Ir directamente al contenido

Telegram : @Diezel365

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4839 PID: SPN: 3667 FMI: 31 Engine Air Shutoff- Condition Exists

Circuit DescriptionThe engine control module (ECM) controls the engine intake air throttle actuator. The ECM can open and close the throttle based on the operating condtions in order to regulate air flow to the engine.

Component LocationThe engine intake air throttle actuator is mounted in the piping between the charge air cooler and intake manifold.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected active Engine Intake Air Throttle faults.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis is an information only fault that sets when there are one or more active Engine Intake Air Throttle faults when the Engine Intake Air Throttle has been configured as an Air Shutoff.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4769 PID: SPN: 1761 FMI: 10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4768 PID: SPN: 3521 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Property- Root Cause Not known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4751 PID: SPN: 3227 FMI: 21 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4749 PID: SPN: 3227 FMI: 20 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4748 PID: SPN: 3217 FMI: 21 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4747 PID: SPN: 3217 FMI: 20 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted High