Ir directamente al contenido Ir directamente al menú lateral

Cumminz

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7866 PID: SPN: 108 FMI: 10/10 Barometric Pressure – Abnormal Rate of Change

Lamp:Amber

Reason:An error in the barometric pressure sensor signal was detected by the ECM.

Effect:Possible reduced engine performance.

Circuit Description:The barometric pressure sensor responds to pressure changes in the atmospheric pressure. The pressure changes occur based on the elevation where the engine is presently operating. The barometric pressure sensor has a 5 volt supply circuit, a sensor signal voltage, and a return circuit.

Component Location:The barometric pressure sensor is mounted on the main branch of the engine harness near the ECM.

Conditions for Running the Diagnostic:This diagnostic runs immediately after the keyswitch is turned OFF.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the barometric pressure reading was higher or lower than the other absolute pressure sensors on the engine, or an in-range malfunction of the sensor was detected.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.2. A default value for the barometric pressure reading is used.3. Exhaust Gas Recirculation (EGR) valve operation will be disabled.4. Diesel exhaust fluid injection into the aftertreatment system is disabled.5. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair, start the engine, let it idle for 1 minute, and then shutdown the engine.2. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.3. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.4. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:A malfunctioning barometric air pressure sensor.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7864 PID: SPN: 1209 FMI: 10/10 Exhaust Gas Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7863 PID: SPN: 171 FMI: 10/10 Ambient Air Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7861 PID: SPN: 1172 FMI: 10/10 Turbocharger 1 Compressor Intake Temperature Sensor – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7583 PID: SPN: 102 FMI: 0/15 Intake Manifold 1 Pressure – Data Valid But Above Normal Operating Range – Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7582 PID: SPN: 1209 FMI: 1/17 Exhaust Gas Pressure – Data Valid But Below Normal Operating Range – Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7436 PID: SPN: 1176 FMI: 2/20 Engine Turbocharger 1 Compressor Intake Pressure – Data Not Rational – Drifted High

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7894 PID: SPN: 3246 FMI: 10/10 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature – Abnormal Rate of Change

Lamp:Amber

Reason:The aftertreatment diesel particulate filter outlet temperature is not changing with engine operating conditions.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment exhaust gas temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment exhaust gas temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment exhaust gas temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, aftertreatment diesel particulate filter outlet temperature, and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment exhaust gas temperature sensor module and can not be replaced individually.

Component Location:The aftertreatment diesel particulate filter outlet temperature sensor is located in the aftertreatment system. It is located at the outlet of the aftertreatment diesel particulate filter.

Conditions for Running the Diagnostic:The engine must be turned OFF for period of 8 hours before this diagnostic will run. This diagnostic runs when the keyswitch is turned to the ON position after an 8 hour cold soak.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the aftertreatment diesel particulate filter outlet temperature sensor reading was higher or lower than the other temperature sensors on the engine after an extended period of engine off time.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or malfunction indicator lamp (MIL) after the diagnostic fails on two consecutive trips.2. A default value for the aftertreatment diesel particulate filter outlet temperature sensor reading is used.3. Diesel exhaust fluid injection into the aftertreatment system is disabled.4. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair, the engine must be shut down with the keyswitch in the OFF position for 8 hours. After the 8 hour cold soak turn the keyswitch to the ON position for 30 seconds.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. A malfunctioning aftertreatment diesel particulate filter intake temperature sensor.2. A malfunctioning aftertreatment diesel particulate filter outlet temperature sensor.3. Build up or plugging on the inlet face of the diesel particulate filter.4. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.5. For intermittent power supply and datalink communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7866 PID: SPN: 108 FMI: 10/10 Barometric Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7864 PID: SPN: 1209 FMI: 10/10 Exhaust Gas Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7863 PID: SPN: 171 FMI: 10/10 Ambient Air Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7861 PID: SPN: 1172 FMI: 10/10 Turbocharger 1 Compressor Intake Temperature Sensor – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7583 PID: SPN: 102 FMI: 0/15 Intake Manifold 1 Pressure – Data Valid But Above Normal Operating Range – Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7582 PID: SPN: 1209 FMI: 1/17 Exhaust Gas Pressure – Data Valid But Below Normal Operating Range – Least Severe Level

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7896 PID: SPN: 7896 FMI: 11/31 Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Condition Exists

Lamp:Amber

Reason:The aftertreatment diesel exhaust fluid tank level has fallen below the critical warning level.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment diesel exhaust fluid level sensor is used to monitor the diesel exhaust fluid level inside the diesel exhaust fluid tank.

Component Location:The aftertreatment diesel exhaust fluid tank level sensor is located in the aftertreatment diesel exhaust fluid tank. Location of the tank and level sensor is OEM dependent.

Conditions for Running the Diagnostic:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes:The diesel exhaust fluid tank was critically low.

Action Taken When the Fault Code is Active:1. The diesel exhaust fluid lamp will be flashing.2. The ECM illuminates the amber check engine lamp immediately when the diagnostic runs and fails.3. Engine torque will be severely reduced.4. Vehicle speed will be limited to 8 km [5 mi] per hour after the engine has been shutdown, 1 hour of engine idle time, or the fuel tank has been refilled.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:This fault code indicates that the Diesel Exhaust Fluid (DEF) level is critically low and there will be a power loss. Engine power will be reduced automatically.This can be corrected by refilling the DEF tank. Normal engine power will be restored after refilling the DEF tank.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7894 PID: SPN: 3246 FMI: 10/10 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7866 PID: SPN: 108 FMI: 10/10 Barometric Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7864 PID: SPN: 1209 FMI: 10/10 Exhaust Gas Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7863 PID: SPN: 171 FMI: 10/10 Ambient Air Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7861 PID: SPN: 1172 FMI: 10/10 Turbocharger 1 Compressor Intake Temperature Sensor – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7583 PID: SPN: 102 FMI: 0/15 Intake Manifold 1 Pressure – Data Valid But Above Normal Operating Range – Least Severe Level

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7935 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change

Lamp:Amber

Reason:The EGR temperature sensor is reading an erratic value at initial key ON or while the engine is running.

Effect:Possible reduced engine performance.

Circuit Description:The Exhaust Gas Recirculation (EGR) temperature sensor is a variable resistor sensor and is used to measure the temperature of the EGR gas flow after it exits the EGR cooler. The Engine Control Module (ECM) supplies 5 volts to the EGR temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the EGR flow temperature.The EGR temperature value is used by the ECM for the engine protection system and engine emissions control.

Component Location:The EGR temperature sensor is located on the EGR connection tube between the EGR cooler and the air intake connection.

Conditions for Running the Diagnostic:The engine must be turned OFF for period of 8 hours before this diagnostic will run. This diagnostic runs when the keyswitch is turned to the ON position after an 8 hour cold soak.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the EGR temperature reading was higher or lower than the other temperature sensors on the engine after an extended period of engine off time.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.2. Diesel exhaust fluid injection into the aftertreatment system is disabled.3. Active and stationary regeneration of the diesel particulate filter will be disabled.4. Exhaust gas recirculation (EGR) valve operation will be disabled.5. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair, the engine must be shut down with the keyswitch in the OFF position for 8 hours. After the 8 hour cold soak turn the keyswitch to the ON position for 30 seconds.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Stuck in-range EGR temperature sensor.2. High resistance in the EGR temperature sensor signal or return wires.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7896 PID: SPN: 7896 FMI: 11/31 Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7894 PID: SPN: 3246 FMI: 10/10 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7866 PID: SPN: 108 FMI: 10/10 Barometric Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7864 PID: SPN: 1209 FMI: 10/10 Exhaust Gas Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7863 PID: SPN: 171 FMI: 10/10 Ambient Air Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7861 PID: SPN: 1172 FMI: 10/10 Turbocharger 1 Compressor Intake Temperature Sensor – Abnormal Rate of Change

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8154 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change

Lamp:Amber

Reason:The EGR temperature sensor is reading an erratic value at initial key ON or while the engine is running.

Effect:Possible reduced engine performance.

Circuit Description:The Exhaust Gas Recirculation (EGR) temperature sensor is a variable resistor sensor and is used to measure the temperature of the EGR gas flow after it exits the EGR cooler. The Engine Control Module (ECM) supplies 5 volts to the EGR temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the EGR flow temperature. The EGR temperature value is used by the ECM for the engine protection system and engine emissions control.

Component Location:The EGR temperature sensor is located on the EGR connection tube between the EGR cooler and the air intake connection.

Conditions for Running the Diagnostic:The engine must be turned OFF for period of 8 hours before this diagnostic will run. This diagnostic runs when the keyswitch is turned to the ON position after an 8 hour cold soak.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the EGR temperature reading was higher or lower than the other temperature sensors on the engine after an extended period of engine off time.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.2. Diesel exhaust fluid injection into the aftertreatment system is disabled.3. Active and stationary regeneration of the diesel particulate filter will be disabled.4. Exhaust Gas Recirculation (EGR) valve operation will be disabled.5. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair, the engine must be shut down with the keyswitch in the OFF position for 8 hours. After the 8 hour cold soak turn the keyswitch to the ON position for 30 seconds.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Stuck in-range EGR temperature sensor.2. High resistance in the EGR temperature sensor signal or return wires.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7935 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7896 PID: SPN: 7896 FMI: 11/31 Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7894 PID: SPN: 3246 FMI: 10/10 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7866 PID: SPN: 108 FMI: 10/10 Barometric Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7864 PID: SPN: 1209 FMI: 10/10 Exhaust Gas Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7863 PID: SPN: 171 FMI: 10/10 Ambient Air Temperature – Abnormal Rate of Change

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8155 PID: SPN: 521209 FMI: 12/12 Connectivity Module – Bad Intelligent Device or Component

Lamp:None

Reason:An error with connectivity module has been detected.

Effect:None on performance.

Circuit Description:The connectivity module is the data logging device. The connectivity module system collects data from the ECM via the vehicle J1939 network.The connectivity module is also the predictive cruise control system. The predictive cruise control system sends commands to the ECM via the vehicle J1939 network. Predictive cruise control dynamically adjust the vehicle speed profile while the vehicle is operating in cruise control. The vehicle speed profile is optimized for fuel economy based on the upcoming road grade.

Component Location:The connectivity module is either located on the engine or in the vehicle cabin.

Conditions for Running the Diagnostic:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes:The connectivity module reported an internal error of the connectivity module.

Action Taken When the Fault Code is Active:1. The ECM logs the fault code immediately when the diagnostic runs and fails.2. The connectivity module may not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 2 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.

Shop Talk:Possible causes of this fault code include:A malfunctioning connectivity module.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8154 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7935 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7896 PID: SPN: 7896 FMI: 11/31 Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7894 PID: SPN: 3246 FMI: 10/10 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7866 PID: SPN: 108 FMI: 10/10 Barometric Pressure – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7864 PID: SPN: 1209 FMI: 10/10 Exhaust Gas Pressure – Abnormal Rate of Change

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8156 PID: SPN: 521209 FMI: 9/9 Connectivity Module – Abnormal Update Rate

Lamp:None

Reason:Loss of communication with the connectivity module.

Effect:None on performance.

Circuit Description:The connectivity module is the data logging device. The connectivity module system collects data from the ECM via the vehicle J1939 network.The connectivity module is also the predictive cruise control system. The predictive cruise control system sends commands to the ECM via the vehicle J1939 network. Predictive cruise control dynamically adjust the vehicle speed profile while the vehicle is operating in cruise control. The vehicle speed profile is optimized for fuel economy based on the upcoming road grade.

Component Location:The connectivity module is either located on the engine or in the vehicle cabin.

Conditions for Running the Diagnostic:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) did not receive an expected message from the connectivity module.

Action Taken When the Fault Code is Active:1. The ECM logs the fault code immediately when the diagnostic runs and fails.2. The connectivity module may not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 2 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.3. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. The connectivity module is not receiving power. This can be caused by an open circuit in the power supply wire.2. Rapid cycling of the keyswitch.3. An open or short circuit on the J1939 data link circuit between the ECM and connectivity module.4. Intermittent communications between the connectivity module and the primary engine ECM on the J1939 data link.5. A damaged termination resistor in the J1939 data link.6. A malfunctioning connectivity module.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8155 PID: SPN: 521209 FMI: 12/12 Connectivity Module – Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8154 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7935 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7896 PID: SPN: 7896 FMI: 11/31 Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7894 PID: SPN: 3246 FMI: 10/10 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7866 PID: SPN: 108 FMI: 10/10 Barometric Pressure – Abnormal Rate of Change

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8157 PID: SPN: 521209 FMI: 11/31 Connectivity Module – Condition Exists

Lamp:None

Reason:The internal temperature of the connectivity module is above the warning limits.

Effect:None on performance.

Circuit Description:The connectivity module is the data logging device. The connectivity module system collects data from the ECM via the vehicle J1939 network.The connectivity module is also the predictive cruise control system. The predictive cruise control system sends commands to the ECM via the vehicle J1939 network. Predictive cruise control dynamically adjust the vehicle speed profile while the vehicle is operating in cruise control. The vehicle speed profile is optimized for fuel economy based on the upcoming road grade.

Component Location:The connectivity module in equipped with an internal temperature sensor, which monitors the temperature inside the module during operation. This temperature sensor is internal to the connectivity module and cannot be service separately.

Conditions for Running the Diagnostic:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes:The internal temperature of the connectivity module was greater than 105°F [221°C] for more than 5 seconds.

Action Taken When the Fault Code is Active:1. The ECM logs the fault code immediately when the diagnostic runs and fails.2. The connectivity module is put into sleep mode.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Inadequate air flow to cool connectivity module.2. Improper mounting of connectivity module.3. A malfunctioning connectivity module.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8156 PID: SPN: 521209 FMI: 9/9 Connectivity Module – Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8155 PID: SPN: 521209 FMI: 12/12 Connectivity Module – Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8154 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7935 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7896 PID: SPN: 7896 FMI: 11/31 Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7894 PID: SPN: 3246 FMI: 10/10 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature – Abnormal Rate of Change

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8179 PID: SPN: 8179 FMI: 9/9 Automated Driving System TSC1-P7 – Abnormal Update Rate

Lamp:None

Reason:Loss of communication with automated driving system.

Effect:Automated driving system will not operate.

Circuit Description:The automated driving system sends commands to the ECM via the J1939 data link to limit engine speed and maintain current cruise control set speed.

Component Location:The SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the Diagnostic:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) did not receive an expected message from the automated driving system.

Action Taken When the Fault Code is Active:1. The ECM logs the fault code immediately when the diagnostic runs and fails.2. The automated driving system will not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.3. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8157 PID: SPN: 521209 FMI: 11/31 Connectivity Module – Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8156 PID: SPN: 521209 FMI: 9/9 Connectivity Module – Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8155 PID: SPN: 521209 FMI: 12/12 Connectivity Module – Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8154 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7935 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7896 PID: SPN: 7896 FMI: 11/31 Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Condition Exists

Leer más →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8194 PID: SPN: 2852 FMI: 12/12 Communications Service Subscriber Identification Module – Bad Intelligent Device or Component

Lamp:None

Reason:An error with connectivity module has been detected.

Effect:None on performance.

Circuit Description:The connectivity module is the data logging device. The connectivity module system collects data from the ECM via the vehicle J1939 network.The connectivity module is also the predictive cruise control system. The predictive cruise control system sends commands to the ECM via the vehicle J1939 network. Predictive cruise control dynamically adjust the vehicle speed profile while the vehicle is operating in cruise control. The vehicle speed profile is optimized for fuel economy based on the upcoming road grade.

Component Location:The connectivity module is either located on the engine or in the vehicle cabin.

Conditions for Running the Diagnostic:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes:The connectivity module reported an internal error of the connectivity module.

Action Taken When the Fault Code is Active:1. The ECM logs the fault code immediately when the diagnostic runs and fails.2. The connectivity module may not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 2 minute.2. The fault code status displayed by the recommended diagonstic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.

Shop Talk:Possible causes of this fault code include:A malfunctioning connectivity module.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8179 PID: SPN: 8179 FMI: 9/9 Automated Driving System TSC1-P7 – Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8157 PID: SPN: 521209 FMI: 11/31 Connectivity Module – Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8156 PID: SPN: 521209 FMI: 9/9 Connectivity Module – Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8155 PID: SPN: 521209 FMI: 12/12 Connectivity Module – Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8154 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7935 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change

Leer más →