Ir directamente al contenido Ir directamente al menú lateral

Eaton

Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 10 Output Shaft Speed Sensor: Abnormal Rate of Change

Overview:
The Fuller Advantage transmission is equipped with electronic speed sensors. The Input Shaft, Main Shaft and Output Shaft Speed Sensors are used to calculate gear ratios within the transmission. The Input Shaft Speed Sensor measures the rotational speed of the Input Shaft, taken from the upper countershaft drive gear. The Main Shaft Speed Sensor measures the rotational speed of the transmission gearing exiting the main case, taken from the auxiliary upper countershaft gear.

The Output Shaft Speed Sensor measures the rotational speed and direction of the output shaft, taken from the Tone Wheel. The Transmission Electronic Control Unit (TECU) compares these speeds to calculate the gear ratios of the main case, auxiliary case and overall transmission.

The Output Shaft Speed Sensor transmits a digital signal to the TECU based on the rotational speed of the Output Shaft Tone Wheel. The TECU compares Main Shaft Speed to Output Shaft Speed to confirm the gear ratio of the auxiliary case and compares Input Shaft Speed to Output Shaft Speed to confirm the overall transmission gear ratio. Fault Code 58 indicates an electrical fault within the Output Shaft Speed Sensor circuit or a speed value or rotational direction that is inconsistent with the calculated gear ratios.

Detection:
The TECU compares the values of the three speed sensors to determine sensor validity. The TECU also monitors the Output Shaft Speed Sensor circuit for any shorts to power, shorts to ground, open circuits or incorrect rotational direction of the Output Shaft.

Conditions to Set Fault Code Active:
The system can detect Output Shaft Speed Sensor faults when one of the following conditions is present for 1 second or longer:
FMI 10 – Abnormal Rate of Change: TECU detects an excessive rate change.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If fault occurs in low range, transmission still shifts up and down within low range, but will not complete the shift to high range.
• If fault occurs while in high range, the transmission still shifts up and down within high range. Once low range is reached, the transmission will not complete the shift back to high range.

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid signal from the Output Shaft Speed Sensor and detects no electrical open or short circuits for 2 seconds.

Possible Causes:
FMI 10
1) Output Shaft Speed Sensor
– Internal failure
– Physical damage or failure
2) Transmission Harness
– Bent, spread, loose or corroded terminals
– Wiring shorted to ground, shorted to power or open
3) TECU
– Internal failure
4) Mechanical Transmission
– Auxiliary Case: internal failure
– Tone Wheel loose or broken

Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 8 Output Shaft Speed Sensor: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 6 Output Shaft Speed Sensor: Current Above Normal or Grounded Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 5 Output Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 2 Output Shaft Speed Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 5 Main Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 4 Main Shaft Speed Sensor: Voltage Below Normal or Shorted Low

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 2 Output Shaft Speed Sensor: Data Erratic

Overview:
The Fuller Advantage transmission is equipped with electronic speed sensors. The Input Shaft, Main Shaft and Output Shaft Speed Sensors are used to calculate gear ratios within the transmission. The Input Shaft Speed Sensor measures the rotational speed of the Input Shaft, taken from the upper countershaft drive gear. The Main Shaft Speed Sensor measures the rotational speed of the transmission gearing exiting the main case, taken from the auxiliary upper countershaft gear.

The Output Shaft Speed Sensor measures the rotational speed and direction of the output shaft, taken from the Tone Wheel. The Transmission Electronic Control Unit (TECU) compares these speeds to calculate the gear ratios of the main case, auxiliary case and overall transmission.

The Output Shaft Speed Sensor transmits a digital signal to the TECU based on the rotational speed of the Output Shaft Tone Wheel. The TECU compares Main Shaft Speed to Output Shaft Speed to confirm the gear ratio of the auxiliary case and compares Input Shaft Speed to Output Shaft Speed to confirm the overall transmission gear ratio. Fault Code 58 indicates an electrical fault within the Output Shaft Speed Sensor circuit or a speed value or rotational direction that is inconsistent with the calculated gear ratios.

Detection:
The TECU compares the values of the three speed sensors to determine sensor validity. The TECU also monitors the Output Shaft Speed Sensor circuit for any shorts to power, shorts to ground, open circuits or incorrect rotational direction of the Output Shaft.

Conditions to Set Fault Code Active:
The system can detect Output Shaft Speed Sensor faults when one of the following conditions is present for 1 second or longer:
FMI 2 – Data Erratic: TECU detects data from the Output Shaft Speed Sensor does not match the current gear ratio.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If fault occurs in low range, transmission still shifts up and down within low range, but will not complete the shift to high range.
• If fault occurs while in high range, the transmission still shifts up and down within high range. Once low range is reached, the transmission will not complete the shift back to high range.

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid signal from the Output Shaft Speed Sensor and detects no electrical open or short circuits for 2 seconds.

Possible Causes:
FMI 2
1) Output Shaft Speed Sensor
– Internal failure
– Physical damage
2) Mechanical Transmission
– Internal failure in auxiliary case
– Loose or broken Tone Wheel

Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 5 Main Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 4 Main Shaft Speed Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 3 Main Shaft Speed Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 3 Main Shaft Speed Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 2 Main Shaft Speed Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 57 PID: 160 SPN: FMI: 5 Main Shaft Speed Sensor: Current Below Normal or Open Circuit

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 5 Output Shaft Speed Sensor: Current Below Normal or Open Circuit

Overview:
The Fuller Advantage transmission is equipped with electronic speed sensors. The Input Shaft, Main Shaft and Output Shaft Speed Sensors are used to calculate gear ratios within the transmission. The Input Shaft Speed Sensor measures the rotational speed of the Input Shaft, taken from the upper countershaft drive gear. The Main Shaft Speed Sensor measures the rotational speed of the transmission gearing exiting the main case, taken from the auxiliary upper countershaft gear.

The Output Shaft Speed Sensor measures the rotational speed and direction of the output shaft, taken from the Tone Wheel. The Transmission Electronic Control Unit (TECU) compares these speeds to calculate the gear ratios of the main case, auxiliary case and overall transmission.

The Output Shaft Speed Sensor transmits a digital signal to the TECU based on the rotational speed of the Output Shaft Tone Wheel. The TECU compares Main Shaft Speed to Output Shaft Speed to confirm the gear ratio of the auxiliary case and compares Input Shaft Speed to Output Shaft Speed to confirm the overall transmission gear ratio. Fault Code 58 indicates an electrical fault within the Output Shaft Speed Sensor circuit or a speed value or rotational direction that is inconsistent with the calculated gear ratios.

Detection:
The TECU compares the values of the three speed sensors to determine sensor validity. The TECU also monitors the Output Shaft Speed Sensor circuit for any shorts to power, shorts to ground, open circuits or incorrect rotational direction of the Output Shaft.

Conditions to Set Fault Code Active:
The system can detect Output Shaft Speed Sensor faults when one of the following conditions is present for 1 second or longer:
FMI 5 – Current Below Normal or Open Circuit: TECU detects an open circuit or the Output Shaft Speed Sensor has high resistance

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If fault occurs in low range, transmission still shifts up and down within low range, but will not complete the shift to high range.
• If fault occurs while in high range, the transmission still shifts up and down within high range. Once low range is reached, the transmission will not complete the shift back to high range.

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid signal from the Output Shaft Speed Sensor and detects no electrical open or short circuits for 2 seconds.

Possible Causes:
FMI 5
1) Output Shaft Speed Sensor
– Internal failure
– Physical damage or failure
2) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open

Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 2 Output Shaft Speed Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 5 Main Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 4 Main Shaft Speed Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 3 Main Shaft Speed Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 3 Main Shaft Speed Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 2 Main Shaft Speed Sensor: Data Erratic

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 6 Output Shaft Speed Sensor: Current Above Normal or Grounded Circuit

Overview:
The Fuller Advantage transmission is equipped with electronic speed sensors. The Input Shaft, Main Shaft and Output Shaft Speed Sensors are used to calculate gear ratios within the transmission. The Input Shaft Speed Sensor measures the rotational speed of the Input Shaft, taken from the upper countershaft drive gear. The Main Shaft Speed Sensor measures the rotational speed of the transmission gearing exiting the main case, taken from the auxiliary upper countershaft gear.

The Output Shaft Speed Sensor measures the rotational speed and direction of the output shaft, taken from the Tone Wheel. The Transmission Electronic Control Unit (TECU) compares these speeds to calculate the gear ratios of the main case, auxiliary case and overall transmission.

The Output Shaft Speed Sensor transmits a digital signal to the TECU based on the rotational speed of the Output Shaft Tone Wheel. The TECU compares Main Shaft Speed to Output Shaft Speed to confirm the gear ratio of the auxiliary case and compares Input Shaft Speed to Output Shaft Speed to confirm the overall transmission gear ratio. Fault Code 58 indicates an electrical fault within the Output Shaft Speed Sensor circuit or a speed value or rotational direction that is inconsistent with the calculated gear ratios.

Detection:
The TECU compares the values of the three speed sensors to determine sensor validity. The TECU also monitors the Output Shaft Speed Sensor circuit for any shorts to power, shorts to ground, open circuits or incorrect rotational direction of the Output Shaft.

Conditions to Set Fault Code Active:
The system can detect Output Shaft Speed Sensor faults when one of the following conditions is present for 1 second or longer:
FMI 6 – Current Above Normal or Grounded Circuit: TECU detects a short to power in the circuit

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If fault occurs in low range, transmission still shifts up and down within low range, but will not complete the shift to high range.
• If fault occurs while in high range, the transmission still shifts up and down within high range. Once low range is reached, the transmission will not complete the shift back to high range.

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid signal from the Output Shaft Speed Sensor and detects no electrical open or short circuits for 2 seconds.

Possible Causes:
FMI 6, 8
1) Output Shaft Speed Sensor
– Internal failure
– Physical damage or failure

Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 5 Output Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 2 Output Shaft Speed Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 5 Main Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 4 Main Shaft Speed Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 3 Main Shaft Speed Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 3 Main Shaft Speed Sensor: Voltage Above Normal or Shorted High

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 8 Output Shaft Speed Sensor: Abnormal Frequency

Overview:
The Fuller Advantage transmission is equipped with electronic speed sensors. The Input Shaft, Main Shaft and Output Shaft Speed Sensors are used to calculate gear ratios within the transmission. The Input Shaft Speed Sensor measures the rotational speed of the Input Shaft, taken from the upper countershaft drive gear. The Main Shaft Speed Sensor measures the rotational speed of the transmission gearing exiting the main case, taken from the auxiliary upper countershaft gear.

The Output Shaft Speed Sensor measures the rotational speed and direction of the output shaft, taken from the Tone Wheel. The Transmission Electronic Control Unit (TECU) compares these speeds to calculate the gear ratios of the main case, auxiliary case and overall transmission.

The Output Shaft Speed Sensor transmits a digital signal to the TECU based on the rotational speed of the Output Shaft Tone Wheel. The TECU compares Main Shaft Speed to Output Shaft Speed to confirm the gear ratio of the auxiliary case and compares Input Shaft Speed to Output Shaft Speed to confirm the overall transmission gear ratio. Fault Code 58 indicates an electrical fault within the Output Shaft Speed Sensor circuit or a speed value or rotational direction that is inconsistent with the calculated gear ratios.

Detection:
The TECU compares the values of the three speed sensors to determine sensor validity. The TECU also monitors the Output Shaft Speed Sensor circuit for any shorts to power, shorts to ground, open circuits or incorrect rotational direction of the Output Shaft.

Conditions to Set Fault Code Active:
The system can detect Output Shaft Speed Sensor faults when one of the following conditions is present for 1 second or longer:
FMI 8 – Abnormal Frequency: TECU detects an incorrect rotational direction from the Output Shaft Speed Sensor.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If fault occurs in low range, transmission still shifts up and down within low range, but will not complete the shift to high range.
• If fault occurs while in high range, the transmission still shifts up and down within high range. Once low range is reached, the transmission will not complete the shift back to high range.

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid signal from the Output Shaft Speed Sensor and detects no electrical open or short circuits for 2 seconds.

Possible Causes:
FMI 6, 8
1) Output Shaft Speed Sensor
– Internal failure
– Physical damage or failure

Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 6 Output Shaft Speed Sensor: Current Above Normal or Grounded Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 5 Output Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 2 Output Shaft Speed Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 5 Main Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 4 Main Shaft Speed Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 57 PID: SPN: 160 FMI: 3 Main Shaft Speed Sensor: Voltage Above Normal or Shorted High

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 1 Rail Motor Circuit: Data Valid but Below Normal

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 61 indicates a failure with the circuit controlling the Rail Motor and the side-to-side movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Rail Motor circuit, the TECU rail motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Rail Motor is energized.

Conditions to Set Fault Code Active:
FMI 1 – Data Valid but Below Normal: Transmission fails to complete a shift and the measured current draw of the Rail Motor is below expected values, but no short to ground or open circuit condition is detected.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while vehicle is moving.
• Until fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 1, 5
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
2) X-Y Shifter Rail Motor
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
– Rail Motor shorted to ground, partial short to ground, or open
– Rail Motor internal failure
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 12 Rail Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 10 Output Shaft Speed Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 8 Output Shaft Speed Sensor: Abnormal Frequency

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 12 Rail Motor Circuit: Bad Intelligent Device

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 61 indicates a failure with the circuit controlling the Rail Motor and the side-to-side movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Rail Motor circuit, the TECU rail motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Rail Motor is energized.

Conditions to Set Fault Code Active:
FMI 12 – Bad Intelligent Device: Transmission fails to complete a shift and the TECU detects intermittent fluctuations in supply voltage due to poor connections, shorted Rail Motor circuit or a hardware failure of the TECU.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while vehicle is moving.
• Until fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 12
1) Vehicle Power Supply
– Poor power or ground supply to TECU (may be in conjunction with Fault Codes 33 or 34)
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) Vehicle Batteries
– Internal failure
3) Vehicle 30-amp Battery Fuse
– Bent, spread, corroded or loose terminals
– Fuse missing or improperly seated
4) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 12 Rail Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 61 indicates a failure with the circuit controlling the Rail Motor and the side-to-side movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Rail Motor circuit, the TECU rail motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Rail Motor is energized.

Conditions to Set Fault Code Active:
FMI 5 – Current Below Normal or Open Circuit: Transmission fails to complete a shift, the measured current draw of the Rail Motor is below expected values and an open circuit or short to ground condition is detected for 0.5 seconds.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while vehicle is moving.
• Until fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 1, 5
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
2) X-Y Shifter Rail Motor
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
– Rail Motor shorted to ground, partial short to ground, or open
– Rail Motor internal failure
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 12 Rail Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 10 Output Shaft Speed Sensor: Abnormal Rate of Change

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 61 indicates a failure with the circuit controlling the Rail Motor and the side-to-side movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Rail Motor circuit, the TECU rail motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 6 can be detected when the X-Y Rail Motor is not energized

Conditions to Set Fault Code Active:
FMI 6 – Current Above Normal or Shorted Circuit: TECU detects a short to power on the Rail Motor circuit for 0.5 seconds at power up or prior to a shift.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while vehicle is moving.
• Until fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 6: An electrical short or open circuit is not detected for 0.5 seconds.

Possible Causes:
FMI 6
1) Transmission Harness
– Wiring shorted to power
2) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SPN: 772 FMI: 1 Rail Motor Circuit: Data Valid but Below Normal
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 12 Rail Motor Circuit: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 6 Rail Motor Circuit: Current Above Normal or Shorted Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 5 Rail Motor Circuit: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 1 Rail Motor Circuit: Data Valid but Below Normal

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 61 PID: SID 39 SPN: FMI: 1 Rail Motor Circuit: Data Valid but Below Normal

Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 61 indicates a failure with the circuit controlling the Rail Motor and the side-to-side movement of the X-Y Shift Finger.

Detection:
The system can identify an issue with the X-Y Shifter Rail Motor circuit, the TECU rail motor controller or the power and ground connections to the TECU under the following conditions:
• FMI 1, 5 and 12 can be detected when the X-Y Rail Motor is energized.

Conditions to Set Fault Code Active:
FMI 1 – Data Valid but Below Normal: Transmission fails to complete a shift and the measured current draw of the Rail Motor is below expected values, but no short to ground or open circuit condition is detected.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral.
• Transmission does not shift while vehicle is moving.
• Until fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 1, 5, 12: Set Inactive when the shift is completed.

Possible Causes:
FMI 1, 5
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
2) X-Y Shifter Rail Motor
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground or open
– Rail Motor shorted to ground, partial short to ground, or open
– Rail Motor internal failure
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 10 Output Shaft Speed Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 8 Output Shaft Speed Sensor: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 6 Output Shaft Speed Sensor: Current Above Normal or Grounded Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 5 Output Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 58 PID: SPN: 191 FMI: 2 Output Shaft Speed Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 58 PID: 191 SPN: FMI: 10 Output Shaft Speed Sensor: Abnormal Rate of Change

Leer más →