Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3311 PID: SPN: 3242 FMI: 0 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operational Range- Most Severe Level

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel particulate filter intake temperature sensor is located in the aftertreatment system. It is located at the outlet of the diesel oxidation catalyst and before the diesel particulate filter. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running and active regeneration of the aftertreatment diesel particulate filter is occurring.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter intake temperature reading was greater than 800°C [1472°F] for more than 20 seconds, or the temperature differential across the diesel oxidation catalyst was greater than 500°C [932°F] for more than 120 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.The engine will be shut down if the Engine Protection Shutdown feature is enabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault will go inactive immediately after the aftertreatment temperatures drop below the warning limit, and will likely be inactive when the vehicle is in the shop. For these reasons this troubleshooting tree must be used for both active and inactive fault codes.

Possible causes of this fault code include:

A malfunctioning fuel injector causing unburned fuel to enter the exhaust systemExcessive engine oil being introduced into the exhaust system from the engine.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3261 PID: SID 254 SPN: 4342 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3258 PID: SPN: 4340 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3256 PID: SPN: 3246 FMI: 15 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3255 PID: SPN: 3246 FMI: 16 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3254 PID: SPN: 3242 FMI: 15 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3253 PID: SPN: 3242 FMI: 16 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3312 PID: SPN: 3246 FMI: 0 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operational Range- Most Severe Level

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel particulate filter outlet temperature sensor is located in the aftertreatment system. It is located at the outlet of the aftertreatment diesel particulate filter. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter outlet temperature reading was greater than 800°C [1472°F] for 20 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.The engine will be shut down if the Engine Protection Shutdown feature is enabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault will go inactive after the aftertreatment temperatures drop below the warning limit and a key cycle has occurred, and will likely be inactive when the vehicle is in the shop. For these reasons this troubleshooting tree must be used for both active and inactive fault codes.

Possible causes of this fault code include:

A malfunctioning fuel injector causing unburned fuel to enter the exhaust systemExcessive engine oil being introduced into the exhaust system from the engine.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3311 PID: SPN: 3242 FMI: 0 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3261 PID: SID 254 SPN: 4342 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3258 PID: SPN: 4340 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3256 PID: SPN: 3246 FMI: 15 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3255 PID: SPN: 3246 FMI: 16 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3254 PID: SPN: 3242 FMI: 15 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operating Range- Least Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3313 PID: SPN: 4765 FMI: 4 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel oxidation catalyst intake temperature sensor is located in the aftertreatment system. It is located at the intake of the aftertreatment catalyst. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment diesel particulate filter temperature sensor module reported the aftertreatment diesel oxidation catalyst intake temperature signal was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the aftertreatment diesel oxidation catalyst intake temperature sensor reading is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

A malfunctioning aftertreatment diesel oxidation catalyst intake temperature sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DPF temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3312 PID: SPN: 3246 FMI: 0 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3311 PID: SPN: 3242 FMI: 0 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3261 PID: SID 254 SPN: 4342 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3258 PID: SPN: 4340 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3256 PID: SPN: 3246 FMI: 15 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3255 PID: SPN: 3246 FMI: 16 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3314 PID: SPN: 4765 FMI: 3 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel oxidation catalyst intake temperature sensor is located in the aftertreatment system. It is located at the intake of the aftertreatment catalyst. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment diesel particulate filter temperature sensor module reported the aftertreatment diesel oxidation catalyst intake temperature signal was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the aftertreatment diesel oxidation catalyst intake temperature sensor reading is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

A malfunctioning aftertreatment diesel oxidation catalyst intake temperature sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DPF temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3313 PID: SPN: 4765 FMI: 4 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3312 PID: SPN: 3246 FMI: 0 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3311 PID: SPN: 3242 FMI: 0 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3261 PID: SID 254 SPN: 4342 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3258 PID: SPN: 4340 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3256 PID: SPN: 3246 FMI: 15 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operating Range- Least Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3315 PID: SPN: 4765 FMI: 2 Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel oxidation catalyst intake temperature sensor is located in the aftertreatment system. It is located at the intake of the aftertreatment catalyst. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the difference between the aftertreatment diesel oxidation catalyst intake temperature sensor data and diesel particulate filter intake temperature sensor data did not match the expected value for the present engine operating conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

A default value for the aftertreatment diesel oxidation catalyst intake temperature sensor reading is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel particulate filter intake temperature sensorA malfunctioning aftertreatment diesel oxidation catalyst intake temperature sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DPF temperature sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3314 PID: SPN: 4765 FMI: 3 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3313 PID: SPN: 4765 FMI: 4 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3312 PID: SPN: 3246 FMI: 0 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3311 PID: SPN: 3242 FMI: 0 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3261 PID: SID 254 SPN: 4342 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3258 PID: SPN: 4340 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit- Current Below Normal or Open Circuit

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3316 PID: SPN: 3242 FMI: 4 Aftertreatment Diesel Particulate Filter Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel particulate filter intake temperature sensor is located in the aftertreatment system. It is located at the outlet of the diesel oxidation catalyst and before the diesel particulate filter. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment diesel particulate filter temperature sensor module reported the aftertreatment particulate filter intake temperature signal was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the aftertreatment diesel particulate filter intake temperature reading is used.Active and stationary regeneration of the diesel particulate filter will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

A malfunctioning aftertreatment diesel particulate filter intake temperature sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections

Possible Cause:1) Aftertreatment DPF temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3315 PID: SPN: 4765 FMI: 2 Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3314 PID: SPN: 4765 FMI: 3 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3313 PID: SPN: 4765 FMI: 4 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3312 PID: SPN: 3246 FMI: 0 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3311 PID: SPN: 3242 FMI: 0 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3261 PID: SID 254 SPN: 4342 FMI: 5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit- Current Below Normal or Open Circuit

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3317 PID: SPN: 3242 FMI: 3 Aftertreatment Diesel Particulate Filter Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel particulate filter intake temperature sensor is located in the aftertreatment system. It is located at the outlet of the diesel oxidation catalyst and before the diesel particulate filter. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment diesel particulate filter temperature sensor module reported the aftertreatment diesel particulate filter intake temperature signal was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the aftertreatment diesel particulate filter intake temperature reading is used.Active and stationary regeneration of the diesel particulate filter will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

A malfunctioning aftertreatment diesel particulate filter intake temperature sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DPF temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3316 PID: SPN: 3242 FMI: 4 Aftertreatment Diesel Particulate Filter Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3315 PID: SPN: 4765 FMI: 2 Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3314 PID: SPN: 4765 FMI: 3 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3313 PID: SPN: 4765 FMI: 4 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3312 PID: SPN: 3246 FMI: 0 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3311 PID: SPN: 3242 FMI: 0 Aftertreatment Diesel Particulate Filter Intake Temperature- Data Valid But Above Normal Operational Range- Most Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3318 PID: SPN: 3242 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Intake Temperature- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel particulate filter intake temperature sensor is located in the aftertreatment system. It is located at the outlet of the diesel oxidation catalyst and before the diesel particulate filter. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the difference between the aftertreatment diesel particulate filter intake temperature sensor data and diesel particulate filter outlet temperature sensor data did not match the expected value for the present engine operating conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

A default value for the aftertreatment diesel particulate filter intake temperature reading is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel particulate filter intake temperature sensorA malfunctioning aftertreatment diesel particulate filter outlet temperature sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DPF temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3317 PID: SPN: 3242 FMI: 3 Aftertreatment Diesel Particulate Filter Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3316 PID: SPN: 3242 FMI: 4 Aftertreatment Diesel Particulate Filter Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3315 PID: SPN: 4765 FMI: 2 Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3314 PID: SPN: 4765 FMI: 3 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3313 PID: SPN: 4765 FMI: 4 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3312 PID: SPN: 3246 FMI: 0 Aftertreatment Diesel Particulate Filter Outlet Temperature- Data Valid But Above Normal Operational Range- Most Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3319 PID: SPN: 3246 FMI: 3 Aftertreatment Diesel Particulate Filter Outlet Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel particulate filter outlet temperature sensor is located in the aftertreatment system. It is located at the outlet of the aftertreatment diesel particulate filter. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment diesel particulate filter temperature sensor module reported the aftertreatment diesel particulate filter outlet temperature signal was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the aftertreatment diesel particulate filter outlet temperature sensor reading is used.Active and stationary regeneration of the diesel particulate filter will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault include:

A malfunctioning aftertreatment diesel particulate filter outlet temperature sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DPF temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3318 PID: SPN: 3242 FMI: 2 Aftertreatment 1 Diesel Particulate Filter Intake Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3317 PID: SPN: 3242 FMI: 3 Aftertreatment Diesel Particulate Filter Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3316 PID: SPN: 3242 FMI: 4 Aftertreatment Diesel Particulate Filter Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3315 PID: SPN: 4765 FMI: 2 Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3314 PID: SPN: 4765 FMI: 3 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3313 PID: SPN: 4765 FMI: 4 Aftertreatment Diesel Oxidation Catalyst Intake Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 332 PID: SID 4 SPN: 654 FMI: 5 Injector Solenoid Driver Cylinder 4 Circuit- Current Below Normal or Open Circuit

Circuit DescriptionThe injector solenoid valves control fueling quantity and injection timing. The engine control module (ECM) energizes the solenoid by closing a high-side and a low-side switch. Each injector circuit has a dedicated low-side switch that completes the circuit path to ground inside the ECM.

Component LocationThe engine harness connects the ECM to the pass-through connector(s) that are located in the rocker housing. Internal injector harnesses are located under the valve cover and connect the injectors to the engine harness at the pass-through connector(s).

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a circuit error on an injector(s) circuit. The ECM will disable the injection event for the affected injector(s) circuit if there is excessive current.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The injector will be disabled for the malfunctioning cylinder.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf more than one injector fault code is occurring, and the faults occur for injector circuits in the same bank, a short circuit exists.

If a fault condition is intermittent, and especially if more than one injector fault code is occurring, look for a wire harness that can short to components inside the rocker housing or a short circuit to ground in the injector solenoid. When looking for short circuits in the injector harnesses, pay particular attention to the wire insulation, making sure there are no shorts to a rocker lever. An intermittent short can result if the wiring harness insulation rubs through near a rocker lever. An intermittent short can cause a single injector fault code.

If the fault(s) occur intermittently, the engine can exhibit a misfire even if the injector circuit fault code does not always register. If a single cylinder exhibits misfires, look for an open circuit problem. If several cylinders on the same bank exhibit misfires, look for a short circuit anywhere in the bank of cylinders.

Possible causes of a single injector fault include:

Open circuit in the engine harness(es) or injector solenoidHigh resistance in a single injector or injector solenoidExtremely low resistance in an injector solenoid (injector shorted internally but not to ground)Malfunctioning or damaged ECM.Possible causes of multiple injector fault codes in the same bank of injectors include:

Short circuit in the engine harness(es) – either shorts to ground or to other wires in the engine harnessShort circuit in any of the three injectors in the bank – shorts to groundMalfunctioning or damaged ECM.Same Bank Fault Codes:

Bank 1 – Front Bank: Fault Codes 322, 324, 331Bank 2 – Rear Bank: Fault Codes 323, 325, 332.

Possible Cause:1) Injector harness2) Engine harness3) Injector 4,5,6 failure4) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 331 PID: SID 2 SPN: 652 FMI: 5 Injector Solenoid Driver Cylinder 2 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 325 PID: SID 6 SPN: 656 FMI: 5 Injector Solenoid Driver Cylinder 6 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 324 PID: SID 3 SPN: 653 FMI: 5 Injector Solenoid Driver Cylinder 3 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 323 PID: SID 5 SPN: 655 FMI: 5 Injector Solenoid Driver Cylinder 5 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 322 PID: SID 1 SPN: 651 FMI: 5 Injector Solenoid Driver Cylinder 1 Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 295 PID: PID 108 SPN: 108 FMI: 2 Barometric Pressure- Data Erratic, Intermittent, or Incorrect

Read more →