CAT 3406E (Prefix 5DS or 1LW) Fault Code: 69 PID: 26 SPN: FMI: 5 Auxiliary Output #01 current low Apr 12, 2025 0 comments The ECM detects the following conditions: •There is a low current condition (open circuit) in auxiliary output 01. Probable Causes: 1) ECM Connector/harness2) Shift solenoid failure3) Shift solenoid relay4) Wiring between shift solenoid and ECM5) Gear ratios are programmed incorrectly in the ECM Share this post... Share Tweet Pin it Previous post Next post