Detroit Diesel– Pagina 940– ⛽ Diezel365


Detroit Diesel

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 3 (ACM) Diesel Exhaust Fluid Dosing Valve Circuit Failed High

Geplaatst door Diezel Solutions op

DESCRIPTION:Diesel Exhaust Fluid (DEF) dosing valve circuit failed high. MONITORED PARAMETER:DEF dosing valve. TYPICAL ENABLING CONDITIONS:DEF dosing valve on. MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 25% VERIFICATION:Engine Idle (1 minute). PROBABLE CAUSES:1. DEF doser valve harness connector.2. DEF metering unit failure.3. Wiring between DEF doser valve harness and the ECM. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 1 (ACM) Diesel Exhaust Fluid Pressure Duty Cycle Low Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 0 (ACM) Diesel Exhaust Fluid Pressure Duty Cycle High Detroit DD13 EPA10...

Meer lezen →


Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 4 (ACM) Diesel Exhaust Fluid Metering Valve Circuit Failed Low

Geplaatst door Diezel Solutions op

DESCRIPTION:Diesel Exhaust Fluid (DEF) metering valve circuit failed low. MONITORED PARAMETER:DEF metering valve. TYPICAL ENABLING CONDITIONS:DEF metering valve on. MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:2 Seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 25% VERIFICATION:SCR quantity test. PROBABLE CAUSES:1. DEF doser valve harness connector.2. DEF metering unit failure.3. Wiring between DEF doser valve harness and the ECM Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 3 (ACM) Diesel Exhaust Fluid Dosing Valve Circuit Failed High Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 1 (ACM) Diesel Exhaust Fluid Pressure Duty Cycle Low Detroit DD13 EPA10...

Meer lezen →


Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 5 (ACM) Diesel Exhaust Fluid Dosing Valve Circuit Failed Open

Geplaatst door Diezel Solutions op

DESCRIPTION:Diesel Exhaust Fluid (DEF) dosing valve circuit failed open. MONITORED PARAMETER:DEF dosing valve. TYPICAL ENABLING CONDITIONS:Always enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:2 seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 25% VERIFICATION:Engine Idle (1 minute). PROBABLE CAUSES:1. DEF doser valve harness connector.2. DEF metering unit failure.3. Wiring between DEF doser valve harness and the ECM. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 4 (ACM) Diesel Exhaust Fluid Metering Valve Circuit Failed Low Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 3 (ACM) Diesel Exhaust Fluid Dosing Valve Circuit Failed High Detroit DD13 EPA10 (2010-13) Fault Code:...

Meer lezen →


Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 7 (ACM) Diesel Exhaust Fluid Metering Unit – Unable to Clear Restriction

Geplaatst door Diezel Solutions op

DESCRIPTION:Diesel exhaust fluid (DEF) unit – unable to clear restriction. MONITORED PARAMETER:1. DEF pressure.2. DEF air pressure. TYPICAL ENABLING CONDITIONS:Dosing enabled MONITOR SEQUENCE:SPN 4335/14 and 31 active. EXECUTION FREQUENCY:Continuous when enabling conditions met. DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 25% VERIFICATION:Selective catalyst reduction (SCR) quantity test. PROBABLE CAUSES:1. Failed DEF pressure sensor.2. DEF metering unit air inlet restricted.3. Flush the DEF system.4. Failed diffuser heater.5. Failed DEF nozzle.6. Failed supply hose for DEF. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 5 (ACM) Diesel Exhaust Fluid Dosing Valve Circuit Failed Open Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361...

Meer lezen →


Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 8 (ACM) Diesel Exhaust Fluid Metering Unit – Exceeding Unclog Attempts

Geplaatst door Diezel Solutions op

DESCRIPTION:Diesel exhaust fluid (DEF) unit – exceeding unclog attempts. MONITORED PARAMETER:1. DEF pressure.2. DEF air pressure. TYPICAL ENABLING CONDITIONS:Dosing enabled MONITOR SEQUENCE:SPN 4335/FMI 14 and 31 active. EXECUTION FREQUENCY:Continuous when enabling conditions met. DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 25% VERIFICATION:Selective catalyst reduction (SCr) quantity test. PROBABLE CAUSES:1. Failed DEF pressure sensor.2. DEF metering unit air inlet restricted.3. Flush the DEF system.4. Failed diffuser heater.5. Failed DEF nozzle.6. Failed supply hose for DEF. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 7 (ACM) Diesel Exhaust Fluid Metering Unit – Unable to Clear Restriction Detroit DD13 EPA10 (2010-13) Fault Code:...