Eaton Gen 1 (AutoShift) Fault Code: 83 PID: SID 18 FMI: 14 Shift Lever Missing

Overview:
This code indicates the Eaton or OEM Shift Lever is not sensing any lever positions.

Detection:
Starting at key-on and throughout operation, the System Manager constantly measures the feedback from the Shift Lever circuit. If the Shift Lever reports no lever positions are sensed, the fault code is set. To allow the System Manager to detect this fault, it is necessary to turn the key on since it constantly monitors for this failure mode.

Fallback
This fault causes a downshift only fallback and shifts to neutral when the vehicle stops.

Required Tools:
1) Basic Hand Tools
2) AutoSelect/AutoShift Troubleshooting Guide

Possible Causes:
1) Lever placed between positions

Eaton Gen 1 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 7 Failed To Sync Initial Engagement
Eaton Gen 1 (AutoShift) Fault Code: 73 PID: SID 58 FMI: 7 Failed To Engage Gear
Eaton Gen 1 (AutoShift) Fault Code: 72 PID: SID 59 FMI: 7 Failed To Select Rail
Eaton Gen 1 (AutoShift) Fault Code: 71 PID: SID 60 FMI: 7 Stuck Engaged
Eaton Gen 1 (AutoShift) Fault Code: 65 PID: SID 251 FMI: 4 Low Motor Voltage
Eaton Gen 1 (AutoShift) Fault Code: 63 PID: SID 40 FMI: 6 Gear Select Motor

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 11 PID: SPN: 629 FMI: 12 No TECU Operation: Bad Intelligent Device

Overview:
The Fuller Advantage transmission is equipped with a Transmission Electronic Control Unit (TECU). The TECU performs a variety of functions including receiving inputs from sensors, sending outputs to control devices, operating X-Y Shifter motors and actuators and making shift decisions. Fault Code 11 indicates an internal failure of the TECU.

Detection:
The TECU performs a self-check during power up, any failure detected sets this fault.

Conditions to Set Fault Code Active:
FMI 12 – Bad Intelligent Device: TECU detects an internal failure.

Fallback:
FMI 12
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not attempt to shift.
• Transmission may not confirm neutral.
• Engine may have to be shut down with transmission still in gear.

Conditions to Set Fault Code Inactive:
FMI 12: Transmission powers up and the failure is no longer detected by the TECU.

Possible Causes:
1) TECU
2) Internal failure

Eaton Fuller Advantage (2017) Fault Code: 11 PID: SID 254 SPN: FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Gen 1 (AutoShift) Fault Code: 83 PID: SID 18 FMI: 14 Shift Lever Missing
Eaton Gen 1 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 7 Failed To Sync Initial Engagement
Eaton Gen 1 (AutoShift) Fault Code: 73 PID: SID 58 FMI: 7 Failed To Engage Gear
Eaton Gen 1 (AutoShift) Fault Code: 72 PID: SID 59 FMI: 7 Failed To Select Rail
Eaton Gen 1 (AutoShift) Fault Code: 71 PID: SID 60 FMI: 7 Stuck Engaged

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 11 PID: SID 254 SPN: FMI: 12 No TECU Operation: Bad Intelligent Device

Overview:
The Fuller Advantage transmission is equipped with a Transmission Electronic Control Unit (TECU). The TECU performs a variety of functions including receiving inputs from sensors, sending outputs to control devices, operating X-Y Shifter motors and actuators and making shift decisions. Fault Code 11 indicates an internal failure of the TECU.

Detection:
The TECU performs a self-check during power up, any failure detected sets this fault.

Conditions to Set Fault Code Active:
FMI 12 – Bad Intelligent Device: TECU detects an internal failure.

Fallback:
FMI 12
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not attempt to shift.
• Transmission may not confirm neutral.
• Engine may have to be shut down with transmission still in gear.

Conditions to Set Fault Code Inactive:
FMI 12: Transmission powers up and the failure is no longer detected by the TECU.

Possible Causes:
1) TECU
2) Internal failure

Eaton Gen 1 (AutoShift) Fault Code: 83 PID: SID 18 FMI: 14 Shift Lever Missing
Eaton Gen 1 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 7 Failed To Sync Initial Engagement
Eaton Gen 1 (AutoShift) Fault Code: 73 PID: SID 58 FMI: 7 Failed To Engage Gear
Eaton Gen 1 (AutoShift) Fault Code: 72 PID: SID 59 FMI: 7 Failed To Select Rail
Eaton Gen 1 (AutoShift) Fault Code: 71 PID: SID 60 FMI: 7 Stuck Engaged
Eaton Gen 1 (AutoShift) Fault Code: 65 PID: SID 251 FMI: 4 Low Motor Voltage

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 12 PID: SPN: 629 FMI: 13 Improper TECU Configuration: Out of Calibration

Overview:
The Fuller Advantage transmission is equipped with a Transmission Electronic Control Unit (TECU). The TECU performs a variety of functions including receiving inputs from sensors, sending outputs to control devices, operating X-Y Shifter motors and actuators and making shift decisions. Fault Code 12 indicates an internal failure of the TECU.

Detection:
The TECU performs a self-check during power up. If the TECU does not detect valid memory, or if there are missing or corrupt transmission configuration files, this fault sets Active.

Conditions to Set Fault Code Active:
FMI 13 – Out of Calibration: TECU is unable to determine the proper transmission configuration.

Fallback:
FMI 13
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear.
• Transmission may not make up shifts or down shifts.
• Engine may have to be shut down with transmission still in gear.

Conditions to Set Fault Code Inactive:
FMI 13: TECU has detected a proper configuration for the transmission.

Possible Causes:
1) TECU
2) Internal failure

Eaton Fuller Advantage (2017) Fault Code: 12 PID: SID 254 SPN: FMI: 13 Improper TECU Configuration: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SPN: 629 FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SID 254 SPN: FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Gen 1 (AutoShift) Fault Code: 83 PID: SID 18 FMI: 14 Shift Lever Missing
Eaton Gen 1 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 7 Failed To Sync Initial Engagement
Eaton Gen 1 (AutoShift) Fault Code: 73 PID: SID 58 FMI: 7 Failed To Engage Gear

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 12 PID: SID 254 SPN: FMI: 13 Improper TECU Configuration: Out of Calibration

Overview:
The Fuller Advantage transmission is equipped with a Transmission Electronic Control Unit (TECU). The TECU performs a variety of functions including receiving inputs from sensors, sending outputs to control devices, operating X-Y Shifter motors and actuators and making shift decisions. Fault Code 12 indicates an internal failure of the TECU.

Detection:
The TECU performs a self-check during power up. If the TECU does not detect valid memory, or if there are missing or corrupt transmission configuration files, this fault sets Active.

Conditions to Set Fault Code Active:
FMI 13 – Out of Calibration: TECU is unable to determine the proper transmission configuration.

Fallback:
FMI 13
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear.
• Transmission may not make up shifts or down shifts.
• Engine may have to be shut down with transmission still in gear.

Conditions to Set Fault Code Inactive:
FMI 13: TECU has detected a proper configuration for the transmission.

Possible Causes:
1) TECU
2) Internal failure

Eaton Fuller Advantage (2017) Fault Code: 11 PID: SPN: 629 FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SID 254 SPN: FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Gen 1 (AutoShift) Fault Code: 83 PID: SID 18 FMI: 14 Shift Lever Missing
Eaton Gen 1 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 7 Failed To Sync Initial Engagement
Eaton Gen 1 (AutoShift) Fault Code: 73 PID: SID 58 FMI: 7 Failed To Engage Gear
Eaton Gen 1 (AutoShift) Fault Code: 72 PID: SID 59 FMI: 7 Failed To Select Rail

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 13 PID: SPN: 751 FMI: 11 J1939 Shift Control Device: FMI Unknown

Overview:
The Fuller Advantage transmission may be equipped with a J1939 Shift Control Device. This version of the Shift Control Device uses the J1939 Data Link to broadcast the driver’s shift request to the Transmission Electronic Control Unit (TECU). The system includes redundant neutral request and neutral confirmation signals hard-wired between the Shift Control Device and TECU. These redundant signals allow the transmission to achieve neutral if the J1939 Data Link fails.

Fault Code 13 indicates that either the TECU lost J1939 Data Link communications with the Shift Control Device or that the neutral request status received over J1939 and the neutral request status received through the hard-wired signal do not match

Detection:
The ignition key is on and the TECU has not detected any low battery system faults.

Conditions to Set Fault Code Active:
FMI 11 – FMI Unknown: TECU has lost communication with the J1939 Shift Control Device but can communicate with other devices on the J1939 Data Link. When no J1939 messages have been received for 5 seconds, the fault code sets Active.

Fallback:
FMI 11
• “F” does not flash in gear display.
• Service light does not flash (if equipped).
• Transmission may not attempt to shift.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid message over the J1939 Data Link

Possible Causes:
1) Data Link
– Bent, spread, or loose terminals
– Wiring shorted to ground, shorted to power or open
2) Vehicle Harness
– Bent, spread or loose terminals
3) Shift Control Device Power Supply
– Loss of supply battery voltage
– Loss of supply ignition voltage
– Loss of supply ground connection
4) Shift Control Device
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 13 PID: SPN: 751 FMI: 8 J1939 Shift Control Device: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 13 PID: SID 231 SPN: FMI: 11 J1939 Shift Control Device: FMI Unknown
Eaton Fuller Advantage (2017) Fault Code: 13 PID: SID 231 SPN: FMI: 8 J1939 Shift Control Device: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 12 PID: SPN: 629 FMI: 13 Improper TECU Configuration: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 12 PID: SID 254 SPN: FMI: 13 Improper TECU Configuration: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SPN: 629 FMI: 12 No TECU Operation: Bad Intelligent Device

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 13 PID: SPN: 751 FMI: 8 J1939 Shift Control Device: Abnormal Frequency

Overview:
The Fuller Advantage transmission may be equipped with a J1939 Shift Control Device. This version of the Shift Control Device uses the J1939 Data Link to broadcast the driver’s shift request to the Transmission Electronic Control Unit (TECU). The system includes redundant neutral request and neutral confirmation signals hard-wired between the Shift Control Device and TECU. These redundant signals allow the transmission to achieve neutral if the J1939 Data Link fails.

Fault Code 13 indicates that either the TECU lost J1939 Data Link communications with the Shift Control Device or that the neutral request status received over J1939 and the neutral request status received through the hard-wired signal do not match.

Detection:
The ignition key is on and the TECU has not detected any low battery system faults.

Conditions to Set Fault Code Active
FMI 8 – Abnormal Frequency: TECU compares the J1939 Data Link message from the Shift Control Device to the hard-wired neutral signal request. When 10 consecutive messages do not match, the fault code sets Active.

Fallback:
FMI 8
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid message over the J1939 Data Link.

Possible Causes:
1) Vehicle Harness
2) Bent, spread or loose terminals
3) Wiring shorted to ground, shorted to power or open
4) Shift Control Device
5) Internal failure

Eaton Fuller Advantage (2017) Fault Code: 13 PID: SID 231 SPN: FMI: 11 J1939 Shift Control Device: FMI Unknown
Eaton Fuller Advantage (2017) Fault Code: 13 PID: SID 231 SPN: FMI: 8 J1939 Shift Control Device: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 12 PID: SPN: 629 FMI: 13 Improper TECU Configuration: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 12 PID: SID 254 SPN: FMI: 13 Improper TECU Configuration: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SPN: 629 FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SID 254 SPN: FMI: 12 No TECU Operation: Bad Intelligent Device

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 13 PID: SID 231 SPN: FMI: 11 J1939 Shift Control Device: FMI Unknown

Overview:
The Fuller Advantage transmission may be equipped with a J1939 Shift Control Device. This version of the Shift Control Device uses the J1939 Data Link to broadcast the driver’s shift request to the Transmission Electronic Control Unit (TECU). The system includes redundant neutral request and neutral confirmation signals hard-wired between the Shift Control Device and TECU. These redundant signals allow the transmission to achieve neutral if the J1939 Data Link fails.

Fault Code 13 indicates that either the TECU lost J1939 Data Link communications with the Shift Control Device or that the neutral request status received over J1939 and the neutral request status received through the hard-wired signal do not match

Detection:
The ignition key is on and the TECU has not detected any low battery system faults.

Conditions to Set Fault Code Active:
FMI 11 – FMI Unknown: TECU has lost communication with the J1939 Shift Control Device but can communicate with other devices on the J1939 Data Link. When no J1939 messages have been received for 5 seconds, the fault code sets Active.

Fallback:
FMI 11
• “F” does not flash in gear display.
• Service light does not flash (if equipped).
• Transmission may not attempt to shift.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid message over the J1939 Data Link

Possible Causes:
1) Data Link
– Bent, spread, or loose terminals
– Wiring shorted to ground, shorted to power or open
2) Vehicle Harness
– Bent, spread or loose terminals
3) Shift Control Device Power Supply
– Loss of supply battery voltage
– Loss of supply ignition voltage
– Loss of supply ground connection
4) Shift Control Device
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 13 PID: SID 231 SPN: FMI: 8 J1939 Shift Control Device: Abnormal Frequency
Eaton Fuller Advantage (2017) Fault Code: 12 PID: SPN: 629 FMI: 13 Improper TECU Configuration: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 12 PID: SID 254 SPN: FMI: 13 Improper TECU Configuration: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SPN: 629 FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SID 254 SPN: FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Gen 1 (AutoShift) Fault Code: 83 PID: SID 18 FMI: 14 Shift Lever Missing

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 13 PID: SID 231 SPN: FMI: 8 J1939 Shift Control Device: Abnormal Frequency

Overview:
The Fuller Advantage transmission may be equipped with a J1939 Shift Control Device. This version of the Shift Control Device uses the J1939 Data Link to broadcast the driver’s shift request to the Transmission Electronic Control Unit (TECU). The system includes redundant neutral request and neutral confirmation signals hard-wired between the Shift Control Device and TECU. These redundant signals allow the transmission to achieve neutral if the J1939 Data Link fails.

Fault Code 13 indicates that either the TECU lost J1939 Data Link communications with the Shift Control Device or that the neutral request status received over J1939 and the neutral request status received through the hard-wired signal do not match.

Detection:
The ignition key is on and the TECU has not detected any low battery system faults.

Conditions to Set Fault Code Active
FMI 8 – Abnormal Frequency: TECU compares the J1939 Data Link message from the Shift Control Device to the hard-wired neutral signal request. When 10 consecutive messages do not match, the fault code sets Active.

Fallback:
FMI 8
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission may not engage a gear from neutral

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid message over the J1939 Data Link.

Possible Causes:
1) Vehicle Harness
2) Bent, spread or loose terminals
3) Wiring shorted to ground, shorted to power or open
4) Shift Control Device
5) Internal failure

Eaton Fuller Advantage (2017) Fault Code: 12 PID: SPN: 629 FMI: 13 Improper TECU Configuration: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 12 PID: SID 254 SPN: FMI: 13 Improper TECU Configuration: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SPN: 629 FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 11 PID: SID 254 SPN: FMI: 12 No TECU Operation: Bad Intelligent Device
Eaton Gen 1 (AutoShift) Fault Code: 83 PID: SID 18 FMI: 14 Shift Lever Missing
Eaton Gen 1 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 7 Failed To Sync Initial Engagement

Leer más →

Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 751 FMI: 2 Invalid Shift Lever Voltage: Data Erratic

Overview:
The Fuller Advantage transmission may be equipped with an analog Shift Control Device. The Transmission Electronic Control Unit (TECU) supplies the analog Shift Control Device with a 5-volt reference through OEM wiring. This voltage is reduced by resistive ladder circuitry in the shift device, based on the position the driver selects. The return voltage to the TECU indicates the position of the Shift Lever.

Fault Code 14 indicates the TECU has detected an electrical fault in either the OEM-supplied wiring or Shift Control Device.

Detection:
TECU monitors the voltage from the analog Shift Control Device. Fault Code 14 sets when the reported voltage for a selected mode does not match the actual value for that lever position.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU receives erratic gear position information from the Shift Lever.

Fallback (All FMIs):
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission is limited to down shifts only.
• Transmission may not engage a gear from neutral.
• If a fault occurs with the manual mode up or down buttons, manual mode can not be used. The transmission will shift as normal in auto mode.

Conditions to Set Fault Code Inactive:
All FMIs: Signal voltage enters a valid range for 0.2 seconds.

Possible Causes:
1) Vehicle Harness – Excessive resistance in shifter wiring – Bent, spread, corroded or loose terminals
2) Analog Shift Lever – Internal failure

Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 14 Invalid Shift Lever Voltage: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 19 SPN: FMI: 2 Invalid Shift Lever Voltage: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SID 18 SPN: FMI: 4 Invalid Shift Lever Voltage: Voltage Below Normal or Shorted Low