DESCRIPTION:Motor Control Module (MCM) internal injector power supply failed high.
MONITORED PARAMETER:MCM internal injector power supply.
TYPICAL ENABLING CONDITIONS:Always enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Always Enabled
TYPICAL DURATION:2 Second
DASH LAMPS:1. MIL2. CEL
ENGINE REACTION:Derate 25%
VERIFICATION:Engine Idle (1 minute).
PROBABLE CAUSES:1. Doser heater.2. Doser heater lines 1, 2, 3, or 4.3. ACM (Aftertreatment Control Module) failure.4. Short to battery between ACM pins 9, 15, 39, or 2 and their components.5. Reconnect items in #4 one at a time and clear the fault code after each connection. When fault becomes active, replace the components.