Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 12 Rail Motor Circuit: Bad Intelligent Device

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 61 indicates a failure with the circuit controlling the Rail Motor and the side-to-side movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Rail Motor circuit, the TECU rail motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Rail Motor is energized.

Conditions to Set Fault Code Active:
FMI 12 – Bad Intelligent Device: Transmission fails to complete a shift and the TECU detects intermittent fluctuations in supply voltage due to poor connections, shorted Rail Motor circuit or a hardware failure of the TECU.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while vehicle is moving.
• Until fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 12
1) Vehicle Power Supply
– Poor power or ground supply to TECU (may be in conjunction with Fault Codes 33 or 34)
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) Vehicle Batteries
– Internal failure
3) Vehicle 30-amp Battery Fuse
– Bent, spread, corroded or loose terminals
– Fuse missing or improperly seated
4) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 10 Output Shaft Speed Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 8 Output Shaft Speed Sensor: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 6 Output Shaft Speed Sensor: Current Above Normal or Grounded Circuit

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 61 indicates a failure with the circuit controlling the Rail Motor and the side-to-side movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Rail Motor circuit, the TECU rail motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Rail Motor is energized.

Conditions to Set Fault Code Active:
FMI 5 – Current Below Normal or Open Circuit: Transmission fails to complete a shift, the measured current draw of the Rail Motor is below expected values and an open circuit or short to ground condition is detected for 0.5 seconds.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while vehicle is moving.
• Until fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 1, 5
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
2) X-Y Shifter Rail Motor
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
– Rail Motor shorted to ground, partial short to ground, or open
– Rail Motor internal failure
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 10 Output Shaft Speed Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 8 Output Shaft Speed Sensor: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 6 Output Shaft Speed Sensor: Current Above Normal or Grounded Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 5 Output Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 2 Output Shaft Speed Sensor: Data Erratic

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 61 indicates a failure with the circuit controlling the Rail Motor and the side-to-side movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Rail Motor circuit, the TECU rail motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 6 can be detected when the X-Y Rail Motor is not energized

Conditions to Set Fault Code Active:
FMI 6 – Current Above Normal or Shorted Circuit: TECU detects a short to power on the Rail Motor circuit for 0.5 seconds at power up or prior to a shift.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while vehicle is moving.
• Until fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 6: An electrical short or open circuit is not detected for 0.5 seconds.

Possible Causes:
FMI 6
1) Transmission Harness
– Wiring shorted to power
2) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 10 Output Shaft Speed Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 8 Output Shaft Speed Sensor: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 6 Output Shaft Speed Sensor: Current Above Normal or Grounded Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 5 Output Shaft Speed Sensor: Current Below Normal or Open Circuit

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 1 Gear Motor Circuit: Data Valid but Below Normal

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 63 indicates a failure of the circuit controlling the Gear Motor and the fore-and-aft movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Gear Motor circuit, the TECU gear motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Gear Motor is energized.

Conditions to Set Fault Code Active:
FMI 1 – Data Valid but Below Normal: Transmission fails to complete a shift and the measured current draw of the Gear Motor is below expected values, but no short to ground or open circuit condition is detected.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while the vehicle is moving.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 1, 5
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
2) X-Y Shifter Gear Motor
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
– Gear Motor shorted to ground, partial short to ground, or open
– Gear Motor internal failure
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 12 Gear Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 6 Gear Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 5 Gear Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 1 Gear Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 12 Rail Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 12 Gear Motor Circuit: Bad Intelligent Device

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 63 indicates a failure of the circuit controlling the Gear Motor and the fore-and-aft movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Gear Motor circuit, the TECU gear motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Gear Motor is energized.

Conditions to Set Fault Code Active:
FMI 12 – Bad Intelligent Device: Transmission fails to complete a shift and the TECU detects intermittent fluctuations in supply voltage due to poor connections, shorted Gear Motor circuit or a hardware failure of the TECU

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while the vehicle is moving.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 12
1) Vehicle Power Supply
– Poor power or ground supply to TECU (may be in conjunction with Fault Codes 33 or 34)
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) Vehicle Batteries
– Internal failure
3) Vehicle 30-amp Battery Fuse
– Bent, spread, corroded or loose terminals
– Fuse missing or improperly seated
4) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 6 Gear Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 5 Gear Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 1 Gear Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 12 Gear Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 6 Gear Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 5 Gear Motor Circuit: Current Below Normal or Open Circuit

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 5 Gear Motor Circuit: Current Below Normal or Open Circuit

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 63 indicates a failure of the circuit controlling the Gear Motor and the fore-and-aft movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Gear Motor circuit, the TECU gear motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Gear Motor is energized.

Conditions to Set Fault Code Active:
FMI 5 – Current Below Normal or Open Circuit: Transmission fails to complete a shift, the measured current draw of the Gear Motor is below expected values and an open circuit or short to ground condition is detected for 0.5 seconds.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while the vehicle is moving.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 1, 5
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
2) X-Y Shifter Gear Motor
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
– Gear Motor shorted to ground, partial short to ground, or open
– Gear Motor internal failure
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 1 Gear Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 12 Gear Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 6 Gear Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 5 Gear Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 1 Gear Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 12 Rail Motor Circuit: Bad Intelligent Device

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 6 Gear Motor Circuit: Current Above Normal or Shorted Circuit

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 63 indicates a failure of the circuit controlling the Gear Motor and the fore-and-aft movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Gear Motor circuit, the TECU gear motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 6 can be detected when the X-Y Gear Motor is not energized

Conditions to Set Fault Code Active:
FMI 6 – Current Above Normal or Shorted Circuit: TECU detects a short to power on the Gear Motor circuit for 0.5 seconds at power up or prior to a shift.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while the vehicle is moving.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 6: An electrical short or open circuit is not detected for 0.5 seconds

Possible Causes:
FMI 6
1) Transmission Harness
– Wiring shorted to power
2) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 5 Gear Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SPN: 773 FMI: 1 Gear Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 12 Gear Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 6 Gear Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 5 Gear Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 1 Gear Motor Circuit: Data Valid but Below Normal

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 1 Gear Motor Circuit: Data Valid but Below Normal

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 63 indicates a failure of the circuit controlling the Gear Motor and the fore-and-aft movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Gear Motor circuit, the TECU gear motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Gear Motor is energized.

Conditions to Set Fault Code Active:
FMI 1 – Data Valid but Below Normal: Transmission fails to complete a shift and the measured current draw of the Gear Motor is below expected values, but no short to ground or open circuit condition is detected.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while the vehicle is moving.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 1, 5
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
2) X-Y Shifter Gear Motor
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
– Gear Motor shorted to ground, partial short to ground, or open
– Gear Motor internal failure
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 12 Rail Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 12 Rail Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 12 Gear Motor Circuit: Bad Intelligent Device

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 63 indicates a failure of the circuit controlling the Gear Motor and the fore-and-aft movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Gear Motor circuit, the TECU gear motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Gear Motor is energized.

Conditions to Set Fault Code Active:
FMI 12 – Bad Intelligent Device: Transmission fails to complete a shift and the TECU detects intermittent fluctuations in supply voltage due to poor connections, shorted Gear Motor circuit or a hardware failure of the TECU

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while the vehicle is moving.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 12
1) Vehicle Power Supply
– Poor power or ground supply to TECU (may be in conjunction with Fault Codes 33 or 34)
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) Vehicle Batteries
– Internal failure
3) Vehicle 30-amp Battery Fuse
– Bent, spread, corroded or loose terminals
– Fuse missing or improperly seated
4) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 6 Gear Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 5 Gear Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 1 Gear Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 12 Rail Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 5 Gear Motor Circuit: Current Below Normal or Open Circuit

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 63 indicates a failure of the circuit controlling the Gear Motor and the fore-and-aft movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Gear Motor circuit, the TECU gear motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Gear Motor is energized.

Conditions to Set Fault Code Active:
FMI 5 – Current Below Normal or Open Circuit: Transmission fails to complete a shift, the measured current draw of the Gear Motor is below expected values and an open circuit or short to ground condition is detected for 0.5 seconds.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while the vehicle is moving.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 1, 5
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
2) X-Y Shifter Gear Motor
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
– Gear Motor shorted to ground, partial short to ground, or open
– Gear Motor internal failure
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 1 Gear Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 12 Rail Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 12 Rail Motor Circuit: Bad Intelligent Device