Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1691 PID: SID 380 SPN: 5298 FMI: 18 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel oxidation catalyst is located in the exhaust system. The location of the catalyst can vary, depending on the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running and active regeneration of the aftertreatment diesel particulate filter is occurring.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) calculated the DOC efficiency was less than required to successfully complete a regeneration.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and perform the INSITE™ electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning diesel oxidation catalystA malfunctioning aftertreatment fuel injector

Possible Cause:1) Aftertreatment fuel injector2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1686 PID: SPN: 3364 FMI: 3 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1685 PID: SPN: 3364 FMI: 4 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1684 PID: SPN: 3363 FMI: 4 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1683 PID: SPN: 3363 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1682 PID: SPN: 3362 FMI: 31 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (Multiplexed) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1694 PID: PID 2201 SPN: 3226 FMI: 2 Aftertreatment 1 Outlet Nox Sensor- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor reading was not changing with engine conditions or is stuck.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.To validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Diesel exhaust fluid crystallization or depositsIncorrectly installed aftertreatment outlet NOx sensorMalfunctioning aftertreatment outlet NOx sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

This diagnostic will NOT run during a regeneration.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) N/A

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1691 PID: SID 380 SPN: 5298 FMI: 18 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1686 PID: SPN: 3364 FMI: 3 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1685 PID: SPN: 3364 FMI: 4 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1684 PID: SPN: 3363 FMI: 4 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1683 PID: SPN: 3363 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1682 PID: SPN: 3362 FMI: 31 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines- Condition Exists

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1695 PID: SID 232 SPN: 3513 FMI: 3 Sensor Supply 5- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe sensor supply 5 circuit of the engine control module (ECM) provides a 5 volt supply for the aftertreatment diesel particulate filter differential pressure sensor, remote accelerator, engine coolant level sensor, fan speed sensor, and the accelerator position sensor 2.

Component LocationSensor Supply 5 is dedicated for the secondary accelerator pedal position sensor in the OEM wiring harness. Sensor supply 5 can also be used for other sensors in the OEM wiring harness.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the sensor supply 5 signal voltage was greater than 5.25-VDC for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The engine will have limp-home throttle control only.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkHigh voltage on the 5-VDC supply wire can be caused by a short circuit to a power supply, a damaged sensor, or a damaged ECM power supply.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1694 PID: PID 2201 SPN: 3226 FMI: 2 Aftertreatment 1 Outlet Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1691 PID: SID 380 SPN: 5298 FMI: 18 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1686 PID: SPN: 3364 FMI: 3 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1685 PID: SPN: 3364 FMI: 4 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1684 PID: SPN: 3363 FMI: 4 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1683 PID: SPN: 3363 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1696 PID: SID 232 SPN: 3513 FMI: 4 Sensor Supply 5- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe sensor supply 5 circuit of the engine control module (ECM) provides a 5 volt supply for the aftertreatment diesel particulate filter differential pressure sensor, remote accelerator, engine coolant level sensor, fan speed sensor, and the accelerator position sensor 2.

Component LocationSensor Supply 5 is dedicated for the secondary accelerator pedal position sensor in the OEM wiring harness. Sensor supply 5 can also be used for other sensors in the OEM wiring harness.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the sensor supply 5 signal voltage was less than 4.75-VDC for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The engine will have limp-home throttle control only.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkLow voltage on the 5 volt supply wire can be caused by a short circuit to ground in a supply wire, a short circuit between a supply wire and a return wire, a damaged sensor, or a damaged ECM power supply.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Accelerator/lever position sensor failure2) Aftertreatment Diesel particulate filter differential pressure sensor failure3) Engine coolant level sensor failure4) Remote Accelerator pedal/lever failure5) Fan speed sensor failure6) Aftertreatment DEF dosing unit failure7) OEM harness8) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1695 PID: SID 232 SPN: 3513 FMI: 3 Sensor Supply 5- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1694 PID: PID 2201 SPN: 3226 FMI: 2 Aftertreatment 1 Outlet Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1691 PID: SID 380 SPN: 5298 FMI: 18 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1686 PID: SPN: 3364 FMI: 3 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1685 PID: SPN: 3364 FMI: 4 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1684 PID: SPN: 3363 FMI: 4 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1712 PID: SPN: 3363 FMI: 18 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank heater keeps the diesel exhaust fluid from freezing in the diesel exhaust fluid tank. The tank heater consists of an electrically powered tank heater control valve which controls the flow of engine coolant to a heating coil inside the diesel exhaust fluid tank. The tank heater control valve opens to allow coolant to flow to the heating coil when heating is commanded, and closes when heating is no longer required.

Component LocationThe diesel exhaust fluid tank heater control valve is located near the diesel exhaust fluid tank. Specific location will vary depending on the vehicle OEM. The tank heating coil is internal to the diesel exhaust fluid tank.

Conditions for Running the DiagnosticsThis diagnostic runs a calibrated amount of time after diesel exhaust fluid tank heating is first commanded.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature failed to thaw after the aftertreatment diesel exhaust fluid tank heater was commanded on for a calibratable time.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeThe fault code status in INSITE™ electronic service tool will change to INACTIVE immediately after the system is able to adequately heat and the diagnostic runs and passes. If heating can not be completed, use the “Diesel Exhaust Fluid Doser System Heater Test” found under “ECM Diagnostic Test” in INSITE™ electronic service tool to command heating to the tank heater and all line heaters.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Aftertreatment diesel exhaust fluid tank heater control valve stuck closedBlockage or restrictons in the coolant plumbing to the diesel exhaust fluid tank heaterEngine coolant level lowMalfunctioning aftertreatment diesel exhaust fluid tank heater control valveReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Coolant Level2) DEF tank heater control valve failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1696 PID: SID 232 SPN: 3513 FMI: 4 Sensor Supply 5- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1695 PID: SID 232 SPN: 3513 FMI: 3 Sensor Supply 5- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1694 PID: PID 2201 SPN: 3226 FMI: 2 Aftertreatment 1 Outlet Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1691 PID: SID 380 SPN: 5298 FMI: 18 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1686 PID: SPN: 3364 FMI: 3 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1685 PID: SPN: 3364 FMI: 4 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1713 PID: SPN: 3363 FMI: 16 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank heater keeps the diesel exhaust fluid from freezing in the diesel exhaust fluid tank. The tank heater consists of an electrically powered tank heater control valve which controls the flow of engine coolant to a heating coil inside the diesel exhaust fluid tank. The tank heater control valve opens to allow coolant to flow to the heating coil when heating is commanded, and closes when heating is no longer required.

Component LocationThe diesel exhaust fluid tank heater control valve is located near the diesel exhaust fluid tank. Specific location will vary depending on the vehicle OEM. The tank heating coil is internal to the diesel exhaust fluid tank.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when diesel exhaust fluid tank heating is NOT being commanded.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the DEF tank temperature was greater than 75°C [170°F] indicating the aftertreatment diesel exhaust fluid tank heater was in the ON position when the ECM was commanding the heater to be in the OFF position.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkBefore troubleshooting this fault code, make sure the vehicle is not equipped with an auxiliary heating device for the diesel exhaust fluid tank. Such a device can result in overheating the diesel exhaust fluid in the tank.

This fault code may be inactive when the vehicle is brought in for service. Even if inactive, follow the troubleshooting tree completely.

Reason: If there is a problem with the diesel exhaust fluid (DEF) tank heater control valve, the valve is stuck open, there is coolant leaking past the valve seat, or the valve is incorrectly installed, it can take long periods of operation at high load before the tank temperature gradually increases to the fault code threshold value of 77°C [170°F]. As soon as the temperature drops below 75°C [167°F] due to a stopped engine, overnight parking, reduced coolant temperature, and so forth, the fault code will go inactive while the root cause of the issue is still present.Possible causes of this fault code include:

Aftertreatment diesel exhaust fluid tank heater control valve installed incorrectly, reversed relative to coolant flow direction.Malfunctioning aftertreatment diesel exhaust fluid tank heater control valve – stuck open or leakage past the valve seat.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) DEF tank temperature sensor failure2) DEF tank heater control valve failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1712 PID: SPN: 3363 FMI: 18 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1696 PID: SID 232 SPN: 3513 FMI: 4 Sensor Supply 5- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1695 PID: SID 232 SPN: 3513 FMI: 3 Sensor Supply 5- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1694 PID: PID 2201 SPN: 3226 FMI: 2 Aftertreatment 1 Outlet Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1691 PID: SID 380 SPN: 5298 FMI: 18 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1686 PID: SPN: 3364 FMI: 3 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1715 PID: SPN: 3364 FMI: 11 Aftertreatment Diesel Exhaust Fluid Quality- Root Cause Not Known

Circuit DescriptionThe aftertreatment diesel exhaust fluid quality sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor is used to measure the concentration of the aftertreatment diesel exhaust fluid in the tank.

Component LocationThe aftertreatment diesel exhaust fluid quality sensor is located in the aftertreatment diesel exhaust fluid tank. It may be a combination sensor with the aftertreatement diesel exhaust fluid tank level and tank temperature sensors. Location of the tank and sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe DEF quality sensor has reported an internal error.

Action Taken When the Fault Code is ActiveThe ECM will illuminate the amber CHECK ENGINE light immediately when the diagnostic runs and fails.

Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.

Shop TalkPossible caused of this fault code include:

Malfunctioning Aftertreatment DEF Quality Sensor.

Possible Cause:1) Aftertreatment DEF quality sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1713 PID: SPN: 3363 FMI: 16 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1712 PID: SPN: 3363 FMI: 18 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1696 PID: SID 232 SPN: 3513 FMI: 4 Sensor Supply 5- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1695 PID: SID 232 SPN: 3513 FMI: 3 Sensor Supply 5- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1694 PID: PID 2201 SPN: 3226 FMI: 2 Aftertreatment 1 Outlet Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1691 PID: SID 380 SPN: 5298 FMI: 18 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1718 PID: SPN: 1322 FMI: 31 Engine Misfire for Multiple Cylinders- Condition Exists

Circuit DescriptionAn algorithm in the ECM calibration monitors engine speed as each injector fires. If a cylinder(s) has high or low contribution to engine speed, the fault will become active. The intention of the fault is to assist in troubleshooting performance complaints such as engine misfire and low power.

Component LocationThe ECM mounting location varies, depending on the engine model, and may be mounted either on or off the engine.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a misfire of two or more cylinders.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf Fault Code 1718 is inactive in the ECM memory and there is no complaint such as “low power” or “engine misfire”, it is possible that an intermittent event such as air entering the fuel system following a filter change caused the fault. Inactive counts of Fault Code 1718 should be disregarded unless other performance symptoms are present. The engine coolant temperature must be greater than 71°C [160°F] before this diagnostic will run.

Causes of cylinder misfire can include:

Valve lash out of specification (compare actual valve lash to reset limits)Cylinder damaged (check for high blowby when the engine is loaded)Valve damaged or valve held open (listen for intake valve “chirping” noise in the intake)Injector malfunction (“swap” injectors to see if the problem “follows” the indicated injector).

Possible Cause:1) Cylinder Misfire2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1715 PID: SPN: 3364 FMI: 11 Aftertreatment Diesel Exhaust Fluid Quality- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1713 PID: SPN: 3363 FMI: 16 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1712 PID: SPN: 3363 FMI: 18 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1696 PID: SID 232 SPN: 3513 FMI: 4 Sensor Supply 5- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1695 PID: SID 232 SPN: 3513 FMI: 3 Sensor Supply 5- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1694 PID: PID 2201 SPN: 3226 FMI: 2 Aftertreatment 1 Outlet Nox Sensor- Data Erratic, Intermittent, or Incorrect

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 175 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe engine control module (ECM) controls the engine intake air throttle actuator. The ECM can open and close the throttle based on the operating condtions in order to regulate air flow to the engine.

Component LocationThe engine intake air throttle actuator is mounted in the piping between the charge air cooler and intake manifold.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine intake air throttle actuator signal is shorted to voltage when the actuator is commanded OFF.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.

Engine intake air throttle actuation will be disabled. The engine intake air throttle will default to the open position.

Exhaust Gas Recirculation (EGR) valve operation will be disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

An open or short circuit to battery in the engine harness.A malfunctioning engine intake air throttle actuator

Possible Cause:1) Intake throttle Actuator assembly failure2) Engine harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 155 PID: PID 105 SPN: 105 FMI: 0 Intake Manifold 1 Temperature- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 154 PID: PID 105 SPN: 105 FMI: 4 Intake Manifold 1 Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 153 PID: PID 105 SPN: 105 FMI: 3 Intake Manifold 1 Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 151 PID: PID 110 SPN: 110 FMI: 0 Engine Coolant Temperature- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 146 PID: PID 110 SPN: 110 FMI: 16 Engine Coolant Temperature- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 145 PID: PID 110 SPN: 110 FMI: 4 Engine Coolant Temperature 1 Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1843 PID: PID 101 SPN: 101 FMI: 3 Crankcase Pressure Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe crankcase pressure sensor is used to monitor the pressure inside the crankcase. The engine control module (ECM) supplies the crankcase pressure sensor a 5 volt reference voltage. When the crankcase pressure is low, the sensor signal voltage is low. When the crankcase pressure is high, the sensor signal voltage is near the 5 volt reference voltage. The ECM monitors the crankcase pressure signal circuit voltage to calculate the pressure of the air within the crankcase.

Component LocationThe crankcase pressure sensor is located near the crankcase ventilation filter.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the crankcase pressure signal voltage was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the crankcase pressure reading is used.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe crankcase pressure sensor shares supply and return wires in the engine harness with other sensors. Opens and shorts in the engine harness can cause multiple fault codes to be active. Before troubleshooting, check for multiple fault codes.

Possible causes of this fault code include:

Open return circuit in the engine harness, connectors, or sensorSignal wire shorted to sensor supply or battery voltage.

Possible Cause:1) ECM failure2) Engine harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1718 PID: SPN: 1322 FMI: 31 Engine Misfire for Multiple Cylinders- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1715 PID: SPN: 3364 FMI: 11 Aftertreatment Diesel Exhaust Fluid Quality- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1713 PID: SPN: 3363 FMI: 16 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1712 PID: SPN: 3363 FMI: 18 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1696 PID: SID 232 SPN: 3513 FMI: 4 Sensor Supply 5- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1695 PID: SID 232 SPN: 3513 FMI: 3 Sensor Supply 5- Voltage Above Normal or Shorted to High Source

Leer más →