DESCRIPTION:Hydrocarbon (HC) doser fuel line pressure (FLP) sensors-failed self test.
MONITORED PARAMETER:Doser fuel line pressure.
TYPICAL ENABLING CONDITIONS:Dosing enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Continuous when enabling conditions met.
TYPICAL DURATION:One minute
DASH LAMPS:1. MIL2. CEL
ENGINE REACTION:Derate 10%
VERIFICATION:Parked regeneration
PROBABLE CAUSES:1. Replace the fuel compensation pressure sensor.2. Perform stationary regen.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 4 (MCM) Fuel Compensation Pressure Sensor Circuit Failed Low
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 3 (MCM) Fuel Compensation Pressure Sensor Circuit Failed High
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 2 (MCM) Hydrocarbon Doser Fuel Line Pressure Low
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 1 (MCM) Hydrocarbon Doser Fuel Supply Pressure Abnormal
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 0 (MCM) Fuel Compensation Pressure High
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3471 FMI 5 (MCM) Hydrocarbon Doser Circuit Failed Open