Pressure relief Valve failure2) High-Pressure fuel pump head failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 556 PID: PID 101 SPN: 101 FMI: 0 Crankcase Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 555 PID: PID 101 SPN: 101 FMI: 16 Crankcase Pressure- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 553 PID: PID 157 SPN: 157 FMI: 16 Injector Metering Rail 1 Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 516 PID: SID 232 SPN: 3514 FMI: 4 Sensor Supply 6 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 515 PID: SID 232 SPN: 3514 FMI: 3 Sensor Supply 6 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 488 PID: PID 105 SPN: 105 FMI: 16 Intake Manifold 1 Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5655 PID: SPN: 4364 FMI: 31 Aftertreatment 1 SCR Conversion Efficiency- condition Exists

Circuit DescriptionThe engine control module (ECM) monitors the NOx concentration in the engine’s exhaust gases using an aftertreatment intake NOx sensor and an aftertreatment outlet NOx sensor. By comparing these two values, the ECM is able to determine the conversion efficiency of the SCR catalyst and dosing system.

Component LocationThe SCR catalyst is located in the vehicle’s exhaust system, after the diesel particulate filter and decomposition tube.

Conditions for Running the DiagnosticsThis diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the NOx conversion across the SCR catalyst was less than expected.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeIt is necessary to use the “Reset All Faults” command in INSITE™ electronic service tool to clear this fault and extinguish the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL).

Shop TalkTroubleshoot all other active NOx sensor and SCR dosing system related fault codes before this fault.

Possible causes of this fault code include:

Malfunctioning diesel exhaust fluid dosing systemExhaust system leaksMalfunctioning SCR catalystDegraded, diluted, or incorrect diesel exhaust fluidFor unit that has come back into with repeat failures consider the possibility that customer is not using Ultra-low sulfur Diesel fuel

Possible Cause:1) DEF fluid2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5584 PID: SPN: 6773 FMI: 7 Aftertreatment 1 Particulate Sensor Regeneration Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5583 PID: SPN: 6777 FMI: 10 Aftertreatment 1 Particulate Sensor Detection Status- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5582 PID: SPN: 7854 FMI: 2 Aftertreatment 1 Particulate Sensor Module Battery Voltage Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5581 PID: SPN: 7329 FMI: 2 Aftertreatment 1 Particulate Sensor Heater Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5579 PID: SPN: 6778 FMI: 16 Aftertreatment 1 Particulate Sensor Power Supply- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5578 PID: SPN: 6778 FMI: 4 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5689 PID: SPN: 3226 FMI: 11 Aftertreatment 1 Outlet Nox Sensor- Root Cause Not Known

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR outlet temperature has been above 200°C [392° F] for a calibratible period of time while the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the power supply to the outlet NOx sensor was above or below a calibratible threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Short to battery or ground in the OEM harnessOpen NOx sensor power supply circuit in the OEM harnessIncorrect system voltage set-up in INSITE™ electronic service toolInternal malfunction of the outlet NOx sensorThe NOx sensor part number is incorrect.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment outlet NOx sensor failure2)ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5655 PID: SPN: 4364 FMI: 31 Aftertreatment 1 SCR Conversion Efficiency- condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5584 PID: SPN: 6773 FMI: 7 Aftertreatment 1 Particulate Sensor Regeneration Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5583 PID: SPN: 6777 FMI: 10 Aftertreatment 1 Particulate Sensor Detection Status- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5582 PID: SPN: 7854 FMI: 2 Aftertreatment 1 Particulate Sensor Module Battery Voltage Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5581 PID: SPN: 7329 FMI: 2 Aftertreatment 1 Particulate Sensor Heater Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5579 PID: SPN: 6778 FMI: 16 Aftertreatment 1 Particulate Sensor Power Supply- Data Valid But Above Normal Operating range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5715 PID: SPN: 3251 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Differential Pressure- Abnormal Rate of Change

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter differential pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter differential pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter differential pressure sensor signal circuit. This sensor signal voltage changes, based on the differential pressure across the aftertreatment diesel particulate filter.

Component LocationThe aftertreatment diesel particulate filter differential pressure sensor is mounted on the diesel particulate filter. It is a combination sensor that detects both diesel particulate filter differential pressure and outlet pressure. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic consists of two parts:

One part runs when the keyswitch is initially turned ON before the engine is startedThe second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter differential pressure was greater than 1.5 kpa [0.44 in HG] at initial key ON, or is not changing with engine conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

A default value for the aftertreatment diesel particulate filter differential pressure is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault code include:

Stuck in-range aftertreatment diesel particulate filter differential pressure sensor readingHigh resistance in the aftertreatment diesel particulate filter differential pressure sensor signal or return wiresDisconnected or damaged aftertreatment diesel particulate filter differential pressure sensor tubesPlugged aftertreatment differential pressure sensor ports could cause this fault code if pressure is held in the port after the engine is turned off.Frozen, plugged, or restricted aftertreatment DPF differential pressure sensor tubes.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM

For intermittent power supply and data link communication issues with aftertreatment components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing, or intermittent connections.

Possible Cause:1) Aftertreatment DPF differential pressure sensor failure2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5689 PID: SPN: 3226 FMI: 11 Aftertreatment 1 Outlet Nox Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5655 PID: SPN: 4364 FMI: 31 Aftertreatment 1 SCR Conversion Efficiency- condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5584 PID: SPN: 6773 FMI: 7 Aftertreatment 1 Particulate Sensor Regeneration Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5583 PID: SPN: 6777 FMI: 10 Aftertreatment 1 Particulate Sensor Detection Status- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5582 PID: SPN: 7854 FMI: 2 Aftertreatment 1 Particulate Sensor Module Battery Voltage Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5581 PID: SPN: 7329 FMI: 2 Aftertreatment 1 Particulate Sensor Heater Power Supply- Data Erratic, Intermittent, or Incorrect

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5716 PID: SPN: 3610 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Abnormal Rate of Change

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter outlet pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter outlet pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter outlet pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the outlet of the aftertreatment diesel particulate filter.

Component LocationThe aftertreatment diesel particulate filter differential pressure sensor is mounted on the diesel particulate filter. It is a combination sensor that detects both diesel particulate filter differential pressure and outlet pressure. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic consists of two parts:

One part runs when the keyswitch is initially turned ON before the engine is startedThe second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter outlet pressure was greater than 1.5 kpa [0.22 psi] or less than -1.5 kpa [0.22 psi] at initial key ON, or was not changing with engine conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault code include:

Stuck in-range aftertreatment diesel particulate filter outlet pressure sensor readingHigh resistance in the aftertreatment diesel particulate filter outlet pressure sensor signal or return wiresHigher than expected diesel particulate filter outlet pressureExcessive diesel exhaust fluid (DEF) deposits in the aftertreatment decomposition tubePlugged aftertreatment outlet pressure sensor ports could cause this fault code if pressure is held in the port after the engine is turned OFF.Frozen, plugged, or restricted aftertreatment DPF differential pressure sensor tubes.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM

For intermittent power supply and data link communication issues with aftertreatment components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing, or intermittent connections.

Possible Cause:1) Aftertreatment DPF differential pressure sensor failure2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5715 PID: SPN: 3251 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Differential Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5689 PID: SPN: 3226 FMI: 11 Aftertreatment 1 Outlet Nox Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5655 PID: SPN: 4364 FMI: 31 Aftertreatment 1 SCR Conversion Efficiency- condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5584 PID: SPN: 6773 FMI: 7 Aftertreatment 1 Particulate Sensor Regeneration Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5583 PID: SPN: 6777 FMI: 10 Aftertreatment 1 Particulate Sensor Detection Status- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5582 PID: SPN: 7854 FMI: 2 Aftertreatment 1 Particulate Sensor Module Battery Voltage Supply- Data Erratic, Intermittent, or Incorrect

Leer más →