Ir directamente al contenido Ir directamente al menú lateral

Cumminz

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe air shutoff valve is an optional component used to shutdown the engine in the event of an engine overspeed condition. It can be closed via a manual shutdown switch or via an ECM command.

Component LocationThe engine air shutoff valve location can vary depending on the OEM. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine speed was greater than 2500 RPM for 0.25 seconds, or the operator manually tripped the engine air shutoff valve.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The air shutoff valve closesThe engine will be shut down.

Conditions for Clearing the Fault CodeThe air shutoff valve must be reset to the open position.To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code indicates that the engine has been shut down via the engine air shutoff valve. This can occur automatically (engine overspeed condition) or manually (activating the engine air shutoff valve switch in the cab). In either case, this fault code will become active until the valve de-activated.

Possible Cause:1) Engine damage2) Crankshaft engine speed sensor, or Camshaft engine position sensor3) ECM failure

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2387 PID: SID 27 SPN: 641 FMI: 7 VGT Actuator Driver Circuit (Motor)- Mechanical System Not Responding or Out Of Adjustment

Leer más →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 249 PID: PID 171 SPN: 171 FMI: 3 Ambient Air Temperature Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe ambient air temperature sensor is a variable resistor sensor and is used to measure the temperature of the ambient air. The engine control module (ECM) uses this temperature reading to optimize engine performance, and determine if heating of the SCR system is required. The engine control module (ECM) supplies 5 volts to the ambient air temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the ambient air temperature.

Component LocationThe mounting location for the ambient air temperature sensor is OEM dependent. Refer to the appropriate OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the ambient air temperature signal voltage was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.A default value for the ambient air temperature reading is used.Active and stationary regeneration of the diesel particulate filter will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Open return circuit in the harness, connectors, or sensorOpen signal circuit or shorted to a voltage source.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 242 PID: PID 84 SPN: 84 FMI: 10 Wheel-Based Vehicle Speed Sensor Circuit Tampering Has Been Detected- Abnormal Rate of Change
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 241 PID: PID 84 SPN: 84 FMI: 2 Wheel-Based Vehicle Speed- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 238 PID: PID 105 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 235 PID: PID 111 SPN: 111 FMI: 1 Coolant Level- Data Valid But Below Normal Operational Range- Most Severe Level

Leer más →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the engine control module (ECM) to control emissions and exhaust gas recirculation (EGR) valve operation. The ECM provides a 5 volt supply to the exhaust gas pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The exhaust gas pressure sensor provides a signal to the ECM on the exhaust gas pressure sensor signal circuit. This sensor signal voltage changes, based on the pressure in the exhaust manifold.

Component LocationThe exhaust gas pressure sensor is located above the front section of the exhaust manifold and is plumbed into the exhaust manifold.

Conditions for Running the DiagnosticsThis diagnostic consists of two parts:

One part runs immediately after the keyswitch is turned OFF, and the engine coolant temperature is above 70°C or 158°F.

The second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the exhaust pressure reading was higher or lower than the other absolute pressure sensors when the keyswitch is OFF and the engine is not running.The Engine Control Module (ECM) detected the exhaust pressure was higher or lower than expected during normal engine operation.Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value is used for the exhaust gas pressure sensor reading.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, first ensure the engine coolant temperature is above 70°C or 158°F. Operate the engine if necessary.Cycle the keyswitch to the ON position for 30 seconds, then cycle the keyswitch to the OFF position for 30 seconds. Start the engine and run it at high idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Stuck in-range exhaust gas pressure sensor readingHigh resistance in the exhaust gas pressure sensor signal or return linesPlugging or restriction in the exhaust gas pressure sensor tubeLeaks in the exhaust system

Possible Cause:1) Engine harness2) ECM calibration

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect

Leer más →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 256 PID: PID 171 SPN: 171 FMI: 4 Ambient Air Temperature Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe ambient air temperature sensor is a variable resistor sensor and is used to measure the temperature of the ambient air. The engine control module (ECM) uses this temperature reading to optimize engine performance, and determine if heating of the SCR system is required. The engine control module (ECM) supplies 5 volts to the ambient air temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the ambient air temperature.

Component LocationThe mounting location for the ambient air temperature sensor is OEM dependent. Refer to the appropriate OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the ambient air temperature signal voltage was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.A default value for the ambient air temperature reading is used.Active and stationary regeneration of the diesel particulate filter will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe ambient air temperature sensor shares return wires in the engine harness with other sensors. Opens and shorts in the engine harness can cause multiple fault codes to be active. Check fault codes with multiple counts first.

Possible causes of this fault code include:

Signal shorted to ground in the harnessSignal shorted to return or ground in the sensor.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 249 PID: PID 171 SPN: 171 FMI: 3 Ambient Air Temperature Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 242 PID: PID 84 SPN: 84 FMI: 10 Wheel-Based Vehicle Speed Sensor Circuit Tampering Has Been Detected- Abnormal Rate of Change
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 241 PID: PID 84 SPN: 84 FMI: 2 Wheel-Based Vehicle Speed- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 238 PID: PID 105 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit- Voltage Below Normal or Shorted to Low Source

Leer más →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2634 PID: SID 027 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Variable Geometry Turbocharger (VGT) detected an internal error in the VGT smart device.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.

VGT actuation will be disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code is logged when the VGT smart actuator detected an internal error within the VGT actuator. The VGT actuator will stop controlling the turbocharger when this fault code is active.

Fault Code 2634 will become active if the VGT actuator is removed from the turbocharger and then the keyswitch is turned to the ON position; or it may be possible for it to become active if the actuator fails the install/calibrate procedure. If this occurs, disconnect the VGT actuator from the engine harness with the keyswitch ON, and connect the VGT actuator to the engine harness. Fault Code 2634 should go inactive. Follow the VGT actuator installation procedure to install the VGT actuator.

Possible Cause:1) VGT actuator failure2) ECM calibration

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration

Leer más →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2635 PID: SPN: 641 FMI: 31 VGT Actuator Driver Circuit- Condition Exists

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThis fault code can be activated for the following reasons:

The Engine Control Module (ECM) detected a calibration incompatibility between the VGT actuator and the ECM calibration.The Variable Geometry Turbocharger (VGT) detected the system voltage was incorrect for the VGT actuator part number.The Engine Control Module (ECM) detected an incorrect VGT actuator installed on the turbocharger.Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.

VGT actuation will be disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code is logged when the ECM has detected that an incorrect VGT actuator has been installed on the turbocharger.

Possible Cause:1) ECM code incorrect for Engine CPL2) ECM calibration

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2634 PID: SID 027 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level

Leer más →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2636 PID: SID 27 SPN: 641 FMI: 9 VGT Actuator Driver Circuit- Abnormal Update Rate

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) did not receive a valid J1939 data link message from the Variable Geometry Turbocharger (VGT) actuator for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.

VGT actuation will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

The VGT actuator is not receiving power from the ECM. This can be caused by an open circuit in the power supply wire or low voltage supplied by the primary engine ECM.Rapid cycling of the keyswitchAn open return circuit on the VGT actuator circuitAn open or short circuit on the J1939 data link circuit between the ECM and VGT actuatorIntermittent communications between the VGT actuator and the primary engine ECM on the J1939 data linkA damaged termination resistor in the engine data link harness

Possible Cause:1) VGT Actuator failure2) Intake NOx sensor failure3) Engine wiring harness4) OEM terminating resistor failure5) OEM wiring harness6) ECM calibration

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2635 PID: SPN: 641 FMI: 31 VGT Actuator Driver Circuit- Condition Exists
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2634 PID: SID 027 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration

Leer más →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2637 (X) PID: SID 380 SPN: 5018 FMI: 11 Aftertreatment Diesel Oxidation Catalyst face Plugged- Root Cause Not Known

Circuit DescriptionThe aftertreatment temperature sensors are used by the engine control module (ECM) to monitor the engine exhaust temperatures in the aftertreatment system. The aftertreatment temperature sensors are thermistors and change resistance based on the temperature being measured. The ECM provides a 5 volt reference voltage to the sensor. The ECM monitors the change in signal voltage and converts this to a temperature value.

Component LocationThe aftertreatment diesel oxidation catalyst is located in the exhaust system. The location of the catalyst can vary, depending on the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running and active regeneration of the aftertreatment diesel particulate filter is occurring.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the intake face of the diesel oxidation catalyst was plugged with soot.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodePerform INSITE™ electronic service tool Diesel Oxidation Catalyst Maintenance Reset procedure found under the Aftertreatment Maintenance section of Advanced ECM Data.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code is set when the inlet face of the diesel oxidation catalyst is detected to be plugged with soot.

Possible causes of this fault code include:

Engine oil or fuel plugging the front face of the aftertreatment diesel oxidation catalyst.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and data link communication issues with aftertreatment components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing, or intermittent connections.

NOTE: This fault code is only used to assist in troubleshooting Fault Codes 3151, 3543, and/or 3582.

Possible Cause:1) Aftertreatment Injector2) ECM calibration

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2636 PID: SID 27 SPN: 641 FMI: 9 VGT Actuator Driver Circuit- Abnormal Update Rate
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2635 PID: SPN: 641 FMI: 31 VGT Actuator Driver Circuit- Condition Exists
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2634 PID: SID 027 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Leer más →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2638 PID: SID 380 SPN: 5298 FMI: 17 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Least Severe Level

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel oxidation catalyst is located in the exhaust system. The location of the catalyst can vary, depending on the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running and active regeneration of the aftertreatment diesel particulate filter is occurring.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) calculated the DOC efficiency was less than required to successfully complete a regeneration.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and perform the INSITE™ electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning diesel oxidation catalystA malfunctioning aftertreatment fuel injector

Possible Cause:1) Aftertreatment Fuel Injector2) ECM calibration

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2637 (X) PID: SID 380 SPN: 5018 FMI: 11 Aftertreatment Diesel Oxidation Catalyst face Plugged- Root Cause Not Known
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2636 PID: SID 27 SPN: 641 FMI: 9 VGT Actuator Driver Circuit- Abnormal Update Rate
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2635 PID: SPN: 641 FMI: 31 VGT Actuator Driver Circuit- Condition Exists
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2634 PID: SID 027 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level

Leer más →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2639 PID: SID 324 SPN: 3251 FMI: 15 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Least Severe Level

Circuit DescriptionThe engine aftertreatment system monitors the soot load in the aftertreatment diesel particulate filter. Under normal operating conditions, the aftertreatment diesel particulate filter is self-cleaning, where soot is converted to carbon dioxide, nitrogen, and water. Under light load operating conditions, it can be necessary to perform a stationary regeneration of the aftertreatment diesel particulate filter. The soot load in the aftertreatment diesel particulate filter is estimated, using the aftertreatment differential pressure sensor and the calculated soot output of the engine.

Component LocationThe aftertreatment diesel particulate filter is located in the exhaust system and is installed by the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the soot load of the aftertreatment diesel particulate filter had reached the first stage of plugging.

Action Taken When the Fault Code is ActiveThe ECM will illuminate the aftertreatment diesel particulate filter lamp immediately after the diagnostic is set.The ECM will flash the aftertreatment dash lamp as the severity of the soot load increases.Torque output of the engine will be reduced as the soot load in the aftertreatment diesel particulate filter increases.Conditions for Clearing the Fault CodeAfter completing a stationary regeneration (as instructed in this fault code troubleshooting tree) and no additional faults become active, the repair has been validated.

The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the aftertreatment diesel particulate filter lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkNote: This fault code indicates that the aftertreatment diesel particulate filter requires maintenance by performing a stationary regeneration procedure. This is a maintenance procedure only and is not covered by Cummins Inc. warranty.

Note: Repeated occurrences of this fault code may indicate the engine requires frequent regeneration. Refer to symptom tree t147 (Aftertreatment Diesel Particulate Filter-Excessive Automatic and/or Stationary Regeneration) to identify the cause of frequent regeneration.

Possible causes of this fault code include:

The engine has been operating in light load operating conditions that prevent exhaust temperatures from being high enough to regenerate the aftertreatment diesel particulate filterPossible engine damage that causes excessive black smoke to be generated.

Possible Cause:1) ECM calibration

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2638 PID: SID 380 SPN: 5298 FMI: 17 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2637 (X) PID: SID 380 SPN: 5018 FMI: 11 Aftertreatment Diesel Oxidation Catalyst face Plugged- Root Cause Not Known
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2636 PID: SID 27 SPN: 641 FMI: 9 VGT Actuator Driver Circuit- Abnormal Update Rate
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2635 PID: SPN: 641 FMI: 31 VGT Actuator Driver Circuit- Condition Exists
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2634 PID: SID 027 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect

Leer más →