Ir directamente al contenido

Telegram : @Diezel365

Eaton Gen 2 (AutoShift) Fault Code: 81 PID: SID 47 FMI: 7 Gear Engagement Detected

Overview:
The Transmission Controller detected that the Shift Finger position indicates neutral and a comparison of Input and Main Shaft speeds indicate the transmission is in gear. The comparison of shaft speeds is only performed when the vehicle is moving and a shift is in process. This fault can only be set during a shift, and becomes inactive after power
down.

Detection:
The fault is detected after the Transmission Controller powers up and a non-neutral condition is detected during a shift.

Fallback:
This fault causes an in-place fallback. The transmission will remain in current gear.

Possible Causes:
1) Worn internal transmission components

Eaton Gen 2 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 12 Failed to Synchronize
Eaton Gen 2 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 10 Failed to Synchronize
Eaton Gen 2 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 7 Failed to Synchronize
Eaton Gen 2 (AutoShift) Fault Code: 73 PID: SID 58 FMI: 7 Failed to Engage Gear
Eaton Gen 2 (AutoShift) Fault Code: 72 PID: SID 59 FMI: 7 Failed to Select Rail
Eaton Gen 2 (AutoShift) Fault Code: 71 PID: SID 60 FMI: 7 Stuck Engaged