Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4449 PID: SPN: 6773 FMI: 16 Aftertreatment 1 Particulate Sensor Regeneration Status- Data Valid But Above Normal Operating range- Moderately Severe Level

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe residual current flow through the sensor after a sensor regeneration was higher than a threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensorInternal engine damage.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4294 PID: SPN: 5097 FMI: 4 Engine Brake Active lamp- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4293 PID: SPN: 5097 FMI: 3 Engine Brake Active lamp- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4289 PID: SPN: 91 FMI: 8 Accelerator Pedal or Lever Position Sensor 1 Circuit Frequency- Abnormal Frequency or Pulse Width or Period
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4281 PID: SPN: 5848 FMI: 2 Aftertreatment 1 SCR Intermediate NH3- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4277 PID: SPN: 3364 FMI: 10 Aftertreatment Diesel Exhaust Fluid Quality- Abnormal Update Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4261 PID: SPN: 5743 FMI: 11 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Root Cause Not Known