DESCRIPTION:Engine oil temperature sensor plausibility fault.
MONITORED PARAMETER:Coolant outlet and oil temperature sensors.
TYPICAL ENABLING CONDITIONS:Engine running greater than 1200s.
VERIFICATION:Run engine greater than 1200s.
PROBABLE CAUSES:1. Oil temperature sensor.2. Oil temperature sensor connector/harness.3. Low engine oil level.
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 175 FMI 4 (MCM) Engine Oil Temperature Circuit Failed Low
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 175 FMI 3 (MCM) Engine Oil Temperature Circuit Failed High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 175 FMI 0 (MCM) Oil Temperature High Warning
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 174 FMI 4 (MCM) Supply Fuel Temperature Sensor Short Circuit to Ground
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 174 FMI 3 (MCM) Supply Fuel Temperature Sensor Open Circuit
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 174 FMI 2 (MCM) Fuel Temperature Sensor, General Temperature Plausibility