Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3571 PID: SPN: 4334 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe Engine Control Module (ECM) provides a 5 volt supply and a ground to the aftertreatment diesel exhaust fluid pressure sensor. The pressure sensor provides a signal to the ECM on the sensor signal circuit. This sensor signal voltage changes, based on the aftertreatment diesel exhaust fluid pressure supplied by the dosing unit. The ECM will detect a low signal voltage at low diesel exhaust fluid pressures, and a high signal voltage at high diesel exhaust fluid pressures.

Component LocationThe aftertreatment diesel exhaust fluid pressure sensor is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid pressure sensor signal voltage was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Signal wire shorted to sensor supply or battery voltageA malfunctioning aftertreatment diesel exhaust fluid pressure sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3568 PID: SPN: 5394 FMI: 7 Aftertreatment Diesel Exhaust Fluid (DEF) Dosing Valve- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3567 PID: SPN: 5394 FMI: 5 Aftertreatment Diesel Exhaust Fluid Dosing Valve- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3563 PID: SPN: 5491 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater Relay – Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3562 PID: SPN: 5491 FMI: 3 Aftertreatment Diesel Exhaust Fluid Line Heater relay – Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3559 PID: SPN: 3361 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3558 PID: SPN: 3361 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3572 PID: SPN: 4334 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe Engine Control Module (ECM) provides a 5 volt supply and a ground to the aftertreatment diesel exhaust fluid pressure sensor. The pressure sensor provides a signal to the ECM on the sensor signal circuit. This sensor signal voltage changes, based on the aftertreatment diesel exhaust fluid pressure supplied by the dosing unit. The ECM will detect a low signal voltage at low diesel exhaust fluid pressures, and a high signal voltage at high diesel exhaust fluid pressures.

Component LocationThe aftertreatment diesel exhaust fluid pressure sensor is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid pressure sensor signal voltage was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Signal wire shorted to groundA malfunctioning aftertreatment diesel exhaust fluid pressure sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3571 PID: SPN: 4334 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3568 PID: SPN: 5394 FMI: 7 Aftertreatment Diesel Exhaust Fluid (DEF) Dosing Valve- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3567 PID: SPN: 5394 FMI: 5 Aftertreatment Diesel Exhaust Fluid Dosing Valve- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3563 PID: SPN: 5491 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater Relay – Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3562 PID: SPN: 5491 FMI: 3 Aftertreatment Diesel Exhaust Fluid Line Heater relay – Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3559 PID: SPN: 3361 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3574 PID: SPN: 4334 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe Engine Control Module (ECM) provides a 5 volt supply and a ground to the aftertreatment diesel exhaust fluid pressure sensor. The pressure sensor provides a signal to the ECM on the sensor signal circuit. This sensor signal voltage changes, based on the aftertreatment diesel exhaust fluid pressure supplied by the dosing unit. The ECM will detect a low signal voltage at low diesel exhaust fluid pressures, and a high signal voltage at high diesel exhaust fluid pressures.

Component LocationThe aftertreatment diesel exhaust fluid pressure sensor is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs when the diesel exhaust fluid dosing unit is in the priming or dosing state.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid pressure was less than a threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Engine torque will be severely reduced.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeTo validate the repair, perform the “Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test” found under “ECM Diagnostic Tests” in the INSITE™ electronic service toolThe fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkTroubleshoot other active SCR related faults before this fault.

Possible causes of this fault code include:

Low diesel exhaust fluid tank levelBlocked, restricted, or frozen diesel exhaust fluid dosing unit supply lineBlocked or restricted diesel exhaust fluid tank filterBlocked or restricted diesel exhaust fluid dosing unit filterBlocked or restricted diesel exhaust fluid dosing unit supply line fittingMalfunctioning diesel exhaust fluid dosing unitContaminated diesel exhaust fluidDebris from the diesel exhaust fluid tank. If debris is found in the diesel exhaust fluid tank, clean the diesel exhaust fluid tank thoroughly and fill with certified diesel exhaust fluid.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) DEF tank filter failure2) Aftertreatment DEF dosing unit intake fitting failure3) DEF tank vent filter, DEF suction line failure4) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3572 PID: SPN: 4334 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3571 PID: SPN: 4334 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3568 PID: SPN: 5394 FMI: 7 Aftertreatment Diesel Exhaust Fluid (DEF) Dosing Valve- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3567 PID: SPN: 5394 FMI: 5 Aftertreatment Diesel Exhaust Fluid Dosing Valve- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3563 PID: SPN: 5491 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater Relay – Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3562 PID: SPN: 5491 FMI: 3 Aftertreatment Diesel Exhaust Fluid Line Heater relay – Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3575 PID: SPN: 4334 FMI: 16 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe Engine Control Module (ECM) provides a 5 volt supply and a ground to the aftertreatment diesel exhaust fluid pressure sensor. The pressure sensor provides a signal to the ECM on the sensor signal circuit. This sensor signal voltage changes, based on the aftertreatment diesel exhaust fluid pressure supplied by the dosing unit. The ECM will detect a low signal voltage at low diesel exhaust fluid pressures, and a high signal voltage at high diesel exhaust fluid pressures.

Component LocationThe aftertreatment diesel exhaust fluid pressure sensor is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid pressure was greater than 1100 kpa [159 psi] for more than 20 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Engine torque will be severely reduced.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeTo validate the repair, perform the “Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test” found under “ECM Diagnostic Tests” in the INSITE™ electronic service toolThe fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkTroubleshoot other active SCR related faults before this fault.

Possible causes of this fault code include:

Blocked, restricted, or frozen diesel exhaust fluid dosing unit return line or return line fittingMalfunctioning diesel exhaust fluid dosing unit.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DEF dosing unit filter failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3574 PID: SPN: 4334 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3572 PID: SPN: 4334 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3571 PID: SPN: 4334 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3568 PID: SPN: 5394 FMI: 7 Aftertreatment Diesel Exhaust Fluid (DEF) Dosing Valve- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3567 PID: SPN: 5394 FMI: 5 Aftertreatment Diesel Exhaust Fluid Dosing Valve- Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3563 PID: SPN: 5491 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater Relay – Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3577 PID: SPN: 4376 FMI: 3 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid return valve is controlled by the Engine Control Module (ECM). The return valve position determines where diesel exhaust fluid will flow as it exits the dosing unit. When the return valve is activated, the dosing system will purge and return the diesel exhaust fluid in the lines to the tank.

Component LocationThe aftertreatment diesel exhaust fluid return valve is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid return valve circuit was out of range high or open.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf this fault is active, the dosing system may not be able to purge, which means there will be aftertreatment diesel exhaust fluid left in the lines. Care must be taken when removing connections. Also, lines can freeze and the SCR system can become damaged in cold weather if the system is not properly purged.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DEF dosing unit failure2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3575 PID: SPN: 4334 FMI: 16 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3574 PID: SPN: 4334 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3572 PID: SPN: 4334 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3571 PID: SPN: 4334 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3568 PID: SPN: 5394 FMI: 7 Aftertreatment Diesel Exhaust Fluid (DEF) Dosing Valve- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3567 PID: SPN: 5394 FMI: 5 Aftertreatment Diesel Exhaust Fluid Dosing Valve- Current Below Normal or Open Circuit

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3578 PID: SPN: 4376 FMI: 4 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid return valve is controlled by the Engine Control Module (ECM). The return valve position determines where diesel exhaust fluid will flow as it exits the dosing unit. When the return valve is activated, the dosing system will purge and return the diesel exhaust fluid in the lines to the tank.

Component LocationThe aftertreatment diesel exhaust fluid return valve is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic only runs when the aftertreatment diesel exhaust fluid dosing system is purging.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid return valve voltage was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf this fault is active, the dosing system may not be able to purge, which means there will be diesel exhaust fluid left in the lines. Care must be taken when removing connections. Also, lines could freeze and become damaged in cold weather if the system is not properly purged.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DEF dosing unit failure2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3577 PID: SPN: 4376 FMI: 3 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3575 PID: SPN: 4334 FMI: 16 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3574 PID: SPN: 4334 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3572 PID: SPN: 4334 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3571 PID: SPN: 4334 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3568 PID: SPN: 5394 FMI: 7 Aftertreatment Diesel Exhaust Fluid (DEF) Dosing Valve- Mechanical System Not Responding or Out of Adjustment

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3582 PID: SPN: 4364 FMI: 18 Aftertreatment SCR Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe engine control module (ECM) monitors the NOx concentration in the engine’s exhaust gases using an aftertreatment intake NOx sensor and an aftertreatment outlet NOx sensor. By comparing these two values, the ECM is able to determine the conversion efficiency of the SCR catalyst and dosing system.

Component LocationThe SCR catalyst is located in the vehicle’s exhaust system, after the diesel particulate filter and decomposition tube.

Conditions for Running the DiagnosticsThis diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the NOx conversion across the SCR catalyst was less than expected.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeIt is necessary to use the “Reset All Faults” command in INSITE™ electronic service tool to clear this fault and extinguish the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL).

Shop TalkTroubleshoot all other active NOx sensor and SCR dosing system related fault codes before this fault.

Possible causes of this fault code include:

Malfunctioning diesel exhaust fluid dosing systemExhaust system leaksMalfunctioning SCR catalystDegraded, diluted, or incorrect diesel exhaust fluidDiesel exhaust fluid deposits in the decomposition tube.For unit that has come back into with repeat failures consider the possibility that customer is not using Ultra-low sulfur Diesel fuel

Possible Cause:1) ECM calibration2) DEF fluid could be Contaminated3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3578 PID: SPN: 4376 FMI: 4 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3577 PID: SPN: 4376 FMI: 3 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3575 PID: SPN: 4334 FMI: 16 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3574 PID: SPN: 4334 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3572 PID: SPN: 4334 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3571 PID: SPN: 4334 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3583 PID: SPN: 5031 FMI: 10 Aftertreatment Outlet Nox Sensor Heater- Abnormal Rate of Change

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR outlet temperature has been above 200°C [392° F] for 60 seconds while the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the NOx sensor heater was unable to maintain its normal operating temperature.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe NOx sensor heater is internal to the NOx sensor assembly, and can not be serviced separately.

Possible causes of this fault code include:

A damaged aftertreatment outlet NOx sensorIntermittent power connection to the aftertreatment outlet NOx sensor.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Loose Connections2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3582 PID: SPN: 4364 FMI: 18 Aftertreatment SCR Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3578 PID: SPN: 4376 FMI: 4 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3577 PID: SPN: 4376 FMI: 3 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3575 PID: SPN: 4334 FMI: 16 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3574 PID: SPN: 4334 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3572 PID: SPN: 4334 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3596 PID: SPN: 4334 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe Engine Control Module (ECM) provides a 5 volt supply and a ground to the aftertreatment diesel exhaust fluid pressure sensor. The pressure sensor provides a signal to the ECM on the sensor signal circuit. This sensor signal voltage changes, based on the aftertreatment diesel exhaust fluid pressure supplied by the dosing unit. The ECM will detect a low signal voltage at low diesel exhaust fluid pressures, and a high signal voltage at high diesel exhaust fluid pressures.

Component LocationThe aftertreatment diesel exhaust fluid pressure sensor is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs when diesel exhaust fluid dosing unit is fully primed, and is actively maintaining diesel exhaust fluid pressure in the dosing system.

Conditions for Setting the Fault CodesThe diesel exhaust fluid dosing unit was unable to maintain the commanded diesel exhaust fluid pressure.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform the “Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test” found under “ECM Diagnostic Tests” in the INSITE™ electronic service toolThe fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Leaking diesel exhaust fluid linesMalfunctioning diesel exhaust fluid dosing unitBlocked or restricted diesel exhaust fluid dosing unit supply line fittingBlocked or restricted diesel exhaust fluid filtersMalfunctioning diesel exhaust fluid pressure sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DEF dosing unit failure2) OEM harness3) DEF fluid not Certified4) Aftertreatment DEF dosing unit intake fitting failure5) DEF tank filter, DEF tank vent filter, DEF suction line failure6) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3583 PID: SPN: 5031 FMI: 10 Aftertreatment Outlet Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3582 PID: SPN: 4364 FMI: 18 Aftertreatment SCR Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3578 PID: SPN: 4376 FMI: 4 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3577 PID: SPN: 4376 FMI: 3 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3575 PID: SPN: 4334 FMI: 16 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3574 PID: SPN: 4334 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level

Leer más →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3649 PID: SPN: 5024 FMI: 10 Aftertreatment Intake Nox Sensor Heater- Abnormal Rate of Change

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftetreatment diesel oxidation catalsyst intake temperature sensor has been above 150° C [302° F] for 5 seconds while the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the NOx sensor heater was unable to maintain its normal operating temperature.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment diesel oxidation catalyst intake temperature must be above 150° C [302° F] for 5 seconds before the aftertreatment intake NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe NOx sensor heater is internal to the NOx sensor assembly, and can not be serviced separately.

Possible causes of this fault code include:

Damaged aftertreatment intake NOx sensorIntermittent power connection to the aftertreatment intake NOx sensor.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Loose Connections2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3596 PID: SPN: 4334 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3583 PID: SPN: 5031 FMI: 10 Aftertreatment Outlet Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3582 PID: SPN: 4364 FMI: 18 Aftertreatment SCR Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3578 PID: SPN: 4376 FMI: 4 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3577 PID: SPN: 4376 FMI: 3 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3575 PID: SPN: 4334 FMI: 16 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level