Detroit Diesel
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3511 FMI 4 (CPC) Remote Accelerator Pedal Supply Voltage Circuit Failed Low
Publicado por Diezel Solutions en
NOTE: This code sets when the common powertrain controller (CPC) detects the voltage on the sensor supply circuits is out of range. DESCRIPTION:Remote accelerator pedal supply voltage circuit failed low. MONITORED PARAMETER:Remote accelerator pedal voltage. TYPICAL ENABLING CONDITIONS:Always on MONITOR SEQUENCE:Key on EXECUTION FREQUENCY:None TYPICAL DURATION:None DASH LAMPS:CEL ENGINE REACTION:Idle only VERIFICATION:1. Ignition key2. Cycle on POSSIBLE CAUSES:1. Remote accelerator pedal assembly.2. Circuit fault.3. Fault within the CPC.4. Improper configuration of the CPC. NOTE: This code always indicates to replace the MCM. Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed...
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3511 FMI 4 (MCM) 3V Sensor Supply Bank 1 Circuit Failed Low
Publicado por Diezel Solutions en
NOTE: Please see the step by step troubleshooting procedures for this specific code. NOTE: This code always indicates to replace the MCM. Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3511 FMI 4 (CPC) Remote Accelerator Pedal Supply Voltage Circuit Failed Low Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3511 FMI 3 (CPC) Remote Accelerator Pedal Supply Voltage Circuit Failed High Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply Voltage Missing Detroit DD16 GHG14 (2014-16)...
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3512 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
Publicado por Diezel Solutions en
NOTE: This fault indicates that the motor control module (MCM) detects a short to power (voltage greater than 3.2. on any of the MCM pins). PROBABLE CAUSES:Short to power on one of the following from the main 120-pin ECM connector:1. Pin 55 – Fuel temp sensor, engine coolant temp sensor.2. Pin 77 – Fuel temp sensor.3. Pin 102 – Charge air cooler outlet pressure sensor.4. Pin 108 – Engine oil temperature/pressure sensor.5. Pin 110 – Engine coolant temperature sensor. Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3511 FMI 4 (MCM) 3V Sensor Supply Bank 1 Circuit Failed Low Detroit DD16...
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3512 FMI 4 (MCM) 3V Sensor Supply Bank 2 Circuit Failed Low
Publicado por Diezel Solutions en
NOTE: This code indicated a motor control module (MCM) internal failure. Replace the MCM. DESCRIPTION:3V Sensor supply bank 2 circuit failed low. MONITORED PARAMETER:MCM 3V internal power supply. TYPICAL ENABLING CONDITIONS:Always enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Always enabled TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL VERIFICATION:Engine Idle: One minute. NOTE: This code always indicates to replace the MCM. Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3512 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3511 FMI 4 (MCM) 3V Sensor Supply Bank 1 Circuit Failed Low Detroit DD16 GHG14 (2014-16) Fault...
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3517 FMI 19 (ACM) Diesel Exhaust Fluid Tank Signal Erratic via CAN
Publicado por Diezel Solutions en
NOTE: Please see the step by step troubleshooting procedures for this specific code. NOTE: If the ACM (Computer module) has been programmed recently, clear code, test drive, and if code doesn’t come back releaes the vehicle. PROBABLE CAUSES:1. Check DEF tank header harness connector/wiring.2. DEF CAN harness.3. Failed DEF tank header. Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3517 FMI 9 (ACM) Diesel Exhaust Fluid Tank Signal Not Available via CAN Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3512 FMI 4 (MCM) 3V Sensor Supply Bank 2 Circuit Failed Low Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3512 FMI 3...