Ir directamente al contenido Ir directamente al menú lateral

Cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4842 PID: SPN: 3364 FMI: 15 Aftertreatment Diesel Exhaust Fluid Quality- Data Valid But Above Normal Operating Range- Least Severe Level

Circuit DescriptionThe aftertreatment diesel exhaust fluid quality sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor is used to measure the concentration of the aftertreatment diesel exhaust fluid in the tank.

Component LocationThe aftertreatment diesel exhaust fluid quality sensor is located in the aftertreatment diesel exhaust fluid tank. It may be a combination sensor with the aftertreatement diesel exhaust fluid tank level and tank temperature sensors. Location of the tank and sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThe diagnostic runs continuously when the following conditions are met:

Keyswitch is in the ON position or when the engine is running.Ambient temperature is above -20°C [-4°F].Vehicle altitude change is less than 305 m [1000 ft] in 1 hour.Conditions for Setting the Fault CodesThe DEF quality sensor has detected that the DEF concentration has risen above a critical threshold.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeStart and idle the engine for 1 minuteThe fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults.

Shop TalkPossible causes of this fault include:

Degraded, diluted, or incorrect diesel exhaust fluidMalfunctioning Aftertreatment DEF Quality Sensor.

Possible Cause:1) DEF fluid2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4839 PID: SPN: 3667 FMI: 31 Engine Air Shutoff- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4769 PID: SPN: 1761 FMI: 10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4768 PID: SPN: 3521 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Property- Root Cause Not known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4751 PID: SPN: 3227 FMI: 21 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4749 PID: SPN: 3227 FMI: 20 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4748 PID: SPN: 3217 FMI: 21 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted Low

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 488 PID: PID 105 SPN: 105 FMI: 16 Intake Manifold 1 Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe intake manifold air temperature sensor monitors intake manifold air temperature and passes information to the electronic control. The intake manifold 1 temperature sensor is a variable resistor sensor and is used to measure the temperature of the air entering the intake manifold of the engine. The electronic control module (ECM) supplies 5 volts to the intake manifold temperature SIGNAL circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the intake manifold temperature.

When the intake air is cold, the sensor or thermistor resistance is high. The ECM signal voltage only pulls down a small amount through the sensor to a ground. Therefore, the ECM senses a high signal voltage or low temperature. When the intake air is warm, the sensor resistance is low. The signal voltage pulls down a large amount. Therefore, the ECM senses a low signal voltage, or a high temperature. This fault code indicates that the intake manifold temperature has exceeded the maximum engine protection limit.

Component LocationThe intake manifold temperature sensor 1 is located in intake manifold 1.

Conditions for Running the DiagnosticsThe first part of the diagnostic runs continuously while the keyswitch is in the ON posistion or the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the intake manifold temperature was greater than a calibrated threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The torque output of the engine will be reduced.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to inactive and the torque derate will be removed immediately after the intake manifold temperature falls below a calibratible limit set in the ECM and the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp and/or MIL immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults.

Shop TalkThe intake manifold 1 temperature sensor measures the temperature of the charge-air as it passes through the intake manifold. Possible causes of this fault code include.

Plugged charge-air cooler finsRestricted airflow through the charge-air coolerUndersized charge-air coolerHigh turbocharger compressor outlet temperature.

Possible Cause:1) Intake Manifold temperature sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 484 PID: PID 129 SPN: 1349 FMI: 4 Injector Metering Rail 2 Pressure Sensor Circuit- Voltage Below Normal, or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 483 PID: PID 129 SPN: 1349 FMI: 3 Injector Metering rail 2 Pressure Sensor Circuit- Voltage Above Normal, or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 452 PID: PID 157 SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 451 PID: SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 442 PID: PID 168 SPN: 168 FMI: 16 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 441 PID: PID 168 SPN: 168 FMI: 18 Battery 1 Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4951 PID: SPN: 6655 FMI: 3 Maintain ECU Power Lamp Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe Engine Control Module (ECM) requires battery power when the keyswitch is ON and for a period of time after the keyswitch is turned OFF. The battery power required lamp is an optional lamp that can be installed to indicate when it is acceptable to remove battery power from the ECM. The lamp will be illuminated when the ECM requires battery power and will extinguish once it is acceptable to remove battery power.

Component LocationThe battery power required lamp is an OEM installed component. Refer to the OEM for component location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the battery power required lamp signal circuit was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A pin-to-pin short circuitAn open circuit in the OEM harnessA malfunctioning battery power required lamp

Possible Cause:1) ECU power lamp failure2) OEM harness3) Engine harness4) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4842 PID: SPN: 3364 FMI: 15 Aftertreatment Diesel Exhaust Fluid Quality- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4839 PID: SPN: 3667 FMI: 31 Engine Air Shutoff- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4769 PID: SPN: 1761 FMI: 10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4768 PID: SPN: 3521 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Property- Root Cause Not known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4751 PID: SPN: 3227 FMI: 21 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4749 PID: SPN: 3227 FMI: 20 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted High

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4952 PID: SPN: 6655 FMI: 4 Maintain ECU Power Lamp Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe Engine Control Module (ECM) requires battery power when the keyswitch is ON and for a period of time after the keyswitch is turned OFF. The battery power required lamp is an optional lamp that can be installed to indicate when it is acceptable to remove battery power from the ECM. The lamp will be illuminated when the ECM requires battery power and will extinguish once it is acceptable to remove battery power.

Component LocationThe battery power required lamp is an OEM installed component. Refer to the OEM for component location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the battery power required lamp signal circuit was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A short circuit to ground in the OEM harnessA pin-to-pin short circuitA malfunctioning battery power required lamp

Possible Cause:1) ECU power lamp failure2) OEM harness3) Engine harness4) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4951 PID: SPN: 6655 FMI: 3 Maintain ECU Power Lamp Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4842 PID: SPN: 3364 FMI: 15 Aftertreatment Diesel Exhaust Fluid Quality- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4839 PID: SPN: 3667 FMI: 31 Engine Air Shutoff- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4769 PID: SPN: 1761 FMI: 10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4768 PID: SPN: 3521 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Property- Root Cause Not known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4751 PID: SPN: 3227 FMI: 21 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted Low

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4956 PID: SPN: 6713 FMI: 13 Variable Geometry Turbocharger Actuator Software- Out of Calibration

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected an application software mismatch with the Turbocharger actuator calibration.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe turbocharger application identification number in the VGT actuator does not match the turbocharger application identification number in the ECM.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4952 PID: SPN: 6655 FMI: 4 Maintain ECU Power Lamp Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4951 PID: SPN: 6655 FMI: 3 Maintain ECU Power Lamp Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4842 PID: SPN: 3364 FMI: 15 Aftertreatment Diesel Exhaust Fluid Quality- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4839 PID: SPN: 3667 FMI: 31 Engine Air Shutoff- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4769 PID: SPN: 1761 FMI: 10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4768 PID: SPN: 3521 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Property- Root Cause Not known

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4957 PID: SPN: 6713 FMI: 31 Variable Geometry Turbocharger Actuator Software- Condition Exists

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe turbocharger actuator calibration revision in the VGT actuator is not compatible with the ECM software.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe turbocharger actuator interface level in the VGT actuator is not compatible with the ECM software.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4956 PID: SPN: 6713 FMI: 13 Variable Geometry Turbocharger Actuator Software- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4952 PID: SPN: 6655 FMI: 4 Maintain ECU Power Lamp Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4951 PID: SPN: 6655 FMI: 3 Maintain ECU Power Lamp Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4842 PID: SPN: 3364 FMI: 15 Aftertreatment Diesel Exhaust Fluid Quality- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4839 PID: SPN: 3667 FMI: 31 Engine Air Shutoff- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4769 PID: SPN: 1761 FMI: 10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Abnormal Rate of Change

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 515 PID: SID 232 SPN: 3514 FMI: 3 Sensor Supply 6 Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe sensor supply 6 circuit of the engine control module (ECM) is a dedicated (+) 5-VDC supply for the fuel rail pressure sensor.

Component LocationSensor Supply 6 originates in the Engine Wiring Harness portion of the ECM. It supplies 5 volts to sensors in the engine wiring harness.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the sensor supply 6 signal voltage was greater than 5.2-VDC for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkHigh voltage on the (+) 5 volt supply line can be caused by a short to battery voltage in the engine harness or connectors, or a malfunctioning ECM.

Possible Cause:1) Engine harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 488 PID: PID 105 SPN: 105 FMI: 16 Intake Manifold 1 Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 484 PID: PID 129 SPN: 1349 FMI: 4 Injector Metering Rail 2 Pressure Sensor Circuit- Voltage Below Normal, or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 483 PID: PID 129 SPN: 1349 FMI: 3 Injector Metering rail 2 Pressure Sensor Circuit- Voltage Above Normal, or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 452 PID: PID 157 SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 451 PID: SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 442 PID: PID 168 SPN: 168 FMI: 16 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 516 PID: SID 232 SPN: 3514 FMI: 4 Sensor Supply 6 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe sensor supply 6 circuit of the engine control module (ECM) is a dedicated (+) 5-VDC supply for the fuel rail pressure sensor.

Component LocationSensor Supply 6 originates in the Engine Wiring Harness portion of the ECM. It supplies 5 volts to sensors in the engine wiring harness.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the sensor supply 6 signal voltage was less than 4.8-VDC for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkLow voltage on the 5 volt supply line can be caused by a short circuit to ground in the supply line, a short circuit between the supply line and a return line, a failed sensor, or a damaged ECM power supply.

Possible Cause:1) Fuel rail pressure sensor failure2) Engine harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 515 PID: SID 232 SPN: 3514 FMI: 3 Sensor Supply 6 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 488 PID: PID 105 SPN: 105 FMI: 16 Intake Manifold 1 Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 484 PID: PID 129 SPN: 1349 FMI: 4 Injector Metering Rail 2 Pressure Sensor Circuit- Voltage Below Normal, or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 483 PID: PID 129 SPN: 1349 FMI: 3 Injector Metering rail 2 Pressure Sensor Circuit- Voltage Above Normal, or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 452 PID: PID 157 SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 451 PID: SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5177 PID: SPN: 6713 FMI: 9 Variable Geometry Turbocharger Actuator Software- Abnormal Update Rate

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) did not receive a valid J1939 data link message from the Variable Geometry Turbocharger (VGT) actuator for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults.

Shop TalkThis fault code indicates that the ECM did not recieve the turbocharger actuator identification message from the VGT actuator.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4957 PID: SPN: 6713 FMI: 31 Variable Geometry Turbocharger Actuator Software- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4956 PID: SPN: 6713 FMI: 13 Variable Geometry Turbocharger Actuator Software- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4952 PID: SPN: 6655 FMI: 4 Maintain ECU Power Lamp Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4951 PID: SPN: 6655 FMI: 3 Maintain ECU Power Lamp Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4842 PID: SPN: 3364 FMI: 15 Aftertreatment Diesel Exhaust Fluid Quality- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4839 PID: SPN: 3667 FMI: 31 Engine Air Shutoff- Condition Exists

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5221 PID: SPN: 3667 FMI: 2 Engine Air Shutoff Status- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe air shutoff valve position switch is located inside the air shutoff valve. During testing, the engine is accelerated and the air shutoff valve closes at a predetermined engine speed. When the air shutoff valve closes, the position switch closes. The ECM monitors the Air Shutoff Valve Position Signal circuit for a change indicating the switch closed.

Component LocationThe air shutoff valve position switch is located inside the air shutoff valve. The air shutoff valve is either an OEM or Cummins® installed component, and is usually located on the air intake connection.

Conditions for Running the DiagnosticsThis diagnostic only runs during an Air Shutoff Valve Test.

Conditions for Setting the Fault CodesThe ECM detects that the air shutoff valve position switch has not closed.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.

Conditions for Clearing the Fault CodeTo clear the fault code and validate the repair, the air shutoff valve must be reset. The air shutoff valve test must be performed and the ECM must see the air shutoff valve position switch close.

Shop TalkPotential causes of this fault code include:

Malfunctioning air shutoff valve solenoid.Malfunctioning air shutoff valve.Malfunctioning air shutoff valve position switchBroken or disconnected air shutoff position switch SIGNAL wire.Broken or disconnected air shutoff position switch RETURN wire.

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5177 PID: SPN: 6713 FMI: 9 Variable Geometry Turbocharger Actuator Software- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4957 PID: SPN: 6713 FMI: 31 Variable Geometry Turbocharger Actuator Software- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4956 PID: SPN: 6713 FMI: 13 Variable Geometry Turbocharger Actuator Software- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4952 PID: SPN: 6655 FMI: 4 Maintain ECU Power Lamp Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4951 PID: SPN: 6655 FMI: 3 Maintain ECU Power Lamp Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4842 PID: SPN: 3364 FMI: 15 Aftertreatment Diesel Exhaust Fluid Quality- Data Valid But Above Normal Operating Range- Least Severe Level

Leer más →