Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 0 (ACM) Diesel Exhaust Fluid Tank Temperature – High
Publicado por Diezel Solutions en
DESCRIPTION:Diesel exhaust fluid (DEF) tank temperature – high. MONITORED PARAMETER:DEF tank temperature. TYPICAL ENABLING CONDITIONS:1. Coolant valve closed greater than 1.5 hrs.2. Coolant temperature greater than 158°F. MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:Five seconds DASH LAMPS:MIL VERIFICATION:Parked regeneration NOTE: If codes 3363-3, 3363-4, or 3363-5 active, fix those first. PROBABLE CAUSES:1. Coolant line from engine to DEF pump.2. DEF tank header assy.3. DEF tank header assy harness/connector. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI 8 (ACM) Diesel Exhaust Fluid Metering Unit – Exceeding Unclog Attempts Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3361 FMI...
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 1 (ACM) Diesel Exhaust Fluid Tank Temperature – Low
Publicado por Diezel Solutions en
NOTE: This code sets when the diesel exhaust fluid (DEF) tank temperature does not increase 0.5°C (0.9°F) within 300 seconds after the DEF tank coolant valve has bn commanded on. DESCRIPTION:DEF tank temperature – low. MONITORED PARAMETER:DEF tank temperature. TYPICAL ENABLING CONDITIONS:1. Coolant valve commanded open.2. Coolant temperature greater than 70°C (158°F).3. Ambient temperature less than -1°C (30°F) as measured by the ACM. MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:30 minutes DASH LAMPS:MIL VERIFICATION:Parked regeneration NOTE: If any cooling system codes present, fix this first. NOTE: If codes 3363-3, 3363-4, or 3363-5 active, fix those first. PROBABLE...
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 3 (ACM) Diesel Exhaust Fluid Coolant Valve Circuit Failed High
Publicado por Diezel Solutions en
DESCRIPTION:Diesel exhaust fluid (DEF) coolant valve circuit failed high. MONITORED PARAMETER:DEF coolant valve. TYPICAL ENABLING CONDITIONS:DEF tank temperature less than 36°F and engine coolant temperature greater than 32°F. MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 10% VERIFICATION:Output component test. NOTE: If code not active, release vehicle to customer. PROBABLE CAUSES:1. DEF coolant valve harness connector.2. Wiring between DEF coolant valve harness connector and the 120-pin ECM connection. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 1 (ACM) Diesel Exhaust Fluid Tank Temperature – Low Detroit DD13 EPA10 (2010-13) Fault...
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 4 (ACM) Diesel Exhaust Fluid Valve Circuit Failed Low
Publicado por Diezel Solutions en
DESCRIPTION:Diesel exhaust fluid (DEF) valve circuit failed low. MONITORED PARAMETER:DEF valve TYPICAL ENABLING CONDITIONS:DEF tank temperature less than 36°F and engine valve temperature greater than 32°F. MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 10% VERIFICATION:Output component test. PROBABLE CAUSES:1. DEF valve connector harness.2. Wiring between DEF valve connector and the 120-pin ECM. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 3 (ACM) Diesel Exhaust Fluid Coolant Valve Circuit Failed High Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 1 (ACM) Diesel Exhaust Fluid Tank Temperature – Low Detroit...
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 5 (ACM) Diesel Exhaust Fluid Coolant Valve Circuit Failed Open
Publicado por Diezel Solutions en
DESCRIPTION:Diesel exhaust fluid (DEF) coolant valve circuit failed open. MONITORED PARAMETER:DEF coolant valve. TYPICAL ENABLING CONDITIONS:Always enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:Derate 10% VERIFICATION:Engine Idle: One minute. NOTE: If code not active, release vehicle to customer. PROBABLE CAUSES:1. DEF coolant valve harness connector.2. Wiring between DEF coolant valve harness connector and the 120-pin ECM connection. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 4 (ACM) Diesel Exhaust Fluid Valve Circuit Failed Low Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 3 (ACM) Diesel Exhaust Fluid Coolant Valve Circuit Failed...