Paccar
PACCAR PX-6 CM2150 (2007-09) Fault Code: 585 PID: SID 039 SPN: 677 FMI: 4 Starter Relay Driver Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at starter lockout circuit.
Posted by Diezel Solutions on
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. The ECM monitors the voltage level on this circuit. If it detects a low voltage when the signal is commanded on, it records this fault code. This fault code can be caused by a short circuit to ground in the starter lockout relay, OEM harness, or connectors. Possible repairs: 1)Replace the starter lockout relay.2)Clean, repair, or replace the OEM harness.3)Repair or replace the OEM harness.4)Replace the ECM....
PACCAR PX-6 CM2150 (2007-09) Fault Code: 596 PID: 167 SPN: 167 FMI: 0 Electrical Charging System Voltage – Data Valid But Above Normal Operating Range – Moderately Severe Level. High battery voltage detected by the battery voltage monitor feature.
Posted by Diezel Solutions on
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, calibrate the ECM. This fault code is part of the Alternator Failure Warning feature. The ECM can increase idle speed and deactivate the idle decrement switch if idle speedup is enabled. View the Alternator Failure Warning feature settings with INSITE™ electronic service tool. Disabling the Alternator Failure Warning feature will also disable this fault code. Make sure the ECM battery supply (+) is coming directly from the battery and not...
PACCAR PX-6 CM2150 (2007-09) Fault Code: 597 PID: 167 SPN: 167 FMI: 1 Electrical Charging System Voltage – Data Valid But Below Normal Operating Range – Moderately Severe Level. Low battery voltage detected by the battery voltage monitor feature.
Posted by Diezel Solutions on
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. This fault code is part of the Alternator Failure Warning feature. The ECM can increase idle speed and deactivate the idle decrement switch if Idle Speedup is enabled. View the Alternator Failure Warning feature settings using the INSITE™ electronic service tool. Disabling the Alternator Failure Warning feature will also disable this fault code. Make sure the ECM unswitched battery supply is coming directly from the battery and...
PACCAR PX-6 CM2150 (2007-09) Fault Code: 598 PID: 167 SPN: 167 FMI: 1 Electrical Charging System Voltage – Data Valid But Below Normal Operating Range – Most Severe Level. Very low battery voltage detected by the battery voltage monitor feature.
Posted by Diezel Solutions on
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, calibrate the ECM. Use the corresponding service manual for the engine bening serviced. This fault code is part of the Alternator Failure Warning feature. The ECM can increase idle speed and deactivate the idle decrement switch if Idle Speedup is enabled. View the Alternator Failure Warning feature settings with INSITE™ electronic service tool. Disabling the Alternator Failure Warning feature will also disable this fault code. Make sure the ECM battery...
PACCAR PX-6 CM2150 (2007-09) Fault Code: 599 PID: SID 025 SPN: 640 FMI: 14 Auxiliary Commanded Dual Output Shutdown – Special Instructions. The engine protection limit has been exceeded for the dual outputs calibrated limits.
Posted by Diezel Solutions on
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. This fault code is activated when one of the OEM defined inputs has exceeded a calibratible limit. The triggers for shutdown are OEM dependent. Possible repairs: 1)Replace the OEM harness.2)If necessary, recalibrate the ECM. PACCAR PX-6 CM2150 (2007-09) Fault Code: 598 PID: 167 SPN: 167 FMI: 1 Electrical Charging System Voltage – Data Valid But Below Normal Operating Range – Most Severe Level. Very low battery voltage detected by the battery voltage...