Skip to content Skip to side menu

Eaton

Eaton Fuller Advantage (2017) Fault Code: 45 PID: SPN: 787 FMI: 7 Inertia Brake Performance: Mechanical System Not Responding

Overview:
The Fuller Advantage transmission is equipped with a Low Capacity Inertia Brake (LCIB) to slow Input Shaft speed for more efficient gear engagement. As the Electronic Clutch Actuator (ECA) pulls the Heavy-Duty ECA Clutch Release Bearing back against the LCIB, the friction plates contained within the LCIB make contact with the outer plates and slow the Input Shaft down to allow smoother gear engagement. Fault Code 45 indicates the LCIB failed to reduce Input Shaft speed.

Detection:
The Transmission Electronic Control Unit (TECU) commands the ECA to open the clutch and contact the LCIB. If the TECU does not see a significant enough drop in Input Shaft speed, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 7 – Mechanical System Not Responding: During LCIB engagement Input Shaft speed deceleration is less than 1000 RPM/sec for 0.15 seconds with significant current applied to the ECA and the transmission in a non-neutral mode.

Fallback:
FMI 7
• No fallback mode associated with this fault; however, slow-to-shift or difficulty engaging start gear complaints may be presented.

Conditions to Set Fault Code Inactive:
FMI 7: Input Shaft Speed deceleration is above 1000 RPM/sec.

Possible Causes:
FMI 7
1) LCIB
– Oil leak contamination
– Excessive release bearing greasing
– Internal wear or damage
2) ECA
– Internal failure
3) ECA Clutch
– Excessive clutch drag
4) Engine
– Failed pilot bearing

Eaton Fuller Advantage (2017) Fault Code: 45 PID: SID 54 SPN: FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 768 FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 768 FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low

Read more →

Eaton Fuller Advantage (2017) Fault Code: 45 PID: SID 54 SPN: FMI: 7 Inertia Brake Performance: Mechanical System Not Responding

Overview:
The Fuller Advantage transmission is equipped with a Low Capacity Inertia Brake (LCIB) to slow Input Shaft speed for more efficient gear engagement. As the Electronic Clutch Actuator (ECA) pulls the Heavy-Duty ECA Clutch Release Bearing back against the LCIB, the friction plates contained within the LCIB make contact with the outer plates and slow the Input Shaft down to allow smoother gear engagement. Fault Code 45 indicates the LCIB failed to reduce Input Shaft speed.

Detection:
The Transmission Electronic Control Unit (TECU) commands the ECA to open the clutch and contact the LCIB. If the TECU does not see a significant enough drop in Input Shaft speed, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 7 – Mechanical System Not Responding: During LCIB engagement Input Shaft speed deceleration is less than 1000 RPM/sec for 0.15 seconds with significant current applied to the ECA and the transmission in a non-neutral mode.

Fallback:
FMI 7
• No fallback mode associated with this fault; however, slow-to-shift or difficulty engaging start gear complaints may be presented.

Conditions to Set Fault Code Inactive:
FMI 7: Input Shaft Speed deceleration is above 1000 RPM/sec.

Possible Causes:
FMI 7
1) LCIB
– Oil leak contamination
– Excessive release bearing greasing
– Internal wear or damage
2) ECA
– Internal failure
3) ECA Clutch
– Excessive clutch drag
4) Engine
– Failed pilot bearing

Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 768 FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 768 FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 768 FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High

Read more →

Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 10 Rail Position Sensor: Abnormal Rate of Change

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the Transmission Harness.

The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Rail Position Sensor supply and the return voltage signal from the X-Y Rail Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 10 – Abnormal Rate of Change: The reported X-Y Rail Position Sensor return voltage signal changed by more than ±0.2 volts, or finger position moved by more than ±0.093 inches, while the transmission is engaged in gear.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 10: X-Y Rail Position Sensor return voltage signal remains consistent (within ±0.2 volts) while the transmission is in gear.

Possible Causes:
FMI 2, 4 or 10
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Rail Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High

Read more →

Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 2 Rail Position Sensor: Data Erratic

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the Transmission Harness.

The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Rail Position Sensor supply and the return voltage signal from the X-Y Rail Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU detects the X-Y Rail Position Sensor return voltage signal is outside of the 0.5–4.5-volt range for 1 second or longer

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 2: X-Y Rail Position Sensor return voltage signal stays within the 0.5–4.5-volt range for 1 second.

Possible Causes:
FMI 2, 4 or 10
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Rail Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SPN: 787 FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SID 54 SPN: FMI: 7 Inertia Brake Performance: Mechanical System Not Responding

Read more →

Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the Transmission Harness.

The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Rail Position Sensor supply and the return voltage signal from the X-Y Rail Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 3 – Voltage Above Normal or Shorted High: TECU detects the X-Y Rail Position Sensor supply voltage has exceeded 5.25 volts for 1 second or longer

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 3, 4: Supply voltage stays within the 4.75–5.25 volt range for 1 second

Possible Causes:
FMI 3
1) TECU
– Internal failure
2) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to power

Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SPN: 787 FMI: 7 Inertia Brake Performance: Mechanical System Not Responding

Read more →

Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the Transmission Harness.

The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Rail Position Sensor supply and the return voltage signal from the X-Y Rail Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 4 – Voltage Below Normal or Shorted Low: TECU detects the X-Y Rail Position Sensor supply voltage is below 4.75 volts for 1 second or longer

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear

Conditions to Set Fault Code Inactive:
FMI 3, 4: Supply voltage stays within the 4.75–5.25 volt range for 1 second

Possible Causes:
FMI 2, 4 or 10
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Rail Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 2 Rail Position Sensor: Data Erratic

Read more →

Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 10 Rail Position Sensor: Abnormal Rate of Change

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the Transmission Harness.

The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Rail Position Sensor supply and the return voltage signal from the X-Y Rail Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 10 – Abnormal Rate of Change: The reported X-Y Rail Position Sensor return voltage signal changed by more than ±0.2 volts, or finger position moved by more than ±0.093 inches, while the transmission is engaged in gear.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 10: X-Y Rail Position Sensor return voltage signal remains consistent (within ±0.2 volts) while the transmission is in gear.

Possible Causes:
FMI 2, 4 or 10
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Rail Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SPN: 787 FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SID 54 SPN: FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit

Read more →

Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 2 Rail Position Sensor: Data Erratic

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the Transmission Harness.

The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Rail Position Sensor supply and the return voltage signal from the X-Y Rail Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU detects the X-Y Rail Position Sensor return voltage signal is outside of the 0.5–4.5-volt range for 1 second or longer

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 2: X-Y Rail Position Sensor return voltage signal stays within the 0.5–4.5-volt range for 1 second.

Possible Causes:
FMI 2, 4 or 10
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Rail Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 45 PID: SPN: 787 FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SID 54 SPN: FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 768 FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit

Read more →

Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the
Transmission Harness.

The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Rail Position Sensor supply and the return voltage signal from the X-Y Rail Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 3 – Voltage Above Normal or Shorted High: TECU detects the X-Y Rail Position Sensor supply voltage has exceeded 5.25 volts for 1 second or longer

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 3, 4: Supply voltage stays within the 4.75–5.25 volt range for 1 second

Possible Causes:
FMI 3
1) TECU
– Internal failure
2) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to power

Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SPN: 787 FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SID 54 SPN: FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High

Read more →

Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Rail Position Sensor. The X-Y Rail Position Sensor reports lateral movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Rail Position Sensor is connected to the TECU via the
Transmission Harness.

The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Rail Position Sensor supply and the return voltage signal from the X-Y Rail Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 4 – Voltage Below Normal or Shorted Low: TECU detects the X-Y Rail Position Sensor supply voltage is below 4.75 volts for 1 second or longer

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear

Conditions to Set Fault Code Inactive:
FMI 3, 4: Supply voltage stays within the 4.75–5.25 volt range for 1 second

Possible Causes:
FMI 2, 4 or 10
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Rail Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SPN: 787 FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 45 PID: SID 54 SPN: FMI: 7 Inertia Brake Performance: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 769 FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low

Read more →