Eaton Fuller Advantage (2017) Fault Code: 36 PID: SPN: 639 FMI: 14 J1939 Engine Message: Special Instructions

Overview:
The J1939 Data Link is a Controller Area Network (CAN) communication bus. The Fuller Advantage transmission uses the J1939 Data Link to communicate with other ECUs (ABS, Engine, Body Controller, etc.). The Transmission Electronic Control Unit (TECU) sends and receives messages from other ECUs on the data link to determine when to initiate a shift, hold shifts, command engine torque to make shifts, as well as other functions. Proper operation of the J1939 Data Link is critical for shift performance. Fault Code 36 indicates the TECU can communicate with other ECUs on the J1939 Data Link but has lost communication
with the Engine ECU.

Detection:
TECU has either lost communication or received erratic signals from the Engine ECU over the J1939 Data Link and the TECU has not detected any low or weak battery system fault codes.

Conditions to Set Fault Code Active:
FMI 14 – Special Instructions: TECU has either lost communication or has received erratic signals from the Engine ECU over the J1939 Data Link for 5 seconds or longer.

Fallback:
FMI 14
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If vehicle is configured for the J1939 Start Enable feature the engine does not crank.
• If fault occurs during power up, the transmission requires the driver to manually synchronize shifts with the throttle.
• If fault occurs while driving, transmission remains in its current gear until the vehicle stops. Transmission then requires the driver to manually synchronize shifts with the throttle.

Conditions to Set Fault Code Inactive:
FMI 14: TECU receives messages across the data link for at least 10 seconds.

Possible Causes:
FMI 14
1) J1939 Data Link
– Wiring shorted to ground, shorted to power or open
– Excessive electrical noise
– Missing or additional terminating resistors
2) Engine ECU
– Internal failure
3) Vehicle Harness
– Wiring shorted to ground, shorted to power or open
4) Engine Harness
– Wiring shorted to ground, shorted to power or open

Eaton Fuller Advantage (2017) Fault Code: 36 PID: SID 231 SPN: FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SPN: 639 FMI: 2 J1939 Communication Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SID 231 SPN: FMI: 2 J1939 Communication Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 34 PID: SPN: 168 FMI: 14 Weak Battery Voltage Supply: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 34 PID: 168 SPN: FMI: 14 Weak Battery Voltage Supply: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 33 PID: SPN: 168 FMI: 4 Low Battery Voltage Supply: Voltage Below Normal or Shorted Low

Read more →

Eaton Fuller Advantage (2017) Fault Code: 36 PID: SID 231 SPN: FMI: 14 J1939 Engine Message: Special Instructions

Overview:
The J1939 Data Link is a Controller Area Network (CAN) communication bus. The Fuller Advantage transmission uses the J1939 Data Link to communicate with other ECUs (ABS, Engine, Body Controller, etc.). The Transmission Electronic Control Unit (TECU) sends and receives messages from other ECUs on the data link to determine when to initiate a shift, hold shifts, command engine torque to make shifts, as well as other functions. Proper operation of the J1939 Data Link is critical for shift performance. Fault Code 36 indicates the TECU can communicate with other ECUs on the J1939 Data Link but has lost communication
with the Engine ECU.

Detection:
TECU has either lost communication or received erratic signals from the Engine ECU over the J1939 Data Link and the TECU has not detected any low or weak battery system fault codes.

Conditions to Set Fault Code Active:
FMI 14 – Special Instructions: TECU has either lost communication or has received erratic signals from the Engine ECU over the J1939 Data Link for 5 seconds or longer.

Fallback:
FMI 14
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If vehicle is configured for the J1939 Start Enable feature the engine does not crank.
• If fault occurs during power up, the transmission requires the driver to manually synchronize shifts with the throttle.
• If fault occurs while driving, transmission remains in its current gear until the vehicle stops. Transmission then requires the driver to manually synchronize shifts with the throttle.

Conditions to Set Fault Code Inactive:
FMI 14: TECU receives messages across the data link for at least 10 seconds.

Possible Causes:
FMI 14
1) J1939 Data Link
– Wiring shorted to ground, shorted to power or open
– Excessive electrical noise
– Missing or additional terminating resistors
2) Engine ECU
– Internal failure
3) Vehicle Harness
– Wiring shorted to ground, shorted to power or open
4) Engine Harness
– Wiring shorted to ground, shorted to power or open

Eaton Fuller Advantage (2017) Fault Code: 35 PID: SPN: 639 FMI: 2 J1939 Communication Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SID 231 SPN: FMI: 2 J1939 Communication Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 34 PID: SPN: 168 FMI: 14 Weak Battery Voltage Supply: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 34 PID: 168 SPN: FMI: 14 Weak Battery Voltage Supply: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 33 PID: SPN: 168 FMI: 4 Low Battery Voltage Supply: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 33 PID: SPN: 168 FMI: 4 Low Battery Voltage Supply: Voltage Below Normal or Shorted Low

Read more →

Eaton Fuller Advantage (2017) Fault Code: 37 PID: SPN: 627 FMI: 5 Power Connect: Current Below Normal or Open Circuit

Overview:
The Fuller Advantage transmission is equipped with electronic components that require a high current. It is critical that the OEM power supply be able to deliver the proper voltage and current in these high-load situations for smooth and efficient shifting. Additional resistance introduced into the system can cause the supplied voltage to drop low enough to cause performance issues. Fault Code 37 indicates an excessive resistance between the power supply source (battery or starter) and the Transmission Electronic Control Unit (TECU).

Detection:
The TECU monitors the OEM power supply circuit for excessive resistance by measuring the voltage drop during high current demands, such as a shift request, and calculates a resistance value based on those demands. Fault Code 37 sets Active when the calculated resistance during high-load conditions exceeds 0.4 ohms and the TECU has not detected any low or weak battery system faults.

Conditions to Set Fault Code Active:
FMI 5 – Current Below Normal or Open Circuit: TECU calculates a resistance value based on high current demands and sets the fault code Active when that resistance exceeds 0.4 ohms.

Fallback:
No fallback mode is associated with this fault; however, transmission performance issues may be presented.

Conditions to Set Fault Code Inactive:
TECU calculates a resistance value below 0.4 ohms.

Possible Causes:
FMI 5
1) Vehicle Power Supply
– In-line fuse corrosion or loose connection
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
2) Vehicle Batteries
– Internal failure or high resistance

Eaton Fuller Advantage (2017) Fault Code: 37 PID: SID 251 SPN: FMI: 5 Power Connect: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SPN: 639 FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SID 231 SPN: FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SPN: 639 FMI: 2 J1939 Communication Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SID 231 SPN: FMI: 2 J1939 Communication Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 34 PID: SPN: 168 FMI: 14 Weak Battery Voltage Supply: Special Instructions

Read more →

Eaton Fuller Advantage (2017) Fault Code: 37 PID: SID 251 SPN: FMI: 5 Power Connect: Current Below Normal or Open Circuit

Overview:
The Fuller Advantage transmission is equipped with electronic components that require a high current. It is critical that the OEM power supply be able to deliver the proper voltage and current in these high-load situations for smooth and efficient shifting. Additional resistance introduced into the system can cause the supplied voltage to drop low enough to cause performance issues. Fault Code 37 indicates an excessive resistance between the power supply source (battery or starter) and the Transmission Electronic Control Unit (TECU).

Detection:
The TECU monitors the OEM power supply circuit for excessive resistance by measuring the voltage drop during high current demands, such as a shift request, and calculates a resistance value based on those demands. Fault Code 37 sets Active when the calculated resistance during high-load conditions exceeds 0.4 ohms and the TECU has not detected any low or weak battery system faults.

Conditions to Set Fault Code Active:
FMI 5 – Current Below Normal or Open Circuit: TECU calculates a resistance value based on high current demands and sets the fault code Active when that resistance exceeds 0.4 ohms.

Fallback:
No fallback mode is associated with this fault; however, transmission performance issues may be presented.

Conditions to Set Fault Code Inactive:
TECU calculates a resistance value below 0.4 ohms.

Possible Causes:
FMI 5
1) Vehicle Power Supply
– In-line fuse corrosion or loose connection
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
2) Vehicle Batteries
– Internal failure or high resistance

Eaton Fuller Advantage (2017) Fault Code: 36 PID: SPN: 639 FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SID 231 SPN: FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SPN: 639 FMI: 2 J1939 Communication Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SID 231 SPN: FMI: 2 J1939 Communication Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 34 PID: SPN: 168 FMI: 14 Weak Battery Voltage Supply: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 34 PID: 168 SPN: FMI: 14 Weak Battery Voltage Supply: Special Instructions

Read more →

Eaton Fuller Advantage (2017) Fault Code: 41 PID: SPN: 768 FMI: 7 Range Failed to Engage: Mechanical System Not Responding

Overview:
Most Heavy-Duty Fuller Advantage Transmission models are equipped with a 2-speed range system in the auxiliary case. The ability to select an auxiliary range gear independently from a main case gear allows the transmission twice the number of overall gear ratios. Main case gearing can be used once in auxiliary low range and again in auxiliary high range. The range system is equipped with a Range Solenoid Valve. The Range Solenoid Valve is an electric-over-air solenoid that is controlled by the Transmission Electronic Control Unit (TECU), replacing the Shift Knob-Slave Valve system found on Eaton Fuller manual transmissions. During operation, the solenoid directs air pressure to either port in the Range Cylinder based on the need to activate the auxiliary low range or high range gearing. The applied air pressure directs the fore-and-aft movement of the Range Piston within the Range Cylinder, facilitating the mechanical engagement of the Range Synchronizer into either low or high range. Fault Code 41 indicates the transmission is unable to complete a range shift.

Detection:
When toggling the Range Solenoid Valve, the TECU verifies the new range position by calculating the overall transmission gear ratio, using the Main Shaft and Output Shaft Speed Sensor signals. If the calculated ratio does not match the expected ratio for the new range position, the auxiliary case gearing did not change as expected and the TECU sets the fault code Active. The TECU detected a range system failure, but was unable to detect the specific root cause.

Conditions to Set Fault Code Active:
FMI 7 – Mechanical System Not Responding: Transmission is either stuck in its current range position or it cannot engage the desired range position after five consecutive attempts.

Fallback:
FMI 7
• Transmission remains in the range where the failure occurred.
• Transmission may attempt to shift into low range when the vehicle comes to a stop.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 7: Transmission successfully attains the requested range for 2 seconds.

Possible Causes:
FMI 7
1) Vehicle Air System
– Low vehicle air pressure
– Contamination in air supply
– Air leaks
– Filter-Regulator failure
2) Range Solenoid Valve
– Mechanical failure
3) Mechanical Transmission
– Range Synchronizer failure
– Range Cylinder, Piston or Yoke wear or damage
– Range Cover Gasket failure
– Tone Wheel damage
– Failed auxiliary case components
4) Main Shaft Speed Sensor
– Internal failure
5) Output Shaft Sensor
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 41 PID: SID 36 SPN: FMI: 7 Range Failed to Engage: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 41 PID: SID 35 SPN: FMI: 7 Range Failed to Engage: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 37 PID: SPN: 627 FMI: 5 Power Connect: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 37 PID: SID 251 SPN: FMI: 5 Power Connect: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SPN: 639 FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SID 231 SPN: FMI: 14 J1939 Engine Message: Special Instructions

Read more →

Eaton Fuller Advantage (2017) Fault Code: 41 PID: SPN: 769 FMI: 7 Range Failed to Engage: Mechanical System Not Responding

Overview:
Most Heavy-Duty Fuller Advantage Transmission models are equipped with a 2-speed range system in the auxiliary case. The ability to select an auxiliary range gear independently from a main case gear allows the transmission twice the number of overall gear ratios. Main case gearing can be used once in auxiliary low range and again in auxiliary high range. The range system is equipped with a Range Solenoid Valve. The Range Solenoid Valve is an electric-over-air solenoid that is controlled by the Transmission Electronic Control Unit (TECU), replacing the Shift Knob-Slave Valve system found on Eaton Fuller manual transmissions. During operation, the solenoid directs air pressure to either port in the Range Cylinder based on the need to activate the auxiliary low range or high range gearing. The applied air pressure directs the fore-and-aft movement of the Range Piston within the Range Cylinder, facilitating the mechanical engagement of the Range Synchronizer into either low or high range. Fault Code 41 indicates the transmission is unable to complete a range shift.

Detection:
When toggling the Range Solenoid Valve, the TECU verifies the new range position by calculating the overall transmission gear ratio, using the Main Shaft and Output Shaft Speed Sensor signals. If the calculated ratio does not match the expected ratio for the new range position, the auxiliary case gearing did not change as expected and the TECU sets the fault code Active. The TECU detected a range system failure, but was unable to detect the specific root cause.

Conditions to Set Fault Code Active:
FMI 7 – Mechanical System Not Responding: Transmission is either stuck in its current range position or it cannot engage the desired range position after five consecutive attempts.

Fallback:
FMI 7
• Transmission remains in the range where the failure occurred.
• Transmission may attempt to shift into low range when the vehicle comes to a stop.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 7: Transmission successfully attains the requested range for 2 seconds.

Possible Causes:
FMI 7
1) Vehicle Air System
– Low vehicle air pressure
– Contamination in air supply
– Air leaks
– Filter-Regulator failure
2) Range Solenoid Valve
– Mechanical failure
3) Mechanical Transmission
– Range Synchronizer failure
– Range Cylinder, Piston or Yoke wear or damage
– Range Cover Gasket failure
– Tone Wheel damage
– Failed auxiliary case components
4) Main Shaft Speed Sensor
– Internal failure
5) Output Shaft Sensor
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 41 PID: SPN: 768 FMI: 7 Range Failed to Engage: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 41 PID: SID 36 SPN: FMI: 7 Range Failed to Engage: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 41 PID: SID 35 SPN: FMI: 7 Range Failed to Engage: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 37 PID: SPN: 627 FMI: 5 Power Connect: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 37 PID: SID 251 SPN: FMI: 5 Power Connect: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SPN: 639 FMI: 14 J1939 Engine Message: Special Instructions

Read more →

Eaton Fuller Advantage (2017) Fault Code: 41 PID: SID 35 SPN: FMI: 7 Range Failed to Engage: Mechanical System Not Responding

Overview:
Most Heavy-Duty Fuller Advantage Transmission models are equipped with a 2-speed range system in the auxiliary case. The ability to select an auxiliary range gear independently from a main case gear allows the transmission twice the number of overall gear ratios. Main case gearing can be used once in auxiliary low range and again in auxiliary high range. The range system is equipped with a Range Solenoid Valve. The Range Solenoid Valve is an electric-over-air solenoid that is controlled by the Transmission Electronic Control Unit (TECU), replacing the Shift Knob-Slave Valve system found on Eaton Fuller manual transmissions. During operation, the solenoid directs air pressure to either port in the Range Cylinder based on the need to activate the auxiliary low range or high range gearing. The applied air pressure directs the fore-and-aft movement of the Range Piston within the Range Cylinder, facilitating the mechanical engagement of the Range Synchronizer into either low or high range. Fault Code 41 indicates the transmission is unable to complete a range shift.

Detection:
When toggling the Range Solenoid Valve, the TECU verifies the new range position by calculating the overall transmission gear ratio, using the Main Shaft and Output Shaft Speed Sensor signals. If the calculated ratio does not match the expected ratio for the new range position, the auxiliary case gearing did not change as expected and the TECU sets the fault code Active. The TECU detected a range system failure, but was unable to detect the specific root cause.

Conditions to Set Fault Code Active:
FMI 7 – Mechanical System Not Responding: Transmission is either stuck in its current range position or it cannot engage the desired range position after five consecutive attempts.

Fallback:
FMI 7
• Transmission remains in the range where the failure occurred.
• Transmission may attempt to shift into low range when the vehicle comes to a stop.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 7: Transmission successfully attains the requested range for 2 seconds.

Possible Causes:
FMI 7
1) Vehicle Air System
– Low vehicle air pressure
– Contamination in air supply
– Air leaks
– Filter-Regulator failure
2) Range Solenoid Valve
– Mechanical failure
3) Mechanical Transmission
– Range Synchronizer failure
– Range Cylinder, Piston or Yoke wear or damage
– Range Cover Gasket failure
– Tone Wheel damage
– Failed auxiliary case components
4) Main Shaft Speed Sensor
– Internal failure
5) Output Shaft Sensor
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 37 PID: SPN: 627 FMI: 5 Power Connect: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 37 PID: SID 251 SPN: FMI: 5 Power Connect: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SPN: 639 FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SID 231 SPN: FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SPN: 639 FMI: 2 J1939 Communication Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SID 231 SPN: FMI: 2 J1939 Communication Link: Data Erratic

Read more →

Eaton Fuller Advantage (2017) Fault Code: 41 PID: SID 36 SPN: FMI: 7 Range Failed to Engage: Mechanical System Not Responding

Overview:
Most Heavy-Duty Fuller Advantage Transmission models are equipped with a 2-speed range system in the auxiliary case. The ability to select an auxiliary range gear independently from a main case gear allows the transmission twice the number of overall gear ratios. Main case gearing can be used once in auxiliary low range and again in auxiliary high range. The range system is equipped with a Range Solenoid Valve. The Range Solenoid Valve is an electric-over-air solenoid that is controlled by the Transmission Electronic Control Unit (TECU), replacing the Shift Knob-Slave Valve system found on Eaton Fuller manual transmissions. During operation, the solenoid directs air pressure to either port in the Range Cylinder based on the need to activate the auxiliary low range or high range gearing. The applied air pressure directs the fore-and-aft movement of the Range Piston within the Range Cylinder, facilitating the mechanical engagement of the Range Synchronizer into either low or high range. Fault Code 41 indicates the transmission is unable to complete a range shift.

Detection:
When toggling the Range Solenoid Valve, the TECU verifies the new range position by calculating the overall transmission gear ratio, using the Main Shaft and Output Shaft Speed Sensor signals. If the calculated ratio does not match the expected ratio for the new range position, the auxiliary case gearing did not change as expected and the TECU sets the fault code Active. The TECU detected a range system failure, but was unable to detect the specific root cause.

Conditions to Set Fault Code Active:
FMI 7 – Mechanical System Not Responding: Transmission is either stuck in its current range position or it cannot engage the desired range position after five consecutive attempts.

Fallback:
FMI 7
• Transmission remains in the range where the failure occurred.
• Transmission may attempt to shift into low range when the vehicle comes to a stop.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 7: Transmission successfully attains the requested range for 2 seconds.

Possible Causes:
FMI 7
1) Vehicle Air System
– Low vehicle air pressure
– Contamination in air supply
– Air leaks
– Filter-Regulator failure
2) Range Solenoid Valve
– Mechanical failure
3) Mechanical Transmission
– Range Synchronizer failure
– Range Cylinder, Piston or Yoke wear or damage
– Range Cover Gasket failure
– Tone Wheel damage
– Failed auxiliary case components
4) Main Shaft Speed Sensor
– Internal failure
5) Output Shaft Sensor
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 41 PID: SID 35 SPN: FMI: 7 Range Failed to Engage: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 37 PID: SPN: 627 FMI: 5 Power Connect: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 37 PID: SID 251 SPN: FMI: 5 Power Connect: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SPN: 639 FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 36 PID: SID 231 SPN: FMI: 14 J1939 Engine Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 35 PID: SPN: 639 FMI: 2 J1939 Communication Link: Data Erratic

Read more →

Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 768 FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High

Overview:
Most Fuller Advantage Transmission models are equipped with a 2-speed range system in the auxiliary case. The ability to select an auxiliary range gear independently from a main case gear allows the transmission twice the number of overall gear ratios by using the main case gearing once in auxiliary low range and again in auxiliary high range.

The range system is equipped with a Range Solenoid Valve. The Range Solenoid Valve is an electric-over-air solenoid that is controlled by the Transmission Electronic Control Unit (TECU), replacing the Shift Knob-Slave Valve system found on Eaton Fuller manual transmissions.

During operation, the solenoid directs air pressure to either port in the Range Cylinder based on the need to activate the auxiliary low range or high range gearing. The applied air pressure directs the fore-and-aft movement of the Range Piston within the Range Cylinder, facilitating the mechanical engagement of the Range Synchronizer into either low or high range. Auxiliary case gear changes are physically engaged and disengaged to the transmission main case through the Range Synchronizer.

Fault Code 43 indicates an electrical fault within the Range Solenoid Valve circuit.

Detection:
The TECU can detect an open circuit or a short to ground when the Range Solenoid Valve is on. The TECU can detect a short to power when the Range Solenoid Valve is off.

Conditions to Set Fault Code Active:
FMI 3 – Voltage Above Normal or Shorted High: With the solenoid off, the TECU detects high voltage in the Range Solenoid Valve high side driver circuit for 1 second

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).

Possible Causes:
FMI 3
1) Transmission Harness
– Wiring shorted to power
2) TECU
– Internal short to power
3) Engine cranks and starts.
4) High side coil failure (SID 35/SPN 768).
– If the failure occurs in high range, the transmission shifts through all high range gears and shifts to low range when vehicle speed is appropriate; however, the transmission is then restricted to shifting in all low range gears only.
– If the failure occurs in low range, the transmission shifts through all low range gears but will not shift to high range.
5) Low side coil failure (SID 36/SPN 769).
– If the failure occurs in high range, the transmission shifts through all high range gears but will not shift into low range.
– If the failure occurs in low range, the transmission shifts through all low range gears but will not shift to high range.

Conditions to Set Fault Code Inactive:
All FMIs: An electrical short or open circuit is not detected for 2 seconds.

Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 36 SPN: FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 36 SPN: FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 36 SPN: FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 35 SPN: FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 35 SPN: FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 35 SPN: FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High

Read more →

Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 768 FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low

Overview:
Most Fuller Advantage Transmission models are equipped with a 2-speed range system in the auxiliary case. The ability to select an auxiliary range gear independently from a main case gear allows the transmission twice the number of overall gear ratios by using the main case gearing once in auxiliary low range and again in auxiliary high range. The range system is equipped with a Range Solenoid Valve.

The Range Solenoid Valve is an electric-over-air solenoid that is controlled by the Transmission Electronic Control Unit (TECU), replacing the Shift Knob-Slave Valve system found on Eaton Fuller manual transmissions.

During operation, the solenoid directs air pressure to either port in the Range Cylinder based on the need to activate the auxiliary low range or high range gearing. The applied air pressure directs the fore-and-aft movement of the Range Piston within the Range Cylinder, facilitating the mechanical engagement of the Range Synchronizer into either low or high range. Auxiliary case gear changes are physically engaged and disengaged to the transmission main case through the Range Synchronizer.

Fault Code 43 indicates an electrical fault within the Range Solenoid Valve circuit.

Detection:
The TECU can detect an open circuit or a short to ground when the Range Solenoid Valve is on. The TECU can detect a short to power when the Range Solenoid Valve is off.

Conditions to Set Fault Code Active:
FMI 4 – Voltage Below Normal or Shorted Low: With the solenoid on, the TECU detects low voltage in the Range Solenoid Valve low side driver circuit for 1 second

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine cranks and starts.
• High side coil failure (SID 35/SPN 768).
– If the failure occurs in high range, the transmission shifts through all high range gears and shifts to low range when vehicle speed is appropriate; however, the transmission is then
restricted to shifting in all low range gears only.
– If the failure occurs in low range, the transmission shifts through all low range gears but will not shift to high range.
• Low side coil failure (SID 36/SPN 769).
– If the failure occurs in high range, the transmission shifts through all high range gears but will not shift into low range.
– If the failure occurs in low range, the transmission shifts through all low range gears but will not shift to high range.

Conditions to Set Fault Code Inactive:
All FMIs: An electrical short or open circuit is not detected for 2 second

Possible Causes:
FMI 4
1) Transmission Harness
– Wiring shorted to ground
2) Range Solenoid Valve
– Internal short to ground
3) TECU
– Internal short to ground

Eaton Fuller Advantage (2017) Fault Code: 43 PID: SPN: 768 FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 36 SPN: FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 36 SPN: FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 36 SPN: FMI: 3 Range Solenoid Valve: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 35 SPN: FMI: 5 Range Solenoid Valve: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 43 PID: SID 35 SPN: FMI: 4 Range Solenoid Valve: Voltage Below Normal or Shorted Low