DESCRIPTION:
Intake manifold pressure circuit failed low.
MONITORED PARAMETER:
Intake manifold pressure circuit.
TYPICAL ENABLING CONDITIONS:
Always on
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 25%
VERIFICATION:
Parked regeneration
PROBABLE CAUSES:
1. Failed inlet manifold pressure sensor.
2. Inlet manifold pressure sensor connector/harness
3. Charge air cooler failure.
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3563 FMI 3 (MCM) Intake Manifold Pressure Circuit Failed High
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3556 FMI 1 (MCM) Check for Regeneration Temperature Out of Range Low
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3512 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply Voltage Missing
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3510 FMI 7 (CPC) Accelerator Pedal Sensor Failed High