Skip to content

Telegram : @Diezel365

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 1 (ACM) Diesel Exhaust Fluid Tank Temperature – Low

NOTE: This code sets when the diesel exhaust fluid (DEF) tank temperature does not increase 0.5°C (0.9°F) within 300 seconds after the DEF tank coolant valve has bn commanded on.

DESCRIPTION:DEF tank temperature – low.

MONITORED PARAMETER:DEF tank temperature.

TYPICAL ENABLING CONDITIONS:1. Coolant valve commanded open.2. Coolant temperature greater than 70°C (158°F).3. Ambient temperature less than -1°C (30°F) as measured by the ACM.

MONITOR SEQUENCE:None

EXECUTION FREQUENCY:Continuous when enabling conditions met.

TYPICAL DURATION:30 minutes

DASH LAMPS:MIL

VERIFICATION:Parked regeneration

NOTE: If any cooling system codes present, fix this first.

NOTE: If codes 3363-3, 3363-4, or 3363-5 active, fix those first.

PROBABLE CAUSES:1. Coolant line from engine to DEF pump.2. DEF tank header assy.3. DEF tank header assy harness/connector.

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 0 (ACM) Diesel Exhaust Fluid Tank Temperature – High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 8 (ACM) Diesel Exhaust Fluid Metering Unit – Exceeding Unclog Attempts
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 7 (ACM) Diesel Exhaust Fluid Metering Unit – Unable to Clear Restriction
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 5 (ACM) Diesel Exhaust Fluid Dosing Valve Circuit Failed Open
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 4 (ACM) Diesel Exhaust Fluid Metering Valve Circuit Failed Low
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 3 (ACM) Diesel Exhaust Fluid Dosing Valve Circuit Failed High