Allison WTEC II Fault Code: 63 PID: SPN: 40 FMI: Service brake status– ⛽ Diezel365


Allison WTEC II Fault Code: 63 PID: SPN: 40 FMI: Service brake status input failed on

Geplaatst door Diezel Solutions op

Subcode 40 is set when this function (Service Brake Status) is selected by calibration, and the specified input remains active for a calibration number of consecutive acceleration events. The service indicator will be turned on if it is selected by the calibration. A vehicle acceleration event is defined as an increase in transmission output speed from 1 rpm to a calibration value. The operation of the Automatic Neutral For Refuse Packer will be limited when this code is active. The active inhibit for this code is self-cleared and the service indicator will be turned off if the designated input for the Service Brake Status function becomes inactive.