Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 196 (2 Wire) PID: PID 2558 SPN: 111 FMI: 4 Coolant Level Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe coolant level sensor is a switch and is used to measure the level of the engine coolant in the radiator top tank. The coolant level sensor is immersed in the coolant and returns a different signal voltage when immersed in coolant versus being out of coolant. The engine control module (ECM) monitors the change in the signal voltage to determine the level of the engine coolant.

Component LocationThe engine coolant level sensor is typically located in the radiator top tank or surge tank. Refer to the OEM service manual for the location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the coolant level signal voltage was less than a calibratible value for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.No engine protection will be available for low coolant level.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Open signal circuit in the engine harness, connectors, or sensorSignal circuit shorted to ground in the harness, sensor or connectorsDamaged sensor.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 195 (3 Wire) PID: PID 111 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 195 (2 Wire) PID: PID 2559 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 187 PID: SID 211 SPN: 3510 FMI: 4 Sensor Supply 2 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 175 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 155 PID: PID 105 SPN: 105 FMI: 0 Intake Manifold 1 Temperature- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 154 PID: PID 105 SPN: 105 FMI: 4 Intake Manifold 1 Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 196 (3 Wire) PID: PID 111 SPN: 111 FMI: 4 Coolant Level Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe coolant level sensor is a switch and is used to measure the level of the engine coolant in the radiator top tank. The coolant level sensor is immersed in the coolant and returns a different signal voltage when immersed in coolant versus being out of coolant. The engine control module (ECM) monitors the change in the signal voltage to determine the level of the engine coolant.

Component LocationThe engine coolant level sensor is typically located in the radiator top tank or surge tank. Refer to the OEM service manual for the location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the coolant level signal voltage was less than 0.58-VDC for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.No engine protection will be available for low coolant level.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A short circuit to ground in the OEM harnessAn open circuit in the OEM harnessA malfunctioning engine coolant level sensor

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 196 (2 Wire) PID: PID 2558 SPN: 111 FMI: 4 Coolant Level Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 195 (3 Wire) PID: PID 111 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 195 (2 Wire) PID: PID 2559 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 187 PID: SID 211 SPN: 3510 FMI: 4 Sensor Supply 2 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 175 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 155 PID: PID 105 SPN: 105 FMI: 0 Intake Manifold 1 Temperature- Data Valid But Above Normal Operating Range- Most Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1961 PID: SID 146 SPN: 2791 FMI: 15 EGR Valve Control Circuit Calculated Over Temperature- Data Valid But Above Normal Operational Range- Least Severe Level

Circuit DescriptionThe exhaust gas recirculation (EGR) valve is controlled by a brushless motor located on top of the EGR valve. The EGR valve motor uses three different motor legs to move the valve through its range of motion. The ECM uses the EGR motor A, B, and C wires to command the EGR valve to the appropriate position in order to meet EGR flow targets.The EGR valve motor contains three position sensors that detect the location of the EGR valve. These sensors report the position of the valve back to the ECM over the EGR valve position A, B, and C wires.

The EGR valve motor contains three position sensors that detect the location of the EGR valve. These sensors report the position of the valve back to the ECM over the EGR valve position A, B, and C wires.

Component LocationThe EGR valve device driver is internal to the ECM and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the temperature of the EGR valve driver internal to the ECM was greater than 150°C [302°F].

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code may be inactive when the vehicle is in the shop because the EGR valve driver temperature has cooled down. Therefore, troubleshoot multiple inactive counts of this fault code as an active fault code.

Possible causes of this fault code include:

Malfunctioning ECM.

Possible Cause:1) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1943 PID: SPN: 3555 FMI: 17 Ambient Air Density- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1942 PID: PID 101 SPN: 101 FMI: 2 Crankcase Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1938 PID: SID 212 SPN: 3597 FMI: 18 ECU Power Output Supply Voltage 1- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1932 PID: SID 382 SPN: 3556 FMI: 2 Aftertreatment Doser- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1928 PID: SPN: 1928 FMI: 4 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1927 PID: SPN: 3480 FMI: 3 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1962 PID: SID 27 SPN: 641 FMI: 15 VGT Actuator Driver Over Temperature (Calculated)- Data Valid But Above Normal Operational Range- Least Severe Level

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe internal temperature of the Variable Geometry Turbocharger (VGT) actuator exceeded 125°C [257°F] continuously for 30 minutes.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code will be inactive when the vehicle is in the shop because the VGT actuator temperature has cooled down. Troubleshoot multiple inactive counts of this fault code as an active fault code.

Also check for exhaust leaks blowing on the VGT actuator. Repair any external leaks.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1961 PID: SID 146 SPN: 2791 FMI: 15 EGR Valve Control Circuit Calculated Over Temperature- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1943 PID: SPN: 3555 FMI: 17 Ambient Air Density- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1942 PID: PID 101 SPN: 101 FMI: 2 Crankcase Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1938 PID: SID 212 SPN: 3597 FMI: 18 ECU Power Output Supply Voltage 1- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1932 PID: SID 382 SPN: 3556 FMI: 2 Aftertreatment Doser- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1928 PID: SPN: 1928 FMI: 4 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1963 PID: SID 332 SPN: 3482 FMI: 7 Aftertreatment Fuel Shutoff Valve 1- Mechanical System Not Responding Porperly or Out of Adjustment

Circuit DescriptionBefore active regeneration of the aftertreatment diesel particulate filter, a diagnostic test on the system is performed. The aftertreatment fuel injector opens and relieves fuel pressure in the line. The aftertreatment fuel pressure sensor must be reading atmospheric pressure at this point in the test. The aftertreatment fuel injector closes and the aftertreatment purge air actuator opens. This pressurizes the aftertreatment fuel system to vehicle air pressure. The diagnostic then checks to make sure the aftertreatment fuel pressure sensor is reading vehicle air pressure. The aftertreatment fuel shutoff valve then opens and allows pressurized fuel to enter the system. The aftertreatment fuel injector then opens and primes the system by purging the air from the line. The aftertreatment fuel shutoff valve and aftertreatment fuel injector then close and trap the fuel between the aftertreatment fuel shutoff valve and the aftertreatment fuel injector. The diagnostic checks to make sure the system maintains fuel pressure.

Component LocationThe aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the DiagnosticsThis diagnostic runs during active regeneration of the aftertreatment diesel particulate filter.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment fuel pressure sensor was reading lower than a calibratible threshold when the aftertreatment fuel shutoff valve was commanded open.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active regeneration of the aftertreatment diesel particulate filter will be disabled unitl the next key cycle.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and perform the INSITE™ electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Stuck closed aftertreatment fuel shutoff valveA missing or leaking fuel supply line to the aftertreatment fuel shutoff manifoldA plugged fuel filterA malfunctioning fuel pump gear pump.

Possible Cause:1) Fuel pump gear pump failure2) Fuel Filter failure3) Aftertreatment fuel shutoff valve failure4) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1962 PID: SID 27 SPN: 641 FMI: 15 VGT Actuator Driver Over Temperature (Calculated)- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1961 PID: SID 146 SPN: 2791 FMI: 15 EGR Valve Control Circuit Calculated Over Temperature- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1943 PID: SPN: 3555 FMI: 17 Ambient Air Density- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1942 PID: PID 101 SPN: 101 FMI: 2 Crankcase Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1938 PID: SID 212 SPN: 3597 FMI: 18 ECU Power Output Supply Voltage 1- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1932 PID: SID 382 SPN: 3556 FMI: 2 Aftertreatment Doser- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 197 PID: PID 2560 SPN: 111 FMI: 18 Coolant Level- Data Valid But Below Normal Operational Range- Moderately Severe Level

Circuit DescriptionThe coolant level sensor is a switch and is used to measure the level of the engine coolant in the radiator top tank. The coolant level sensor is immersed in the coolant and returns a different signal voltage when immersed in coolant versus being out of coolant. The engine control module (ECM) monitors the change in the signal voltage to determine the level of the engine coolant.

Component LocationThe engine coolant level sensor is typically located in the radiator top tank or surge tank. Refer to the OEM service manual for the location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the coolant level sensor signal voltage was higher than 3-VDC for more than 30 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The torque output of the engine will be reduced.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code goes active when the coolant level inside the radiator top tank or surge tank drops below the sensor level. Fill the top tank with coolant.

If this fault code is active and the coolant level is not low, disconnect the coolant level sensor and check the connectors for traces of coolant. If coolant is found at the electrical connectors, the sensor has malfunctioned and must be replaced.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 196 (3 Wire) PID: PID 111 SPN: 111 FMI: 4 Coolant Level Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 196 (2 Wire) PID: PID 2558 SPN: 111 FMI: 4 Coolant Level Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 195 (3 Wire) PID: PID 111 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 195 (2 Wire) PID: PID 2559 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 187 PID: SID 211 SPN: 3510 FMI: 4 Sensor Supply 2 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 175 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1974 PID: PID 101 SPN: 101 FMI: 15 Crankcase Pressure- Data valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe crankcase pressure sensor is used to monitor the pressure inside the crankcase. The engine control module (ECM) supplies the crankcase pressure sensor a 5 volt reference voltage. When the crankcase pressure is low, the sensor signal voltage is low. When the crankcase pressure is high, the sensor signal voltage is near the 5 volt reference voltage. The ECM monitors the crankcase pressure signal circuit voltage to calculate the pressure of the air within the crankcase.

Component LocationThe crankcase pressure sensor is located near the crankcase ventilation filter.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe engine control module (ECM) detected the crankcase pressure in the breather tube was greater than a calibratable value.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.Use INSITE™ electronic service tool “Data Monitor/Logger” feature to monitor “Crankcase Pressure” with the engine running at idle. If the crankcase pressure reading is below 7.0 in H20, the repair has been validated.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.

Shop TalkIf this fault code is active, the crankcase breather element may need to be replaced.

Possible Cause:1) Crankcase Pressure sensor failure2) Crankcase breather filter failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1963 PID: SID 332 SPN: 3482 FMI: 7 Aftertreatment Fuel Shutoff Valve 1- Mechanical System Not Responding Porperly or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1962 PID: SID 27 SPN: 641 FMI: 15 VGT Actuator Driver Over Temperature (Calculated)- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1961 PID: SID 146 SPN: 2791 FMI: 15 EGR Valve Control Circuit Calculated Over Temperature- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1943 PID: SPN: 3555 FMI: 17 Ambient Air Density- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1942 PID: PID 101 SPN: 101 FMI: 2 Crankcase Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1938 PID: SID 212 SPN: 3597 FMI: 18 ECU Power Output Supply Voltage 1- Data Valid But Below Normal Operational Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1976 PID: SID 27 SPN: 641 FMI: 15 VGT Actuator Driver Temperature- Data Valid But Above Normal Operating Range- Least Severe Level

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe internal temperature of the Variable Geometry Turbocharger (VGT) actuator exceeded 125°C [257°F] continuously for 30 minutes.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code will be inactive when the vehicle is in the shop because the VGT actuator temperature has cooled down. Troubleshoot multiple inactive counts of this fault code as an active fault code.

Also check for exhaust leaks blowing on the VGT actuator. Repair any external leaks.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1974 PID: PID 101 SPN: 101 FMI: 15 Crankcase Pressure- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1963 PID: SID 332 SPN: 3482 FMI: 7 Aftertreatment Fuel Shutoff Valve 1- Mechanical System Not Responding Porperly or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1962 PID: SID 27 SPN: 641 FMI: 15 VGT Actuator Driver Over Temperature (Calculated)- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1961 PID: SID 146 SPN: 2791 FMI: 15 EGR Valve Control Circuit Calculated Over Temperature- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1943 PID: SPN: 3555 FMI: 17 Ambient Air Density- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1942 PID: PID 101 SPN: 101 FMI: 2 Crankcase Pressure- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1977 PID: SID 382 SPN: 3556 FMI: 5 Aftertreatment Doser Circuit- Current Below Normal or Open Circuit

Circuit DescriptionThe aftertreatment fuel injector is electronically controlled by the engine electronic control module (ECM) through a pulse width modulated (PWM) signal. The amount of fuel injected is determined by how long the PWM signal to the injector is on.

Component LocationThe aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a circuit error within the aftertreatment fuel injector circuit.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active regeneration of the aftertreatment diesel particulate filter will be disabled unitl the next key cycle.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and perform the INSITE™ electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

An open circuit in the supply or return wire in the engine harnessAn open circuit in the aftertreatment fuel injector solenoidA short circuit to ground in the engine harnessA short circuit to voltage source in the engine harnessHigh resistance in the aftertreatment fuel injector solenoidAn extremely low resistance in the aftertreatment fuel injector solenoidA damaged ECM.

Possible Cause:1) Aftertreatment fuel Injector failure2) Wiring harness failure3) Engine harness failure4) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1976 PID: SID 27 SPN: 641 FMI: 15 VGT Actuator Driver Temperature- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1974 PID: PID 101 SPN: 101 FMI: 15 Crankcase Pressure- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1963 PID: SID 332 SPN: 3482 FMI: 7 Aftertreatment Fuel Shutoff Valve 1- Mechanical System Not Responding Porperly or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1962 PID: SID 27 SPN: 641 FMI: 15 VGT Actuator Driver Over Temperature (Calculated)- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1961 PID: SID 146 SPN: 2791 FMI: 15 EGR Valve Control Circuit Calculated Over Temperature- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1943 PID: SPN: 3555 FMI: 17 Ambient Air Density- Data Valid But Below Normal Operational Range- Least Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1981 PID: SPN: 3936 FMI: 15 Aftertreatment Diesel Particulate Filter System- Data Valid But Above Normal Operational Range- Least Severe Level

Circuit DescriptionThe engine aftertreatment system monitors the soot load in the aftertreatment diesel particulate filter. Under normal operating conditions, the aftertreatment diesel particulate filter is self-cleaning, where soot is converted to carbon dioxide, nitrogen, and water. Under light load operating conditions, it can be necessary to perform a stationary regeneration of the aftertreatment diesel particulate filter. The soot load in the aftertreatment diesel particulate filter is estimated, using the aftertreatment differential pressure sensor and the calculated soot output of the engine.

Component LocationThe aftertreatment diesel particulate filter is located in the exhaust system and is installed by the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the diesel particulate filter is plugged or that the differential pressure across the diesel particulate filter was greater than the maximum limits.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

The aftertreatment diesel particulate filter can be plugged with ash.The engine has been operating in light load conditions that prevent exhaust gas temperatures from being high enough to actively regenerate the aftertreatment particulate trap.An engine malfunction that is elevating the engine smoke output.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Aftertreatment DPF differential pressure sensor failure2) DPF failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1977 PID: SID 382 SPN: 3556 FMI: 5 Aftertreatment Doser Circuit- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1976 PID: SID 27 SPN: 641 FMI: 15 VGT Actuator Driver Temperature- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1974 PID: PID 101 SPN: 101 FMI: 15 Crankcase Pressure- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1963 PID: SID 332 SPN: 3482 FMI: 7 Aftertreatment Fuel Shutoff Valve 1- Mechanical System Not Responding Porperly or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1962 PID: SID 27 SPN: 641 FMI: 15 VGT Actuator Driver Over Temperature (Calculated)- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1961 PID: SID 146 SPN: 2791 FMI: 15 EGR Valve Control Circuit Calculated Over Temperature- Data Valid But Above Normal Operational Range- Least Severe Level

Read more →