Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6812 PID: SPN: 3515 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted High

Lamp:None

Reason:An offset in the diesel exhaust fluid quality sensor temperature reading has been detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment diesel exhaust fluid quality sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor is used to measure the concentration of the aftertreatment diesel exhaust fluid in the tank.

Component Location:The DEF quality sensor is typically mounted in the DEF tank or in-line with the DEF dosing unit supply line.

Conditions for Running the Diagnostics:The engine must be turned OFF for period of 8 hours before this diagnostic will run. This diagnostic runs when the keyswitch is turned to the ON position after an 8 hour cold soak.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature sensor reading was higher or lower than the other temperature sensors on the engine.

Action Taken When the Fault Code is Active:The ECM logs the fault code immediately when the diagnostic runs and fails.

Conditions for Clearing the Fault Code:1. To validate the repair, the engine must be shut down with the keyswitch in the OFF position for 8 hours. After the 8 hour cold soak, start the engine and let it idle for 1 minute.2. The fault code status displayed by the diagnostic tool will change to inactive immediately after the diagnostic runs and passes.3. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults.

Shop Talk:Possible causes of this fault code include:Malfunctioning aftertreatment DEF quality sensor.

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6811 PID: SPN: 4334 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6799 PID: SPN: 4334 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6798 PID: SPN: 3031 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6797 PID: SPN: 3031 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6794 PID: SPN: 7854 FMI: 2/21 Aftertreatment 1 Particulate Sensor Module – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6793 PID: SPN: 7854 FMI: 2/20 Aftertreatment 1 Particulate Sensor Module – Data Not Rational – Drifted High

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6813 PID: SPN: 3515 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted Low

Lamp:None

Reason:An offset in the diesel exhaust fluid quality sensor temperature reading has been detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment diesel exhaust fluid quality sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor is used to measure the concentration of the aftertreatment diesel exhaust fluid in the tank.

Component Location:The DEF quality sensor is typically mounted in the DEF tank or in-line with the DEF dosing unit supply line.

Conditions for Running the Diagnostics:The engine must be turned OFF for period of 8 hours before this diagnostic will run. This diagnostic runs when the keyswitch is turned to the ON position after an 8 hour cold soak.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature sensor reading was higher or lower than the other temperature sensors on the engine.

Action Taken When the Fault Code is Active:The ECM logs the fault code immediately when the diagnostic runs and fails.

Conditions for Clearing the Fault Code:1. To validate the repair, the engine must be shut down with the keyswitch in the OFF position for 8 hours. After the 8 hour cold soak, start the engine and let it idle for 1 minute.2. The fault code status displayed by the diagnostic tool will change to inactive immediately after the diagnostic runs and passes.3. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults.

Shop Talk:Possible causes of this fault code include:Malfunctioning aftertreatment DEF quality sensor.

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6812 PID: SPN: 3515 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6811 PID: SPN: 4334 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6799 PID: SPN: 4334 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6798 PID: SPN: 3031 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6797 PID: SPN: 3031 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6794 PID: SPN: 7854 FMI: 2/21 Aftertreatment 1 Particulate Sensor Module – Data Not Rational – Drifted Low

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6814 PID: SPN: 3227 FMI: 2/20 Aftertreatment 1 Outlet Oxygen Sensor – Data Not Rational – Drifted High

Lamp:None

Reason:An offset in the outlet NOx sensor oxygen reading has been detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment outlet NOx (Nitrogen Oxides) sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component Location:The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the Diagnostics:This diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor reading was not changing with engine conditions or is stuck.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair, start and operate the engine to raise exhaust temperatures.2. To validate the repair using a chassis dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.3. To validate the repair using a diagnostic road test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.4. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Diesel exhaust fluid crystallization or deposits.2. Incorrectly installed aftertreatment outlet NOx sensor.3. Malfunctioning aftertreatment outlet NOx sensor.4. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.5. This diagnostic will NOT run during a regeneration.6. For intermittent power supply and datalink communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6813 PID: SPN: 3515 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6812 PID: SPN: 3515 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6811 PID: SPN: 4334 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6799 PID: SPN: 4334 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6798 PID: SPN: 3031 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6797 PID: SPN: 3031 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Data Not Rational – Drifted High

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6815 PID: SPN: 3227 FMI: 2/21 Aftertreatment 1 Outlet Oxygen Sensor – Data Not Rational – Drifted Low

Lamp:None

Reason:An offset in the outlet NOx sensor oxygen reading has been detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component Location:The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the Selective Catalytic Reduction (SCR) catalyst.

Conditions for Running the Diagnostics:This diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor reading was not changing with engine conditions or is stuck.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair, start and operate the engine to raise exhaust temperatures.2. To validate the repair using a chassis dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.3. To validate the repair using a diagnostic road test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.4. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Diesel exhaust fluid crystallization or deposits.2. Incorrectly installed aftertreatment outlet NOx sensor.3. Malfunctioning aftertreatment outlet NOx sensor.4. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.5. This diagnostic will NOT run during a regeneration.6. For intermittent power supply and datalink communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6814 PID: SPN: 3227 FMI: 2/20 Aftertreatment 1 Outlet Oxygen Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6813 PID: SPN: 3515 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6812 PID: SPN: 3515 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6811 PID: SPN: 4334 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6799 PID: SPN: 4334 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6798 PID: SPN: 3031 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Data Not Rational – Drifted Low

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 687 PID: PID 103 SPN: 103 FMI: 18 Turbocharger 1 Speed- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe turbocharger speed sensor is a variable reluctance speed sensor. It consists of a coil of wire and an iron core. The target on the turbocharger shaft is a ground flat in the center of the shaft. As the flat on the turbocharger shaft spins past the speed sensor, a signal is generated. The Engine Control Module (ECM) interprets this signal and converts it to a turbocharger speed reading.

Component LocationThe turbocharger speed sensor is mounted in the center housing of the turbocharger.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the turbocharger speed was less than 600 rpm for more than 1 second when the engine speed was greater than 1200 rpm.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The ECM will estimate the turbocharger speed.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkItems that can cause this fault code include:

Damaged turbocharger speed sensorDamaged engine harnessDamaged ECM.Operating the engine at idle or high idle while stationary will not create enough load to maintain boost pressure at 1.19 times ambient pressure for 30 consecutive seconds. .

Although it is possible for a damaged ECM to be the root cause of this fault code, it is highly unlikely. ECM replacement should only be considered as a last resort, if no other repairs are successful in clearing the fault code.

In very rare cases, it has been shown that the turbocharger can cause this fault code to come active and turbocharger replacement may be the only way to clear the fault code.

Possible Cause:1) Turbocharger speed sensor failure2) Engine harness, or Connector(s)3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 649 PID: SID 115 SPN: 1378 FMI: 31 Engine Oil Change Interval- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 629 PID: PID 314 SPN: 1176 FMI: 18 Turbocharger 1 Compressor Inlet Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 597 PID: PID 167 SPN: 167 FMI: 18 Electrical Charging System Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 596 PID: PID 167 SPN: 167 FMI: 16 Electrical Charging System Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 595 PID: PID 103 SPN: 103 FMI: 16 Turbocharger 1 Speed- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 585 PID: SID 39 SPN: 677 FMI: 4 Starter Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 689 PID: PID 190 SPN: 190 FMI: 2 Engine Crankshaft Speed/Position- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe crankshaft position and camshaft position sensors are Hall effect type sensors. The engine control module (ECM) provides a 5 volt supply to the position sensor and a return circuit. As the teeth on the crankshaft speed ring or the dimples in the back of the camshaft gear move past the position sensor, a signal is generated on the position sensor signal circuit. The ECM interprets this signal and converts it to an engine speed. A missing tooth on the crankshaft gear is used by the ECM to determine the position of the engine.

Component LocationThe crankshaft position and camshaft position sensor location varies, depending on engine model.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a loss of the crankshaft speed/position sensor while the engine was running.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The backup engine speed sensor will be used by the ECM for the engine speed signal.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkCauses of this fault include:

Open or short circuit of the +5-VDC supply, signal, or return wire in the engine harnessDamaged or malfunctioning engine speed sensorDamaged tone wheelSensor air gap that is too small or too large.

Possible Cause:1) Engine Wiring harness failure2) Sensor failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 687 PID: PID 103 SPN: 103 FMI: 18 Turbocharger 1 Speed- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 649 PID: SID 115 SPN: 1378 FMI: 31 Engine Oil Change Interval- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 629 PID: PID 314 SPN: 1176 FMI: 18 Turbocharger 1 Compressor Inlet Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 597 PID: PID 167 SPN: 167 FMI: 18 Electrical Charging System Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 596 PID: PID 167 SPN: 167 FMI: 16 Electrical Charging System Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 595 PID: PID 103 SPN: 103 FMI: 16 Turbocharger 1 Speed- Data Valid But Above Normal Operating Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 691 PID: PID 351 SPN: 1172 FMI: 3 Turbocharger 1 Compressor Intake Temperature Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe compressor intake air temperature sensor is a variable resistor sensor and is used to measure the temperature of the air entering the compressor intake of the turbocharger. The engine control module (ECM) supplies 5-VDC to the compressor intake temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the air temperature.

Component LocationThe turbocharger compressor intake temperature sensor is located in the compressor inlet of the turbocharger.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the compressor intake temperature signal voltage was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the compressor intake temperature reading is used.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe turbocharger compressor intake air temperature sensor shares return wires in the engine harness with other sensors. An open return can cause multiple fault codes to be active. Before troubleshooting Fault Code 691, check for multiple fault codes. An extension harness between the main engine harness and the turbocharger compressor intake temperature sensor can be used depending on the turbocharger arrangement.

Possible causes of this fault code include:

Open return circuit in the harness, connectors, or sensorOpen signal circuit or short circuit to a voltage sourceDamaged sensor.

Possible Cause:1) ECM failure2) Engine harness3) OEM harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 689 PID: PID 190 SPN: 190 FMI: 2 Engine Crankshaft Speed/Position- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 687 PID: PID 103 SPN: 103 FMI: 18 Turbocharger 1 Speed- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 649 PID: SID 115 SPN: 1378 FMI: 31 Engine Oil Change Interval- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 629 PID: PID 314 SPN: 1176 FMI: 18 Turbocharger 1 Compressor Inlet Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 597 PID: PID 167 SPN: 167 FMI: 18 Electrical Charging System Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 596 PID: PID 167 SPN: 167 FMI: 16 Electrical Charging System Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 692 PID: PID 351 SPN: 1172 FMI: 4 Turbocharger 1 Compressor Intake Temperature Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe turbocharger compressor intake temperature sensor is a variable resistor sensor and is used to measure the temperature of the air entering the compressor intake of the turbocharger. The engine control module (ECM) supplies 5-VDC to the compressor intake temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the air temperature.

Component LocationThe turbocharger compressor intake temperature sensor is located in the compressor inlet of the turbocharger.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the compressor intake temperature signal voltage was less than 0.05-VDC for more than 10 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the compressor intake temperature reading is used.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe turbocharger compressor intake air temperature sensor shares return wires in the engine harness with other sensors. An open return can cause multiple fault codes to be active. Before troubleshooting Fault Code 692, check for multiple fault codes. An extension harness between the main engine harness and the turbocharger compressor intake temperature sensor can be used depending on the turbocharger arrangement.

Possible causes of this fault code:

Signal circuit shorted to ground in the harnessSignal circuit shorted to return or ground in the sensorDamaged sensor.

Possible Cause:1) ECM failure2) Engine harness3) OEM harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 691 PID: PID 351 SPN: 1172 FMI: 3 Turbocharger 1 Compressor Intake Temperature Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 689 PID: PID 190 SPN: 190 FMI: 2 Engine Crankshaft Speed/Position- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 687 PID: PID 103 SPN: 103 FMI: 18 Turbocharger 1 Speed- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 649 PID: SID 115 SPN: 1378 FMI: 31 Engine Oil Change Interval- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 629 PID: PID 314 SPN: 1176 FMI: 18 Turbocharger 1 Compressor Inlet Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 597 PID: PID 167 SPN: 167 FMI: 18 Electrical Charging System Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6925 PID: SPN: 3216 FMI: 11/31 Aftertreatment 1 SCR Intake NOx Sensor – Condition Exists

Lamp:Amber

Reason:An incorrect NOx sensor reading has been detected by the aftertreatment intake NOx sensor.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment intake NOx (Nitrogen Oxides) sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component Location:The aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the Diagnostics:1. This diagnostic runs when the aftertreatment diesel oxidation catalyst intake temperature sensor has been above 150°C [302°F] for 5 minutes while the engine is running.2. This diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the aftertreatment intake NOx reading was higher or lower than the calculated aftertreatment intake NOx value for the engine operating conditions.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair, it may be necessary to operate the vehicle on a chassis dynamometer or to drive the vehicle in order to get the engine load high enough for the diagnostic to run.2. The fault code status displayed by the diagnostic tool will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. EGR system leaks.2. Exhaust system leaks.3. An incorrectly installed aftertreatment intake NOx sensor.4. An aftertreatment intake NOx sensor that has carbon buildup on the tip of the sensor.5. A malfunctioning EGR differential pressure sensor.6. A malfunctioning EGR valve.7. Excessive oil consumption.8. Possible engine misfire.9. The NOx sensor part number is incorrect.

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6815 PID: SPN: 3227 FMI: 2/21 Aftertreatment 1 Outlet Oxygen Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6814 PID: SPN: 3227 FMI: 2/20 Aftertreatment 1 Outlet Oxygen Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6813 PID: SPN: 3515 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6812 PID: SPN: 3515 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6811 PID: SPN: 4334 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6799 PID: SPN: 4334 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted High

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6926 PID: SPN: 3216 FMI: 14/14 Aftertreatment 1 SCR Intake NOx Sensor – Special Instructions

Lamp:Amber

Reason:An incorrect NOx sensor reading has been detected by the aftertreatment intake NOx sensor.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component Location:The aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the Diagnostics:1. This diagnostic runs when the aftertreatment diesel oxidation catalyst intake temperature sensor has been above 150°C [302°F] for 5 minutes while the engine is running.2. This diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the aftertreatment intake NOx reading was higher or lower than the calculated aftertreatment intake NOx value for the engine operating conditions.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair, it may be necessary to operate the vehicle on a chassis dynamometer or to drive the vehicle in order to get the engine load high enough for the diagnostic to run.2. The fault code status displayed by the diagnostic tool will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. EGR system leaks.2. Exhaust system leaks.3. An incorrectly installed aftertreatment intake NOx sensor.4. An aftertreatment intake NOx sensor that has carbon buildup on the tip of the sensor.5. A malfunctioning EGR differential pressure sensor.6. A malfunctioning EGR valve.7. Excessive oil consumption.8. Possible engine misfire.9. The NOx sensor part number is incorrect.

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6925 PID: SPN: 3216 FMI: 11/31 Aftertreatment 1 SCR Intake NOx Sensor – Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6815 PID: SPN: 3227 FMI: 2/21 Aftertreatment 1 Outlet Oxygen Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6814 PID: SPN: 3227 FMI: 2/20 Aftertreatment 1 Outlet Oxygen Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6813 PID: SPN: 3515 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6812 PID: SPN: 3515 FMI: 2/20 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor – Data Not Rational – Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6811 PID: SPN: 4334 FMI: 2/21 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Not Rational – Drifted Low

Leer más →