Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4956 PID: SPN: 6713 FMI: 13 Variable Geometry Turbocharger Actuator Software- Out of Calibration

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected an application software mismatch with the Turbocharger actuator calibration.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe turbocharger application identification number in the VGT actuator does not match the turbocharger application identification number in the ECM.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4952 PID: SPN: 6655 FMI: 4 Maintain ECU Power Lamp Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4951 PID: SPN: 6655 FMI: 3 Maintain ECU Power Lamp Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4842 PID: SPN: 3364 FMI: 15 Aftertreatment Diesel Exhaust Fluid Quality- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4839 PID: SPN: 3667 FMI: 31 Engine Air Shutoff- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4769 PID: SPN: 1761 FMI: 10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4768 PID: SPN: 3521 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Property- Root Cause Not known