Ir directamente al contenido

Telegram : @Diezel365

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4752 FMI 0 (MCM) Exhaust Gas Recirculation Cooler Low Efficiency

DESCRIPTION:
Exhaust Gas Recirculation (EGR) cooler low efficiency.

MONITORED PARAMETER:
Intake manifold and charge air cooler outlet temperature sensors.

TYPICAL ENABLING CONDITIONS:
1. Coolant temperature greater than 70°C (158°F)
2. Engine running greater than 5 minutes.

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
10

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
Derate 10%

VERIFICATION:
1. Start engine.
2. Warm up such that coolant temperature greater than 70°C (158°F).
3. Run engine greater than 5 minutes.

NOTE: If there are any cooling system related issues, fix those first.

PROBABLE CAUSES:
1. Intake manifold air temperature sensor.
2. Intake manifold air temperature sensor connector/harness.
3. EGR system leaks (Look for soot).
4. Remove the EGR hot pipe, EGR crossover tube, and mixer pipe. If blockage found, replace the EGR Cooler.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4375 FMI 6 (ACM) Diesel Exhaust Fluid Pump Supply Current High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4375 FMI 5 (ACM) Diesel Exhaust Fluid Pump Circuit Failed Open
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4375 FMI 4 (ACM) Diesel Exhaust Fluid Pump Circuit Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4375 FMI 3 (ACM) Diesel Exhaust Fluid Pump Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4364 FMI 18 (ACM) Selective Catalyst Reduction NOx Conversion Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4364 FMI 1 (ACM) Selective Catalyst Reduction NOx Conversion Very Low