DESCRIPTION:Diesel exhaust fluid (DEF) pressure limiting unit circuit failed low.
MONITORED PARAMETER:Diesel exhaust fluid (DEF) pressure limiting unit.
TYPICAL ENABLING CONDITIONS:Diesel exhaust fluid (DEF) pressure limiting unit on.
EXECUTION FREQUENCY:Continuous when enabling conditions met.
DASH LAMPS:1. MIL2. CEL
VERIFICATION:Output component test.
NOTE: If code is inactive, disregard.
NOTE: Otherwise, check the DEF pressure limiting unit harness connector and wiring. If no problems found, replace the pressure limiting unit.