Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 7 (CPC) Accelerator Pedal Sensor Failed High
Geplaatst door Diezel Solutions op
DESCRIPTION:Accelerator pedal sensor failed high. MONITORED PARAMETER:Pedal supply voltage. TYPICAL ENABLING CONDITIONS:Always on MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:Two seconds DASH LAMPS:CEL ENGINE REACTION:None VERIFICATION:Key Cycle: Ignition on. PROBABLE CAUSES:1. Accelerator pedal harness/connector.2. Accelerator pedal. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (CPC) Accelerator Pedal Supply Voltage Circuit Failed Low Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (ACM) Aftertreatment Control Module 2 Sensor Supply 2 Short to Ground Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (MCM) 5V Sensor Supply Bank 2 Circuit Failed Low Detroit DD13 EPA10...
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply Voltage Missing
Geplaatst door Diezel Solutions op
DESCRIPTION:Accelerator pedal sensor signal failed. MONITORED PARAMETER:Pedal supply voltage. TYPICAL ENABLING CONDITIONS:Always on MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:Two seconds DASH LAMPS:CEL ENGINE REACTION:None VERIFICATION:Key cycle: ignition on. PROBABLE CAUSES:1. Accelerator pedal harness/connector.2. Accelerator pedal. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 7 (CPC) Accelerator Pedal Sensor Failed High Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (CPC) Accelerator Pedal Supply Voltage Circuit Failed Low Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (ACM) Aftertreatment Control Module 2 Sensor Supply 2 Short to Ground Detroit DD13 EPA10 (2010-13) Fault Code:...
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
Geplaatst door Diezel Solutions op
DESCRIPTION:3V sensor supply bank 1 circuit high voltage detected. MONITORED PARAMETER:Motor Control Module (MCM) 3V internal power supply. TYPICAL ENABLING CONDITIONS:Circuit voltage greater than 3.2 Volts. MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:None VERIFICATION:Engine Idle (One minute). PROBABLE CAUSES:Short to power on one of the following from the main 120-pin ECM connector:1. Pin 29 – DOC outlet temperature sensor.2. Pin 88 – DOC inlet temperature sensor, DOC outlet temperature sensor, DPF inlet temperature sensor, DPF outlet temperature sensor. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply...
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3511 FMI 4 (MCM) 3V Sensor Supply Bank 1 Circuit Failed Low
Geplaatst door Diezel Solutions op
NOTE: Please see the step by step troubleshooting procedures for this specific code. NOTE: This code always indicates to replace the MCM. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply Voltage Missing Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 7 (CPC) Accelerator Pedal Sensor Failed High Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (CPC) Accelerator Pedal Supply Voltage Circuit Failed Low Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3510...
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3512 FMI 4 (MCM) 3V Sensor Supply Bank 2 Circuit Failed Low
Geplaatst door Diezel Solutions op
NOTE: This code indicated a motor control module (MCM) internal failure. Replace the MCM. DESCRIPTION:3V Sensor supply bank 2 circuit failed low. MONITORED PARAMETER:MCM 3V internal power supply. TYPICAL ENABLING CONDITIONS:Always enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL VERIFICATION:Engine Idle: One minute. NOTE: This code always indicates to replace the MCM. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3511 FMI 4 (MCM) 3V Sensor Supply Bank 1 Circuit Failed Low Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High Detroit DD13 EPA10 (2010-13) Fault...