Skip to content Skip to side menu

Cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3134 PID: SPN: 3610 FMI: 4 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter outlet pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter outlet pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter outlet pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the outlet of the aftertreatment diesel particulate filter.

Component LocationThe aftertreatment diesel particulate filter differential pressure sensor is mounted on the diesel particulate filter. It is a combination sensor that detects both diesel particulate filter differential pressure and outlet pressure. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter outlet pressure signal voltage was less than 0.25-VDC for more than 2 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

Signal circuit open or shorted to ground in the engine harness or sensorSupply line open or shorted to ground.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3133 PID: SPN: 3610 FMI: 3 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2976 PID: SPN: 3361 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2973 PID: PID 102 SPN: 102 FMI: 2 Intake Manifold 1 Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2964 PID: PID 105 SPN: 105 FMI: 15 Intake Manifold 1 Temperature- Data valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2963 PID: PID 110 SPN: 110 FMI: 15 Engine Coolant Temperature- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2962 PID: PID 412 SPN: 412 FMI: 16 Exhaust Gas Recirculation Temperature- Data valid But Above Normal Operational Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter outlet pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter outlet pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter outlet pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the outlet of the aftertreatment diesel particulate filter.

Component LocationThe aftertreatment diesel particulate filter differential pressure sensor is mounted on the diesel particulate filter. It is a combination sensor that detects both diesel particulate filter differential pressure and outlet pressure. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic consists of two parts:

One part runs when the keyswitch is initially turned ON before the engine is startedThe second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter outlet pressure was greater than 1.5 kpa [0.22 psi] or less than -1.5 kpa [0.22 psi] at initial key ON, or was not changing with engine conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.Turn the key switch OFF and allow the ECM to completely powerdown.To validate the repair, perform a key cycle and leave the key in the ON position for 2 minutes. Then start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Stuck in-range aftertreatment diesel particulate filter outlet pressure sensor readingHigh resistance in the aftertreatment diesel particulate filter outlet pressure sensor signal or return wiresHigher than expected diesel particulate filter outlet pressureExcessive diesel exhaust fluid (DEF) deposits in the aftertreatment decomposition tubePlugged aftertreatment outlet pressure sensor ports could cause this fault code if pressure is held in the port after the engine is turned OFF.Frozen, plugged, or restricted aftertreatment DPF differential pressure sensor tubes.Note: It is possible to set this fault in a shop environment by performing a key cycle with the tailpipe connected to an exhaust ventilation system.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Aftertreatment DPF differential pressure sensor failure2) OEM harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3134 PID: SPN: 3610 FMI: 4 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3133 PID: SPN: 3610 FMI: 3 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2976 PID: SPN: 3361 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2973 PID: PID 102 SPN: 102 FMI: 2 Intake Manifold 1 Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2964 PID: PID 105 SPN: 105 FMI: 15 Intake Manifold 1 Temperature- Data valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2963 PID: PID 110 SPN: 110 FMI: 15 Engine Coolant Temperature- Data Valid But Above Normal Operational Range- Least Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the EGR orifice pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The EGR orifice pressure sensor provides a signal to the ECM on the EGR orifice pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the EGR orifice pressure sensor.

Component LocationThe EGR orifice pressure sensor is mounted on the EGR mass measurement assembly near the EGR differential pressure sensor.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the EGR orifice pressure sensor signal voltage was greater than 4.75-volts for 5 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

Open return circuit in the harness, connectors, or sensorSignal circuit shorted to sensor supply or battery voltage.

Possible Cause:1) ECM failure2) Engine harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3134 PID: SPN: 3610 FMI: 4 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3133 PID: SPN: 3610 FMI: 3 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2976 PID: SPN: 3361 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2973 PID: PID 102 SPN: 102 FMI: 2 Intake Manifold 1 Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2964 PID: PID 105 SPN: 105 FMI: 15 Intake Manifold 1 Temperature- Data valid But Above Normal Operational Range- Least Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the EGR orifice pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The EGR orifice pressure sensor provides a signal to the ECM on the EGR orifice pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the EGR orifice pressure sensor.

Component LocationThe EGR orifice pressure sensor is mounted on the EGR mass measurement assembly near the EGR differential pressure sensor.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the EGR orifice pressure sensor signal voltage was less than 0.25 volts for 5 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

Signal circuit open or shorted to ground in the engine harness or sensorSupply line open or shorted to ground.

Possible Cause:1) ECM failure2) Engine harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3134 PID: SPN: 3610 FMI: 4 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3133 PID: SPN: 3610 FMI: 3 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2976 PID: SPN: 3361 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2973 PID: PID 102 SPN: 102 FMI: 2 Intake Manifold 1 Pressure- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the EGR orifice pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The EGR orifice pressure sensor provides a signal to the ECM on the EGR orifice pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the EGR orifice pressure sensor.

Component LocationThe EGR orifice pressure sensor is mounted on the EGR mass measurement assembly near the EGR differential pressure sensor.

Conditions for Running the DiagnosticsThis is a two part diagnostic.

One part runs immediately after the keyswitch is turned OFF, and the engine coolant temperature is above 70°C or 158°F.

The second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the EGR orifice pressure sensor was not changing with engine conditions or was incorrect at key OFF.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A damaged EGR orifice pressure sensorHigh resistance in the wiring harness on the signal or return wirePlugged or restricted EGR differential pressure sensor flow ports.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3134 PID: SPN: 3610 FMI: 4 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3133 PID: SPN: 3610 FMI: 3 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2976 PID: SPN: 3361 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Temperature- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intake temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe SCR intake temperature sensor is located in the aftertreatment system. It is located between the diesel particulate filter and the SCR catalyst in the exhaust system.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the SCR intake temperature sensor signal voltage was greater than 4.4-VDC for more than 2 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Engine torque will be severely reduced.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after four consecutive trips where the diagnostic runs and passes.

The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe SCR intake temperature sensor shares return wires in the engine harness with other sensors. An open return can cause multiple fault codes to be active.

Possible causes of this fault code include:

Open return circuit in the harness, connectors, or sensorOpen signal circuit or shorted to a voltage sourceMalfunctioning aftertreatment SCR catalyst temperature sensor interface module.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment SCR temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3134 PID: SPN: 3610 FMI: 4 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3133 PID: SPN: 3610 FMI: 3 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe selective catalytic reduction (SCR) intake temperature sensor is used by the engine control module (ECM) to monitor the engine exhaust temperature entering the SCR catalyst. The ECM monitors the voltage on the signal pin and converts this to a temperature value.

Component LocationThe SCR intake temperature sensor is located in the aftertreatment system. It is located between the diesel particulate filter and the SCR catalyst in the exhaust system.

Conditions for Running the DiagnosticsThis diagnostic runs when the exhaust gas temperature sensors are compared to other engine temperatures during engine operation. The engine coolant temperature must be above 60°C [140°F] before the diagnostic will run.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment SCR intermediate temperature sensor signal was irrational for more than 5 minutes.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

A default value for the SCR catalyst intake temperature is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Stuck in-range SCR intake temperature sensorHigh resistance in the SCR intake temperature sensor signal or return linesMalfunctioning aftertreatment SCR catalyst temperature sensor interface module.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment SCR temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3134 PID: SPN: 3610 FMI: 4 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment SCR temperature sensor module reported the aftertreatment SCR outlet temperature signal was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR outlet temperature sensor

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment selective catalyst reduction temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3135 PID: SPN: 3610 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3147 PID: SPN: 4363 FMI: 4 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment SCR temperature sensor module reported the aftertreatment SCR outlet temperature signal was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR outlet temperature sensor

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment selective catalytic reduction temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3148 PID: SPN: 4363 FMI: 2 Aftertreatment 1 SCR Outlet Temperature Sensor- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the exhaust gas temperature sensors are compared to other engine temperatures during engine operation. The engine coolant temperature must be above 60°C [140°F] before the diagnostic will run.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment SCR outlet temperature sensor signal was irrational for more than 5 minutes.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

A default value for the SCR catalyst outlet temperature is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR outlet temperature sensor

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment selective catalytic reduction temperature sensor module2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3147 PID: SPN: 4363 FMI: 4 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3146 PID: SPN: 4363 FMI: 3 Aftertreatment 1 SCR Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3144 PID: SPN: 4360 FMI: 2 Aftertreatment 1 SCR Intake Temperature Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3142 PID: SPN: 4360 FMI: 3 Aftertreatment 1 SCR Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to high Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3138 PID: SPN: 5019 FMI: 2 Engine Exhaust Gas Recirculation Outlet Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source

Read more →