Cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1 – Data Erratic, Intermittent, or Incorrect

Circuit DescriptionBefore active regeneration of the aftertreatment diesel particulate filter, a diagnostic test on the system is performed. The aftertreatment fuel injector opens and relieves fuel pressure in the line. The aftertreatment fuel pressure sensor must be reading atmospheric pressure at this point in the test. The aftertreatment fuel injector closes and the aftertreatment purge air actuator opens. This pressurizes the aftertreatment fuel system to vehicle air pressure. The diagnostic then checks to make sure the aftertreatment fuel pressure sensor is reading vehicle air pressure. The aftertreatment fuel shutoff valve then opens and allows pressurized fuel to enter the system. The aftertreatment fuel injector then opens and primes the system by purging the air from the line. The aftertreatment fuel shutoff valve and aftertreatment fuel injector then close and trap the fuel between the aftertreatment fuel shutoff valve and the aftertreatment fuel injector. The diagnostic checks to make sure the system maintains fuel pressure.

Component LocationThe aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the DiagnosticsThis diagnostic runs during active regeneration of the aftertreatment diesel particulate filter.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected an internally leaking aftertreatment fuel shutoff valve, aftertreatment purge air actuator, or a stuck closed aftertreatment fuel injector.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active regeneration of the aftertreatment diesel particulate filter will be disabled unitl the next key cycle.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and perform the INSITE™ electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Internal leak of the aftertreatment fuel shutoff valve allowing fuel pressure to leak past the shutoff valveInternal leak of the aftertreatment purge air actuatorStuck closed, plugged, or clogged aftertreatment fuel injector.

Possible Cause:1) Aftertreatment Fuel Pressure Sensor failure2) Aftertreatment Injector failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1924 PID: SID 334 SPN: 3482 FMI: 4 Aftertreatment Fuel Shutoff Valve 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1923 PID: SID 334 SPN: 3482 FMI: 3 Aftertreatment Fuel Shutofff Valve 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1922 PID: SID 324 SPN: 3251 FMI: 0 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1921 PID: SID 324 SPN: 3251 FMI: 16 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1898 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1897 PID: SID 27 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1926 PID: SID 332 SPN: 3480 FMI: 2 Aftertreatment Fuel Pressure Sensor- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment fuel pressure sensor is used to monitor the fuel pressure into the aftertreatment system. The engine control module (ECM) supplies the aftertreatment fuel pressure sensor a 5 volt reference voltage. When the fuel pressure is low, the sensor signal voltage is low. When the fuel pressure is high, the sensor signal voltage is near the 5 volt reference voltage. The ECM monitors the aftertreatment fuel pressure signal circuit voltage to calculate the pressure of the fuel within the aftertreatment system.

Component LocationThe aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the DiagnosticsThis diagnostic runs during active regeneration of the aftertreatment diesel particulate filter.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment fuel pressure sensor was reading an erratic value, or the aftertreatment fuel pressure reading was not changing with the engine operating conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the aftertreatment fuel pressure sensor reading is used.Active regeneration of the aftertreatment diesel particulate filter will be disabled unitl the next key cycle.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and perform the INSITE™ electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning in-range aftertreatment fuel pressure sensorA plugged fuel filterA malfunctioning fuel pump gear pump.

Possible Cause:1) Fuel pump gear pump failure2) Fuel filter failure3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1 – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1924 PID: SID 334 SPN: 3482 FMI: 4 Aftertreatment Fuel Shutoff Valve 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1923 PID: SID 334 SPN: 3482 FMI: 3 Aftertreatment Fuel Shutofff Valve 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1922 PID: SID 324 SPN: 3251 FMI: 0 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1921 PID: SID 324 SPN: 3251 FMI: 16 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1898 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1927 PID: SPN: 3480 FMI: 3 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment fuel pressure sensor is used to monitor the fuel pressure into the aftertreatment system. The engine control module (ECM) supplies the aftertreatment fuel pressure sensor a 5 volt reference voltage. When the fuel pressure is low, the sensor signal voltage is low. When the fuel pressure is high, the sensor signal voltage is near the 5 volt reference voltage. The ECM monitors the aftertreatment fuel pressure signal circuit voltage to calculate the pressure of the fuel within the aftertreatment system.

Component LocationThe aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment fuel pressure signal voltage was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active regeneration of the aftertreatment diesel particulate filter will be disabled unitl the next key cycle.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Open return circuit in the engine harness, connector, sensorSignal wire shorted to sensor supply or battery voltageA shorted sensor.

Possible Cause:1) ECM failure2) Engine harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1926 PID: SID 332 SPN: 3480 FMI: 2 Aftertreatment Fuel Pressure Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1 – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1924 PID: SID 334 SPN: 3482 FMI: 4 Aftertreatment Fuel Shutoff Valve 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1923 PID: SID 334 SPN: 3482 FMI: 3 Aftertreatment Fuel Shutofff Valve 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1922 PID: SID 324 SPN: 3251 FMI: 0 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1921 PID: SID 324 SPN: 3251 FMI: 16 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1928 PID: SPN: 1928 FMI: 4 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment fuel pressure sensor is used to monitor the fuel pressure into the aftertreatment system. The engine control module (ECM) supplies the aftertreatment fuel pressure sensor a 5 volt reference voltage. When the fuel pressure is low, the sensor signal voltage is low. When the fuel pressure is high, the sensor signal voltage is near the 5 volt reference voltage. The ECM monitors the aftertreatment fuel pressure signal circuit voltage to calculate the pressure of the fuel within the aftertreatment system.

Component LocationThe aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment fuel pressure signal voltage was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active regeneration of the aftertreatment diesel particulate filter will be disabled unitl the next key cycle.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Open signal circuit in the engine harness, connector, sensorSignal wire shorted to groundA shorted sensor.

Possible Cause:1) ECM failure2) Engine harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1927 PID: SPN: 3480 FMI: 3 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1926 PID: SID 332 SPN: 3480 FMI: 2 Aftertreatment Fuel Pressure Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1 – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1924 PID: SID 334 SPN: 3482 FMI: 4 Aftertreatment Fuel Shutoff Valve 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1923 PID: SID 334 SPN: 3482 FMI: 3 Aftertreatment Fuel Shutofff Valve 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1922 PID: SID 324 SPN: 3251 FMI: 0 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Most Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1932 PID: SID 382 SPN: 3556 FMI: 2 Aftertreatment Doser- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionBefore active regeneration of the aftertreatment diesel particulate filter, a diagnostic test on the system is performed. The aftertreatment fuel injector opens and relieves fuel pressure in the line. The aftertreatment fuel pressure sensor must be reading atmospheric pressure at this point in the test. The aftertreatment fuel injector closes and the aftertreatment purge air actuator opens. This pressurizes the aftertreatment fuel system to vehicle air pressure. The diagnostic then checks to make sure the aftertreatment fuel pressure sensor is reading vehicle air pressure. The aftertreatment fuel shutoff valve then opens and allows pressurized fuel to enter the system. The aftertreatment fuel injector then opens and primes the system by purging the air from the line. The aftertreatment fuel shutoff valve and aftertreatment fuel injector then close and trap the fuel between the aftertreatment fuel shutoff valve and the aftertreatment fuel injector. The diagnostic checks to make sure the system maintains fuel pressure.

Component LocationThe aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the DiagnosticsThis diagnostic runs during active regeneration of the aftertreatment diesel particulate filter.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a leaking aftertreatment fuel injector or an external leak.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active regeneration of the aftertreatment diesel particulate filter will be disabled unitl the next key cycle.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and perform the INSITE™ electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A stuck open or leaking aftertreatment fuel injectorAn external leak in the aftertreatment fuel injector system.A leaking aftertreatment fuel shutoff manifold

Possible Cause:1) Aftertreatment Fuel injector failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1928 PID: SPN: 1928 FMI: 4 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1927 PID: SPN: 3480 FMI: 3 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1926 PID: SID 332 SPN: 3480 FMI: 2 Aftertreatment Fuel Pressure Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1 – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1924 PID: SID 334 SPN: 3482 FMI: 4 Aftertreatment Fuel Shutoff Valve 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1923 PID: SID 334 SPN: 3482 FMI: 3 Aftertreatment Fuel Shutofff Valve 1 Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1938 PID: SID 212 SPN: 3597 FMI: 18 ECU Power Output Supply Voltage 1- Data Valid But Below Normal Operational Range- Moderately Severe Level

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesVoltage supplied to the Variable Geometry Turbocharger (VGT) actuator dropped below 10-VDC for 10 seconds and the engine speed was at zero rpm or greater than 575 rpm.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code is logged when the voltage to the VGT actuator drops below 10-VDC. The VGT will still continue to respond to commands from the primary engine ECM.

Possible Cause:1) Battery Failure2) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1932 PID: SID 382 SPN: 3556 FMI: 2 Aftertreatment Doser- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1928 PID: SPN: 1928 FMI: 4 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1927 PID: SPN: 3480 FMI: 3 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1926 PID: SID 332 SPN: 3480 FMI: 2 Aftertreatment Fuel Pressure Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1 – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1924 PID: SID 334 SPN: 3482 FMI: 4 Aftertreatment Fuel Shutoff Valve 1 Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1942 PID: PID 101 SPN: 101 FMI: 2 Crankcase Pressure- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe crankcase pressure sensor is used to monitor the pressure inside the crankcase. The engine control module (ECM) supplies the crankcase pressure sensor a 5 volt reference voltage. When the crankcase pressure is low, the sensor signal voltage is low. When the crankcase pressure is high, the sensor signal voltage is near the 5 volt reference voltage. The ECM monitors the crankcase pressure signal circuit voltage to calculate the pressure of the air within the crankcase.

Component LocationThe crankcase pressure sensor is located near the crankcase ventilation filter.

Conditions for Running the DiagnosticsThis diagnostic consists of two parts. The first part of this diagnostic runs at initial key ON and the second part runs when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the crankcase pressure sensor was reading an erratic value at key ON or the crankcase pressure reading was not changing with engine operating conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code can be caused by a crankcase breather hose disconnected between the engine outlet and crankcase filter assembly on engines with an externally mounted crankcase filter option.

Possible causes of this fault code include:

Resistance in the wiring harnessA malfunctioning in-range pressure sensorCrankcase pressure sensor is not installed correctly in the housing.

Possible Cause:1) Crankcase breather hose2) Oil Fill cap3) Crankcase breather filter failure4) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1938 PID: SID 212 SPN: 3597 FMI: 18 ECU Power Output Supply Voltage 1- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1932 PID: SID 382 SPN: 3556 FMI: 2 Aftertreatment Doser- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1928 PID: SPN: 1928 FMI: 4 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1927 PID: SPN: 3480 FMI: 3 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1926 PID: SID 332 SPN: 3480 FMI: 2 Aftertreatment Fuel Pressure Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1 – Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1943 PID: SPN: 3555 FMI: 17 Ambient Air Density- Data Valid But Below Normal Operational Range- Least Severe Level

Circuit DescriptionThe engine control module (ECM) monitors the ambient air pressure using either an ambient air pressure sensor or a combination turbocharger compressor intake pressure/temperature sensor. These sensors respond to pressure changes in the atmosphere, which occur based on the elevation where the engine is currently operating. This pressure sensor has a 5 volt supply circuit, a sensor signal voltage, and a return circuit. The ambient air or compressor intake pressure sensor provides a signal to the ECM on the pressure sensor signal circuit. This sensor signal voltage changes based on the pressure of the atmosphere. The ECM will detect a low signal voltage when the vehicle is operating at high altitudes. The ECM will detect a high signal voltage when the vehicle is operating at sea level altitudes.

Component LocationThe barometric pressure sensor is mounted on the main branch of the engine harness near the ECM.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the barometric air pressure reading was less than a calibratible value.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Engine torque output will be limited due to the engine operating at high altitude conditions.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkWhen the engine has been operated in a high altitude location, this fault code is logged. This fault code is for information only and no repairs are necessary. The engine can possibly be derated when operating in the high altitude location to protect the turbocharger and engine from excessively high exhaust temperatures. The derate limits the torque output of the engine to keep the temperatures below the maximum temperature limits.

Note: This fault code will most likely not be active with no load in the shop. The engine must be under the same operating condition (altitude and temperature) at the time that it had originally logged.

Possible Cause:1) Barometric Pressure Sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1942 PID: PID 101 SPN: 101 FMI: 2 Crankcase Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1938 PID: SID 212 SPN: 3597 FMI: 18 ECU Power Output Supply Voltage 1- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1932 PID: SID 382 SPN: 3556 FMI: 2 Aftertreatment Doser- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1928 PID: SPN: 1928 FMI: 4 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1927 PID: SPN: 3480 FMI: 3 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1926 PID: SID 332 SPN: 3480 FMI: 2 Aftertreatment Fuel Pressure Sensor- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 195 (2 Wire) PID: PID 2559 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe coolant level sensor is a switch and is used to measure the level of the engine coolant in the radiator top tank. The coolant level sensor is immersed in the coolant and returns a different signal voltage when immersed in coolant versus being out of coolant. The engine control module (ECM) monitors the change in the signal voltage to determine the level of the engine coolant.

Component LocationThe engine coolant level sensor is typically located in the radiator top tank or surge tank. Refer to the OEM service manual for the location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the coolant level signal voltage was greater than a calibratible value for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.No engine protection will be available for low coolant level.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Open return circuit in the engine harness, connectors, or sensor.Signal circuit shorted to sensor supply or battery voltage.Sensor supply circuit shorted to battery voltage.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 187 PID: SID 211 SPN: 3510 FMI: 4 Sensor Supply 2 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 175 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 155 PID: PID 105 SPN: 105 FMI: 0 Intake Manifold 1 Temperature- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 154 PID: PID 105 SPN: 105 FMI: 4 Intake Manifold 1 Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 153 PID: PID 105 SPN: 105 FMI: 3 Intake Manifold 1 Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 151 PID: PID 110 SPN: 110 FMI: 0 Engine Coolant Temperature- Data Valid But Above Normal Operating Range- Most Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 195 (3 Wire) PID: PID 111 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe coolant level sensor is a switch and is used to measure the level of the engine coolant in the radiator top tank. The coolant level sensor is immersed in the coolant and returns a different signal voltage when immersed in coolant versus being out of coolant. The engine control module (ECM) monitors the change in the signal voltage to determine the level of the engine coolant.

Component LocationThe engine coolant level sensor is typically located in the radiator top tank or surge tank. Refer to the OEM service manual for the location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the coolant level signal voltage was greater than 4.4-VDC for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.No engine protection will be available for low coolant level.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A short circuit to battery in the OEM harnessAn open circuit in the OEM harnessA malfunctioning engine coolant level sensor

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 195 (2 Wire) PID: PID 2559 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 187 PID: SID 211 SPN: 3510 FMI: 4 Sensor Supply 2 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 175 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 155 PID: PID 105 SPN: 105 FMI: 0 Intake Manifold 1 Temperature- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 154 PID: PID 105 SPN: 105 FMI: 4 Intake Manifold 1 Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 153 PID: PID 105 SPN: 105 FMI: 3 Intake Manifold 1 Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source

Read more →

← Previous 1 … 8 9 10 11 12 … 523 Next →