DESCRIPTION:Quantity control valve (High Side) error.
MONITORED PARAMETER:Quantity control valve.
TYPICAL ENABLING CONDITIONS:Always enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Continuous when enabling conditions met.
TYPICAL DURATION:Two seconds
DASH LAMPS:1. MIL2. CEL
ENGINE REACTION:Derate 25%
VERIFICATION:Engine idle: One minute.
POSSIBLE CAUSES:1. MCM pin 1 circuit is shorted to ground.2. Internal short of the quantity control valve.
NOTE: If code 5418-4 is also active, repair 5418-4 first.
PROBABLE CAUSES:1. Quantity control valve harness connector/wiring.2. Failed quantity control valve.