DESCRIPTION:5V sensor supply bank 1 circuit failed low.
MONITORED PARAMETER:Aftertreatment Control Module (ACM) 5V internal power supply.
TYPICAL ENABLING CONDITIONS:Always enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Always enabled
TYPICAL DURATION:Two seconds
DASH LAMPS:1. MIL2. CEL
ENGINE REACTION:None
VERIFICATION:Engine Idle: One minute.
PROBABLE CAUSES:Short to power from the MCM pins to a sensor:1. Pin 58, charge air cooler outlet pressure sensor.2. Pin 102, charge air cooler pressure sensor.