Ir directamente al contenido

Telegram : @Diezel365

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4732 PID: SPN: 1761 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Out of Calibration

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank level sensor is used to monitor the aftertreatment diesel exhaust fluid level inside the aftertreatment diesel exhaust fluid tank.

Component LocationThe aftertreatment diesel exhaust fluid tank level sensor is located in the aftertreatment diesel exhaust fluid tank. Location of the tank and level sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the SAE J1939 datalink message received from the aftertreatment diesel exhaust fluid tank level sensor was NOT valid.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel exhaust fluid tank level sensor

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4731 PID: SPN: 3031 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4728 PID: SPN: 1209 FMI: 18 Exhaust Gas Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4727 PID: SPN: 157 FMI: 15 Injector Metering rail 1 Pressure- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4726 PID: SPN: 1239 FMI: 16 Engine Fuel Leakage- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4691 PID: SPN: 5585 FMI: 18 Engine Injector Metering Rail 1 Cranking Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4677 PID: SPN: 1761 FMI: 9 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Abnormal Update Rate