Skip to content Skip to side menu

Cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3232 PID: SPN: 3216 FMI: 9 Aftertreatment 1 Intake Nox Sensor- Abnormal Update Rate

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThis fault code was triggered when the ECM loses J1939 data link communications with the aftertreatment intake NOx sensor.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be severely reduced.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

The aftertreatment intake NOx sensor is not receiving power from the battery supply circuit in the OEM harness. This can be caused by an open circuit in the power supply wire, malfunctioned NOx sensor fuse, or low voltage supplied by the battery.Open return circuit on the aftertreatment intake NOx sensor circuit between the battery circuit aftertreatment intake NOx sensor.Open or short circuit on the J1939 data link circuit between the engine ECM and aftertreatment intake NOx sensor.Intermittent communications between the aftertreatment intake NOx sensor and the primary engine ECM on the J1939 data linkReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3228 PID: SPN: 3216 FMI: 2 Aftertreatment 1 Intake Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3225 PID: SPN: 3490 FMI: 7 Aftertreatment Purge Air Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3224 PID: SPN: 3490 FMI: 3 Aftertreatment Purge Air Actuator Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3223 PID: SPN: 3490 FMI: 4 Aftertreatment Purge Air Actuator Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3168 PID: SPN: 3936 FMI: 16 Aftertreatment Diesel Particulate Filter System- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3167 PID: SID 382 SPN: 3556 FMI: 18 Aftertreatment Doser- Data Valid But Below Normal Operaing Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3235 PID: SPN: 4363 FMI: 16 Aftertreatment SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running and active regeneration of the aftertreatment diesel particulate filter is not occurring.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the temperature at the SCR catalyst outlet temperature sensor was greater than 650°C [1202°F] for more than 60 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault will go inactive immediately after the SCR outlet temperature drops below the warning limit, and will likely be inactive at the time of diagnosis. For these reasons this troubleshooting tree must be used for both active and inactive fault codes.

Possible causes of this fault code include:

Malfunctioning SCR catalystDegraded, diluted, or incorrect diesel exhaust fluidMalfunctioning in-range SCR outlet temperature sensor.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3232 PID: SPN: 3216 FMI: 9 Aftertreatment 1 Intake Nox Sensor- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3228 PID: SPN: 3216 FMI: 2 Aftertreatment 1 Intake Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3225 PID: SPN: 3490 FMI: 7 Aftertreatment Purge Air Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3224 PID: SPN: 3490 FMI: 3 Aftertreatment Purge Air Actuator Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3223 PID: SPN: 3490 FMI: 4 Aftertreatment Purge Air Actuator Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3168 PID: SPN: 3936 FMI: 16 Aftertreatment Diesel Particulate Filter System- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3236 PID: SPN: 4363 FMI: 0/15 Aftertreatment 1 SCR Outlet Temperature – Data Valid but Above Normal Operating Range – Least Severe Level

Lamp:Amber

Reason:The Selective Catalytic Reduction (SCR) outlet temperature sensor is not changing with engine operating conditions.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment exhaust gas temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment exhaust gas temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment exhaust gas temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, aftertreatment diesel particulate filter outlet temperature, and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment exhaust gas temperature sensor module and can not be replaced individually.

Component Location:The aftertreatment exhaust gas temperature sensor module is located on the aftertreatment catalyst.

Conditions for Running the Diagnostics:The engine must be turned OFF for period of 8 hours before this diagnostic will run. This diagnostic runs when the keyswitch is turned to the ON position after an 8 hour cold soak.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the aftertreatment SCR outlet temperature sensor reading was out of range high.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.2. A default value for the SCR catalyst outlet temperature is used.3. Diesel exhaust fluid injection into the aftertreatment system is disabled.4. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair, the engine must be shut down with the keyswitch in the OFF position for 8 hours. After the 8 hour cold soak turn the keyswitch to the ON position for 30 seconds.2. The fault code status displayed by the diagnostic tool will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. A malfunctioning aftertreatment SCR outlet temperature sensor.2. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.3. For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2556 PID: S70 SPN: 729 FMI: 4/4 Engine Intake Air Heater 1 Circuit – Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2555 PID: S70 SPN: 729 FMI: 3/3 Engine Intake Air Heater 1 Circuit – Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2368 PID: S82 SPN: 1112 FMI: 3/3 Engine Brake Actuator Driver 3 Circuit – Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2365 PID: S82 SPN: 1112 FMI: 4/4 Engine Brake Actuator Driver Output 3 Circuit – Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 383 PID: S70 SPN: 729 FMI: 5/5 Engine Intake Air Heater 1 Circuit – Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6766 PID: SPN: 3521 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Property- Data Valid But Below Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3237 PID: SID 254 SPN: 4340 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid line heaters are used to defrost and/or prevent freezing of the diesel exhaust fluid lines.

Component LocationThe aftertreatment diesel exhaust fluid line heater 1 is located on the supply line between the diesel exhaust fluid dosing unit and the diesel exhaust fluid dosing valve.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and line heating is commanded OFF.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the line heater voltage was above a calibratible value and the line heater current was above a calibratible value.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The line heater will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and then use INSITE™ electronic service tool to perform the Diesel Exhaust Fluid Doser System Heater Test found under ECM Diagnostic Tests.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

Malfunctioning line heaterA short circuit to battery in the OEM harnessReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DEF line heater 1 failure2) Aftertreatment DEF kine heater relay failure3) OEM harness4) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3235 PID: SPN: 4363 FMI: 16 Aftertreatment SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3232 PID: SPN: 3216 FMI: 9 Aftertreatment 1 Intake Nox Sensor- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3228 PID: SPN: 3216 FMI: 2 Aftertreatment 1 Intake Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3225 PID: SPN: 3490 FMI: 7 Aftertreatment Purge Air Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3224 PID: SPN: 3490 FMI: 3 Aftertreatment Purge Air Actuator Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3223 PID: SPN: 3490 FMI: 4 Aftertreatment Purge Air Actuator Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3238 PID: SPN: 4340 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid line heaters are used to defrost and/or prevent freezing of the diesel exhaust fluid lines.

Component LocationThe aftertreatment diesel exhaust fluid line heater 1 is located on the supply line between the diesel exhaust fluid dosing unit and the diesel exhaust fluid dosing valve.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and line heating is commanded ON.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the line heater voltage was below a calibratible value and the line heater current was below a calibratable valure.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The line heater will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and then use INSITE™ electronic service tool to perform the Diesel Exhaust Fluid Doser System Heater Test found under ECM Diagnostic Tests.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A short circuit to ground in the OEM harnessA malfunctioning line heater

Possible Cause:1) Aftertreatment DEF line heater relay failure2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3237 PID: SID 254 SPN: 4340 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3235 PID: SPN: 4363 FMI: 16 Aftertreatment SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3232 PID: SPN: 3216 FMI: 9 Aftertreatment 1 Intake Nox Sensor- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3228 PID: SPN: 3216 FMI: 2 Aftertreatment 1 Intake Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3225 PID: SPN: 3490 FMI: 7 Aftertreatment Purge Air Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3224 PID: SPN: 3490 FMI: 3 Aftertreatment Purge Air Actuator Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3239 PID: SPN: 4342 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid line heaters are used to defrost and/or prevent freezing of the diesel exhaust fluid lines.

Component LocationThe aftertreatment diesel exhaust fluid line heater 2 is located on the return line between the diesel exhaust fluid dosing unit and diesel exhaust fluid tank.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and line heating is commanded OFF.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the line heater voltage was above a calibratible value and the line heater current was above a calibratible value.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The line heater will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and then use INSITE™ electronic service tool to perform the Diesel Exhaust Fluid Doser System Heater Test found under ECM Diagnostic Tests.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

Malfunctioning line heaterA short circuit to battery in the OEM harnessReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DEF line heater 2 failure2) Aftertreatment DEF line heater relay failure3) OEM harness4) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3238 PID: SPN: 4340 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3237 PID: SID 254 SPN: 4340 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3235 PID: SPN: 4363 FMI: 16 Aftertreatment SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3232 PID: SPN: 3216 FMI: 9 Aftertreatment 1 Intake Nox Sensor- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3228 PID: SPN: 3216 FMI: 2 Aftertreatment 1 Intake Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3225 PID: SPN: 3490 FMI: 7 Aftertreatment Purge Air Actuator- Mechanical System Not Responding or Out of Adjustment

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 324 PID: SID 3 SPN: 653 FMI: 5 Injector Solenoid Driver Cylinder 3 Circuit- Current Below Normal or Open Circuit

Circuit DescriptionThe injector solenoid valves control fueling quantity and injection timing. The engine control module (ECM) energizes the solenoid by closing a high-side and a low-side switch. Each injector circuit has a dedicated low-side switch that completes the circuit path to ground inside the ECM.

Component LocationThe engine harness connects the ECM to the pass-through connector(s) that are located in the rocker housing. Internal injector harnesses are located under the valve cover and connect the injectors to the engine harness at the pass-through connector(s).

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a circuit error on an injector(s) circuit. The ECM will disable the injection event for the affected injector(s) circuit if there is excessive current.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The injector will be disabled for the malfunctioning cylinder.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf more than one injector fault code is occurring, and the faults occur for injector circuits in the same bank, a short circuit exists.

If a fault condition is intermittent, and especially if more than one injector fault code is occurring, look for a wire harness that can short to components inside the rocker housing or a short circuit to ground in the injector solenoid. When looking for short circuits in the injector harnesses, pay particular attention to the wire insulation, making sure there are no shorts to a rocker lever. An intermittent short can result if the wiring harness insulation rubs through near a rocker lever. An intermittent short can cause a single injector fault code.

If the fault(s) occur intermittently, the engine can exhibit a misfire even if the injector circuit fault code does not always register. If a single cylinder exhibits misfires, look for an open circuit problem. If several cylinders on the same bank exhibit misfires, look for a short circuit anywhere in the bank of cylinders.

Possible causes of a single injector fault include:

• Open circuit in the engine harness(es) or injector solenoid

• High resistance in a single injector or injector solenoid

• Extremely low resistance in an injector solenoid (injector shorted internally but not to ground)

• Malfunctioning or damaged ECM.

Possible causes of multiple injector fault codes in the same bank of injectors include:

Short circuit in the engine harness(es) – either shorts to ground or to other wires in the engine harnessShort circuit in any of the three injectors in the bank – shorts to groundMalfunctioning or damaged ECM.Same Bank Fault Codes:

Bank 1 – Front Bank: Fault Codes 322, 324, 331Bank 2 – Rear Bank: Fault Codes 323, 325, 332.

Possible Cause:1) Engine harness2) Injector harness3) Injector 1,2,3 failure4) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 323 PID: SID 5 SPN: 655 FMI: 5 Injector Solenoid Driver Cylinder 5 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 322 PID: SID 1 SPN: 651 FMI: 5 Injector Solenoid Driver Cylinder 1 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 295 PID: PID 108 SPN: 108 FMI: 2 Barometric Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 288 PID: PID 372 SPN: 974 FMI: 19 SAE J1939 Multiplexing Remote Accelerator Pedal or Lever Position Sensor System- Received Network Data In Error
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 286 PID: SID 231 SPN: 639 FMI: 13 SAE J1939 Multiplexing Configuration Error- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 285 PID: SID 231 SPN: 639 FMI: 9 SAE J1939 Multiplexing PGN Timeout Error- Abnormal Update Rate

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3241 PID: SPN: 4342 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid line heaters are used to defrost and/or prevent freezing of the diesel exhaust fluid lines.

Component LocationThe aftertreatment diesel exhaust fluid line heater 2 is located on the return line between the diesel exhaust fluid dosing unit and diesel exhaust fluid tank.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and line heating is commanded ON.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the line heater voltage was below a calibratible value and the line heater current was below a calibratable valure.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The line heater will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and then use INSITE™ electronic service tool to perform the Diesel Exhaust Fluid Doser System Heater Test found under ECM Diagnostic Tests.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A short circuit to ground in the OEM harnessA malfunctioning line heater

Possible Cause:1) Aftertreatment DEF line heater relay failure2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3239 PID: SPN: 4342 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3238 PID: SPN: 4340 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3237 PID: SID 254 SPN: 4340 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3235 PID: SPN: 4363 FMI: 16 Aftertreatment SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3232 PID: SPN: 3216 FMI: 9 Aftertreatment 1 Intake Nox Sensor- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3228 PID: SPN: 3216 FMI: 2 Aftertreatment 1 Intake Nox Sensor- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3242 PID: SPN: 3363 FMI: 7 Aftertreatment Diesel Exhaust Fluid Tank Heater- Mechanical System Not Responding or Out of Adjustment

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank heater keeps the diesel exhaust fluid from freezing in the diesel exhaust fluid tank. The tank heater consists of an electrically powered tank heater control valve which controls the flow of engine coolant to a heating coil inside the diesel exhaust fluid tank. The tank heater control valve opens to allow coolant to flow to the heating coil when heating is commanded, and closes when heating is no longer required.

Component LocationThe diesel exhaust fluid tank heater control valve is located near the diesel exhaust fluid tank. Specific location will vary depending on the vehicle OEM. The tank heating coil is internal to the diesel exhaust fluid tank.

Conditions for Running the DiagnosticsThis diagnostic runs a calibrated amount of time after diesel exhaust fluid tank heating is first commanded.

Conditions for Setting the Fault CodesThe aftertreatment diesel exhaust fluid tank heater was commanded on by the engine engine control module (ECM), but no corresponding temperature increase in the aftertreatment diesel exhaust fluid tank temperature was recorded by the tank temperature sensor.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeThe fault code status in INSITE™ electronic service tool will change to INACTIVE immediately after the system is able to adequately heat and the diagnostic runs and passes. If heating can not be completed, use the “Diesel Exhaust Fluid Doser System Heater Test” found under “ECM Diagnostic Test” in INSITE™ electronic service tool to command heating to the tank heater and all line heaters.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Aftertreatment diesel exhaust fluid tank heater control valve stuck closedBlockage or restrictions in the coolant plumbing to the diesel exhaust fluid tank heaterEngine coolant level lowMalfunctioning aftertreatment diesel exhaust fluid tank heater control valveReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Coolant level2) DEF tank heater control valve failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3241 PID: SPN: 4342 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3239 PID: SPN: 4342 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3238 PID: SPN: 4340 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3237 PID: SID 254 SPN: 4340 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3235 PID: SPN: 4363 FMI: 16 Aftertreatment SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3232 PID: SPN: 3216 FMI: 9 Aftertreatment 1 Intake Nox Sensor- Abnormal Update Rate

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3243 PID: SPN: 3060 FMI: 18 Engine Cooling System Monitor- Data valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe coolant temperature sensor is a variable resistor sensor and is used to measure the temperature of the coolant of the engine. The engine control module (ECM) supplies 5 volts to the coolant temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the coolant temperature.

Component LocationThe engine coolant temperature sensor is located on the thermostat housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running if the coolant temperature was less than 52°C [126°F] when the engine was started.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine coolant temperature did not reach 72°C [162°F] in a specified amount of time.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Low coolant level, or air in the cooling systemMalfunctioning coolant temperature sensorMalfunctioning engine coolant thermostat.

Possible Cause:1) Thermostat failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3242 PID: SPN: 3363 FMI: 7 Aftertreatment Diesel Exhaust Fluid Tank Heater- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3241 PID: SPN: 4342 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3239 PID: SPN: 4342 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3238 PID: SPN: 4340 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3237 PID: SID 254 SPN: 4340 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3235 PID: SPN: 4363 FMI: 16 Aftertreatment SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →