DESCRIPTION:EGR Delta Pressure Sensor Circuit Low.
MONITORED PARAMETER:EGR Delta Pressure Sensor.
DASH LAMPS:1. MIL2. CEL
VERIFICATION:Engine Idle: One minute.
PROBABLE CAUSES:1. EGR delta p sensor failure.2. EGR delta p connector/harness.3. EGR delta p pressure ports blocked.4. EGR valve failure.5. Inspect the EGR crossover tube and mixer pipe for excessive buildup. If excessive, replaced the EGR cooler.6. Inspect EGR system for leaks/damage/issues.
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 411 FMI 3 (MCM) Exhaust Gas Recirculation Delta P Sensor Circuit Failed High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 411 FMI 3 (MCM) EGR Delta Pressure Sensor Circuit Failed High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 411 FMI 2 (MCM) Exhaust Gas Recirculation Delta P Sensor Out of Calibration
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 411 FMI 1 (MCM) EGR Differential Pressure Failed (High Box)
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 411 FMI 0 (MCM) Exhaust Gas Recirculation Differential Pressure is Too High at Low Speeds and Loads
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 247 FMI 14 (CPC) Aftertreatment Control Module Reported Ash Mileage is Lower than the Common Powertrain Controller Stored Value