Ir directamente al contenido Ir directamente al menú lateral

Eaton

Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 2 Invalid Shift Lever Voltage: Data Erratic

Overview:
The Fuller Advantage transmission may be equipped with an analog Shift Control Device. The Transmission Electronic Control Unit (TECU) supplies the analog Shift Control Device with a 5-volt reference through OEM wiring. This voltage is reduced by resistive ladder circuitry in the shift device, based on the position the driver selects. The return voltage to the TECU indicates the position of the Shift Lever.

Fault Code 14 indicates the TECU has detected an electrical fault in either the OEM-supplied wiring or Shift Control Device.

Detection:
TECU monitors the voltage from the analog Shift Control Device. Fault Code 14 sets when the reported voltage for a selected mode does not match the actual value for that lever position.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU receives erratic gear position information from the Shift Lever.

Fallback (All FMIs):
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission is limited to down shifts only.
• Transmission may not engage a gear from neutral.
• If a fault occurs with the manual mode up or down buttons, manual mode can not be used. The transmission will shift as normal in auto mode.

Conditions to Set Fault Code Inactive:
All FMIs: Signal voltage enters a valid range for 0.2 seconds.

Possible Causes:
1) Vehicle Harness – Excessive resistance in shifter wiring – Bent, spread, corroded or loose terminals
2) Analog Shift Lever – Internal failure

Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 2 Invalid Shift Lever Voltage: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 13 PID: SPN: 751 FMI: 11 J1939 Shift Control Device: FMI Unknown
Eaton Fuller Advantage (2017) Fault Code: 13 PID: SPN: 751 FMI: 8 J1939 Shift Control Device: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 13 PID: SID 231 SPN: FMI: 11 J1939 Shift Control Device: FMI Unknown

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low

Overview:
The Fuller Advantage transmission may be equipped with an analog Shift Control Device. The Transmission Electronic Control Unit (TECU) supplies the analog Shift Control Device with a 5-volt reference through OEM wiring. This voltage is reduced by resistive ladder circuitry in the shift device, based on the position the driver selects. The return voltage to the TECU indicates the position of the Shift Lever.

Fault Code 14 indicates the TECU has detected an electrical fault in either the OEM-supplied wiring or Shift Control Device.

Detection:
TECU monitors the voltage from the analog Shift Control Device. Fault Code 14 sets when the reported voltage for a selected mode does not match the actual value for that lever position.

Conditions to Set Fault Code Active:
FMI 4 – Voltage Below Normal or Shorted Low: Short to ground is detected, or the voltage value is not defined.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission is limited to down shifts only.
• Transmission may not engage a gear from neutral.
• If a fault occurs with the manual mode up or down buttons, manual mode can not be used. The transmission will shift as normal in auto mode.

Conditions to Set Fault Code Inactive:
All FMIs: Signal voltage enters a valid range for 0.2 seconds.

Possible Causes:
1) Vehicle Harness
– Wires between analog Shift Lever and TECU shorted to ground

Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 2 Invalid Shift Lever Voltage: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 2 Invalid Shift Lever Voltage: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 13 PID: SPN: 751 FMI: 11 J1939 Shift Control Device: FMI Unknown
Eaton Fuller Advantage (2017) Fault Code: 13 PID: SPN: 751 FMI: 8 J1939 Shift Control Device: Abnormal Frequency

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit

Overview:
The Fuller Advantage transmission may be equipped with an analog Shift Control Device. The Transmission Electronic Control Unit (TECU) supplies the analog Shift Control Device with a 5-volt reference through OEM wiring. This voltage is reduced by resistive ladder circuitry in the shift device, based on the position the driver selects. The return voltage to the TECU indicates the position of the Shift Lever.

Fault Code 14 indicates the TECU has detected an electrical fault in either the OEM-supplied wiring or Shift Control Device.

Detection:
TECU monitors the voltage from the analog Shift Control Device. Fault Code 14 sets when the reported voltage for a selected mode does not match the actual value for that lever position.

Conditions to Set Fault Code Active:
FMI 5 – Current Below Normal or Open Circuit: An open circuit is present on the circuit, or the circuit is shorted high.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission is limited to down shifts only.
• Transmission may not engage a gear from neutral.
• If a fault occurs with the manual mode up or down buttons, manual mode can not be used. The transmission will shift as normal in auto mode

Conditions to Set Fault Code Inactive:
All FMIs: Signal voltage enters a valid range for 0.2 seconds.

Possible Causes:
1) Vehicle Harness
– Wires between analog Shift Lever and TECU may be open or shorted to power
2) Analog Shift Lever
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 2 Invalid Shift Lever Voltage: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 2 Invalid Shift Lever Voltage: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 13 PID: SPN: 751 FMI: 11 J1939 Shift Control Device: FMI Unknown

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 15 PID: SPN: 751 FMI: 9 HIL Shift Device Communication: Abnormal Update Rate

Overview:
Vehicles equipped with an Fuller Advantage transmission may also have an Eaton Push Button Shift Control Device (PBSC). The PBSC broadcasts driver shift requests to the Transmission Electronic Control Unit (TECU) through a high speed proprietary data link called the High Integrity Link (HIL). The portion of the HIL that connects the TECU to the PBSC is contained within the 38-Way Vehicle Harness. The Electronic Clutch Actuator (ECA) communicates to the TECU through a portion of the HIL contained in the Transmission Harness. Fault Code 15 indicates a loss of communication between the TECU and PBSC.

Detection:
The TECU monitors communication with the PBSC over the HIL. If the TECU loses communication with the PBSC, Fault Code 15 sets Active.

Conditions to Set Fault Code Active:
FMI 9 – Abnormal Update Rate: TECU loses communication with the PBSC for 5 seconds or longer, but can still communicate with the ECA.

Fallback:
FMI 9
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission may not engage a gear from neutral.
• Transmission is limited to down shifts only.
• Once the transmission re-engages the start gear, the transmission will not shift until the fault becomes Inactive.
• Once the vehicle stops, the transmission will not engage a start gear until the fault becomes Inactive.

Conditions to Set Fault Code Inactive:
FMI 9: The TECU establishes communication with the PBSC for 10 seconds

Possible Causes:
1) High Integrity Link (HIL)
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Missing or additional terminating resistors
2) 38-Way Vehicle Harness Connector
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
3) Vehicle Power and Ground Supply to PBSC
– Poor power or ground supply to PBSC
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
4) PBSC
– Internal failure
5) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 15 PID: SID 18 SPN: FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 14 Invalid Shift Lever Voltage: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 2 Invalid Shift Lever Voltage: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 751 FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 15 PID: SID 18 SPN: FMI: 9 HIL Shift Device Communication: Abnormal Update Rate

Overview:
Vehicles equipped with an Fuller Advantage transmission may also have an Eaton Push Button Shift Control Device (PBSC). The PBSC broadcasts driver shift requests to the Transmission Electronic Control Unit (TECU) through a high speed proprietary data link called the High Integrity Link (HIL). The portion of the HIL that connects the TECU to the PBSC is contained within the 38-Way Vehicle Harness. The Electronic Clutch Actuator (ECA) communicates to the TECU through a portion of the HIL contained in the Transmission Harness. Fault Code 15 indicates a loss of communication between the TECU and PBSC.

Detection:
The TECU monitors communication with the PBSC over the HIL. If the TECU loses communication with the PBSC, Fault Code 15 sets Active.

Conditions to Set Fault Code Active:
FMI 9 – Abnormal Update Rate: TECU loses communication with the PBSC for 5 seconds or longer, but can still communicate with the ECA.

Fallback:
FMI 9
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission may not engage a gear from neutral.
• Transmission is limited to down shifts only.
• Once the transmission re-engages the start gear, the transmission will not shift until the fault becomes Inactive.
• Once the vehicle stops, the transmission will not engage a start gear until the fault becomes Inactive.

Conditions to Set Fault Code Inactive:
FMI 9: The TECU establishes communication with the PBSC for 10 seconds

Possible Causes:
1) High Integrity Link (HIL)
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Missing or additional terminating resistors
2) 38-Way Vehicle Harness Connector
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
3) Vehicle Power and Ground Supply to PBSC
– Poor power or ground supply to PBSC
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
4) PBSC
– Internal failure
5) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 14 Invalid Shift Lever Voltage: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 2 Invalid Shift Lever Voltage: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 751 FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 751 FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 16 PID: SPN: 625 FMI: 2 High Integrity Link: Data Erratic

Overview:
The High Integrity Link (HIL) is a Controller Area Network (CAN) high-speed proprietary data link that communicates data between the Transmission Electronic Control Unit (TECU), Electronic Clutch Actuator (ECA), and if equipped, Eaton Push Button Shift Control (PBSC). The portion of the HIL that connects the TECU to the ECA is contained within the Transmission Harness. The portion of the HIL that connects the TECU to the PBSC is contained within the Vehicle Harness. Fault Code 16 indicates a loss of communication of the HIL.

Detection:
The TECU monitors communication with the Shift Control Device (if equipped) and the ECA over the HIL Link. If the TECU is unable to receive any messages from the other
components on the HIL, Fault Code 16 sets Active.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU does not receive any messages over the HIL for more than 5 seconds.

Fallback:
FMI 2
• Transmission may not engage a gear from neutral.
• Once the transmission down shifts to the start gear, no up shifts occur as long as the fault code is Active.
• If equipped with an Eaton PBSC:
– “F” flashes in gear display.
– Service light flashes (if equipped).
• If equipped with an Eaton Cobra Shift Lever or OEM J1939 Shift Controller:
– “F” does not flash in gear display.
– Service lamp does not flash.

Conditions to Set Fault Code Inactive:
FMI 2: Communication between components is restored for 5 seconds.

Possible Causes:
1) HIL
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Missing terminating resistor
2) Transmission Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Seal failure in 8-Way ECA Connector
– Loss of ignition voltage to ECA before power up
3) ECA
– Failed ECA software download
– Bent, spread, corroded or loose terminals
– Contamination in 3-Way ECA Connector
– Contamination in 8-Way ECA Connector
– Internal failure
4) Vehicle Batteries
– Internal failure
5) Vehicle Power and Ground Supply to ECA
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Seal failure on 3-Way ECA Connector
– Disconnected 3-Way ECA Connector
6) Vehicle Power and Ground Supply to TECU
– Corroded or loose power supply connections to TECU
7) TECU
– Internal failure
8) PBSC
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 16 PID: SID 248 SPN: FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SPN: 751 FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SID 18 SPN: FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 14 Invalid Shift Lever Voltage: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 16 PID: SID 248 SPN: FMI: 2 High Integrity Link: Data Erratic

Overview:
The High Integrity Link (HIL) is a Controller Area Network (CAN) high-speed proprietary data link that communicates data between the Transmission Electronic Control Unit (TECU), Electronic Clutch Actuator (ECA), and if equipped, Eaton Push Button Shift Control (PBSC). The portion of the HIL that connects the TECU to the ECA is contained within the Transmission Harness. The portion of the HIL that connects the TECU to the PBSC is contained within the Vehicle Harness. Fault Code 16 indicates a loss of communication of the HIL.

Detection:
The TECU monitors communication with the Shift Control Device (if equipped) and the ECA over the HIL Link. If the TECU is unable to receive any messages from the other
components on the HIL, Fault Code 16 sets Active.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU does not receive any messages over the HIL for more than 5 seconds.

Fallback:
FMI 2
• Transmission may not engage a gear from neutral.
• Once the transmission down shifts to the start gear, no up shifts occur as long as the fault code is Active.
• If equipped with an Eaton PBSC:
– “F” flashes in gear display.
– Service light flashes (if equipped).
• If equipped with an Eaton Cobra Shift Lever or OEM J1939 Shift Controller:
– “F” does not flash in gear display.
– Service lamp does not flash.

Conditions to Set Fault Code Inactive:
FMI 2: Communication between components is restored for 5 seconds.

Possible Causes:
1) HIL
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Missing terminating resistor
2) Transmission Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Seal failure in 8-Way ECA Connector
– Loss of ignition voltage to ECA before power up
3) ECA
– Failed ECA software download
– Bent, spread, corroded or loose terminals
– Contamination in 3-Way ECA Connector
– Contamination in 8-Way ECA Connector
– Internal failure
4) Vehicle Batteries
– Internal failure
5) Vehicle Power and Ground Supply to ECA
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Seal failure on 3-Way ECA Connector
– Disconnected 3-Way ECA Connector
6) Vehicle Power and Ground Supply to TECU
– Corroded or loose power supply connections to TECU
7) TECU
– Internal failure
8) PBSC
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 15 PID: SPN: 751 FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SID 18 SPN: FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 14 Invalid Shift Lever Voltage: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 2 Invalid Shift Lever Voltage: Data Erratic

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 14 Start Enable Relay: Special Instructions

Overview:
Vehicles with an Fuller Advantage transmission are required to disable engine cranking when the transmission is in a non-neutral gear position. Some vehicles prevent non-neutral engine cranking through the use of a normally open Start Enable Relay actuated by the Transmission Electronic Control Unit (TECU) to interrupt power to the Starter. Other vehicles require the TECU to send a transmission engine crank enable message over the J1939 Data Link before the engine ECU will allow cranking. The Start Enable Relay circuit is supplied and wired by the OEM. For vehicles equipped with a physical Start Enable Relay circuit, the relay will only latch when the following three conditions exist:
• Driver Interface Device is in the neutral position.
• Transmission has confirmed that it is physically in neutral.
• Engine is not running.

Under these conditions the TECU supplies a voltage source and a ground path to the Start Enable Relay coil, latching the relay. The latched relay allows Engine-Starter engagement when the ignition key is turned to the crank position. If these conditions are not met, the TECU removes the voltage source and ground path to the Start Enable Relay, opening the relay and preventing engagement of the Starter. Fault Code 17 indicates that an electrical failure in the Start-Enable Relay circuit was detected. The fault will not set on vehicles that use J1939 messaging to enable engine cranking.

Detection:
This fault can only be detected on transmission systems that are configured for Start Enable Relay. When the ignition key is on, the engine is not running, and the Start Enable Relay coil is not latched, this fault can be detected.

Conditions to Set Fault Code Active:
FMI 14 – Special Instructions: TECU detects an engine start when the Start Enable Relay was not intentionally latched. This is typically an indication that the Start Enable Relay circuit is incorrectly wired or bypassed (jumped).

Fallback:
FMI 14:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If the Start Enable Relay circuit is incorrectly wired or bypassed (jumped), the TECU may not be able to prevent the engine from cranking when the transmission is in a non-neutral position.

Conditions to Set Fault Code Inactive:
FMI 14: Start Enable Relay wiring issue is corrected and Start Enable Relay fault code is unlatched.

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 14 Start Enable Relay: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SPN: 625 FMI: 2 High Integrity Link: Data Erratic

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High

Overview:
Vehicles with an Fuller Advantage transmission are required to disable engine cranking when the transmission is in a non-neutral gear position. Some vehicles prevent non-neutral engine cranking through the use of a normally open Start Enable Relay actuated by the Transmission Electronic Control Unit (TECU) to interrupt power to the Starter. Other vehicles require the TECU to send a transmission engine crank enable message over the J1939 Data Link before the engine ECU will allow cranking. The Start Enable Relay circuit is supplied and wired by the OEM. For vehicles equipped with a physical Start Enable Relay circuit, the relay will only latch when the following three conditions exist:
• Driver Interface Device is in the neutral position.
• Transmission has confirmed that it is physically in neutral.
• Engine is not running.

Under these conditions the TECU supplies a voltage source and a ground path to the Start Enable Relay coil, latching the relay. The latched relay allows Engine-Starter engagement when the ignition key is turned to the crank position. If these conditions are not met, the TECU removes the voltage source and ground path to the Start Enable Relay, opening the relay and preventing engagement of the Starter. Fault Code 17 indicates that an electrical failure in the Start-Enable Relay circuit was detected. The fault will not set on vehicles that use J1939 messaging to enable engine cranking.

Detection:
This fault can only be detected on transmission systems that are configured for Start Enable Relay. When the ignition key is on, the engine is not running, and the Start Enable Relay coil is not latched, this fault can be detected.

Conditions to Set Fault Code Active:
FMI 3 – Voltage Above Normal or Shorted High: TECU detects a short to voltage or an open circuit for at least 1 second.

Fallback:
FMI 3, 4:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine will not crank.

Conditions to Set Fault Code Inactive:
FMI 3, 4: An electrical short or open circuit is not detected for 2 seconds.

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 14 Start Enable Relay: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SPN: 625 FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SID 248 SPN: FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SPN: 751 FMI: 9 HIL Shift Device Communication: Abnormal Update Rate

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low

Overview:
Vehicles with an Fuller Advantage transmission are required to disable engine cranking when the transmission is in a non-neutral gear position. Some vehicles prevent non-neutral engine cranking through the use of a normally open Start Enable Relay actuated by the Transmission Electronic Control Unit (TECU) to interrupt power to the Starter. Other vehicles require the TECU to send a transmission engine crank enable message over the J1939 Data Link before the engine ECU will allow cranking. The Start Enable Relay circuit is supplied and wired by the OEM. For vehicles equipped with a physical Start Enable Relay circuit, the relay will only latch when the following three conditions exist:
• Driver Interface Device is in the neutral position.
• Transmission has confirmed that it is physically in neutral.
• Engine is not running.

Under these conditions the TECU supplies a voltage source and a ground path to the Start Enable Relay coil, latching the relay. The latched relay allows Engine-Starter engagement when the ignition key is turned to the crank position. If these conditions are not met, the TECU removes the voltage source and ground path to the Start Enable Relay, opening the relay and preventing engagement of the Starter. Fault Code 17 indicates that an electrical failure in the Start-Enable Relay circuit was detected. The fault will not set on vehicles that use J1939 messaging to enable engine cranking.

Detection:
This fault can only be detected on transmission systems that are configured for Start Enable Relay. When the ignition key is on, the engine is not running, and the Start Enable Relay coil is not latched, this fault can be detected.

Conditions to Set Fault Code Active:
FMI 4 – Voltage Below Normal or Shorted Low: TECU detects a short to ground for at least 1 second.

Fallback:
FMI 3, 4:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine will not crank.

Conditions to Set Fault Code Inactive:
FMI 3, 4: An electrical short or open circuit is not detected for 2 seconds.

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 14 Start Enable Relay: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SPN: 625 FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SID 248 SPN: FMI: 2 High Integrity Link: Data Erratic

Leer más →