Paccar– Página 205– ⛽ Diezel365


Paccar

PACCAR MX (2004 Emissions) Fault Code: P1483 EGR Valve Module – CAN Communication Error

Publicado por Diezel Solutions en

PACCAR MX (2004 Emissions) Fault Code: P1483 EGR Valve Module – CAN Communication Error SET CONDITIONS:The EGR valve module (L095) detects that the cyclic CAN command message transmitted by the PCI ECU (D420) has been missing for more than 7.5 seconds. DIAGNOSTIC CONDITION:This diagnostic runs continuously when the ignition is on. CORRESPONDING OBD READINESS MONITOR:None RESET CONDITION:This DTC changes to inactive as soon as the fault is no longer detected. REPAIR VERIFICATION:1. Clear all DTCs.2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.3. Did the DTC come back?– No, repair successful– Yes, repair unsuccessful...

Leer más →


PACCAR MX (2004 Emissions) Fault Code: P1484 EGR Valve Module – Internal Error

Publicado por Diezel Solutions en

PACCAR MX (2004 Emissions) Fault Code: P1484 EGR Valve Module – Internal Error SET CONDITIONS:The EGR valve module (L095) detects that the internal actuator current is too high. DIAGNOSTIC CONDITION:This diagnostic runs continuously when the ignition is on. CORRESPONDING OBD READINESS MONITOR:None RESET CONDITION:This DTC changes to inactive after the ignition is keyed off for at least 15 seconds and keyed on again, and the fault is no longer detected. REPAIR VERIFICATION:1. Clear all DTCs.2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.3. Did the DTC come back?– No, repair successful– Yes, repair unsuccessful...

Leer más →


PACCAR MX (2004 Emissions) Fault Code: P1485 EGR Valve Module Temperature – Data Valid but Too High

Publicado por Diezel Solutions en

PACCAR MX (2004 Emissions) Fault Code: P1485 EGR Valve Module Temperature – Data Valid but Too High SET CONDITIONS:The EGR valve module (L095) detects that the temperature of the actuator has been above 142?C for more than 30 seconds. DIAGNOSTIC CONDITION:This diagnostic runs continuously when the ignition is on. CORRESPONDING OBD READINESS MONITOR:None RESET CONDITION:This DTC changes to inactive after the ignition is keyed off for at least 15 seconds and keyed on again, and the fault is no longer detected. REPAIR VERIFICATION:1. Clear all DTCs.2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.3....

Leer más →


PACCAR MX (2004 Emissions) Fault Code: P1486 EGR Valve Module Power Supply – Incorrect

Publicado por Diezel Solutions en

PACCAR MX (2004 Emissions) Fault Code: P1486 EGR Valve Module Power Supply – Incorrect SET CONDITIONS:The EGR valve module (L095) detects that the actuator power supply is less than 7.5 V or greater than 35 V. DIAGNOSTIC CONDITION:This diagnostic runs continuously when the ignition is on. CORRESPONDING OBD READINESS MONITOR:None RESET CONDITION:This DTC changes to inactive:1. After the ignition is keyed off for at least 15 seconds and keyed on again and2. When the actuator power supply is between 8.5 V and 34 V REPAIR VERIFICATION:1. Clear all DTCs.2. Test drive or operate the vehicle to meet the diagnostic conditions...

Leer más →


PACCAR MX (2004 Emissions) Fault Code: P1487 EGR Valve Module Position – Malfunction on Sensor

Publicado por Diezel Solutions en

PACCAR MX (2004 Emissions) Fault Code: P1487 EGR Valve Module Position – Malfunction on Sensor SET CONDITIONS:The EGR valve module (L095) detects a failure or deviation on the internal shaft position sensor. DIAGNOSTIC CONDITION:This diagnostic runs continuously when the ignition is on. CORRESPONDING OBD READINESS MONITOR:None RESET CONDITION:This DTC changes to inactive after the ignition is keyed off for at least 15 seconds and keyed on again and the error is no longer detected. REPAIR VERIFICATION:1. Clear all DTCs.2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.3. Did the DTC come back?– No, repair...

Leer más →