Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4171 PID: SPN: 5745 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit 1 Heater- Data valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe aftertreatment diesel exhaust fluid dosing unit heater is used to defrost and/or prevent freezing of the diesel exhaust fluid dosing unit.

Component LocationThe aftertreatment diesel exhaust fluid dosing unit location is original equipment manufacturer (OEM) dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment diesel exhaust fluid dosing unit heater is commanded ON.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid dosing unit failed to reach a target temperature after heating for a calibratable amount of time.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and then use INSITE™ electronic service tool to perform the Diesel Exhaust Fluid Doser System Heater Test found under ECM Diagnostic Tests.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel exhaust fluid dosing unit heater

Possible Cause:1) Aftertreatment DEF dosing unit failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4169 PID: SPN: 5745 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit 1 Heater Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4168 PID: SPN: 5745 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit 1 Heater Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4166 PID: SPN: 5743 FMI: 16 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4165 PID: SPN: 5743 FMI: 4 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4164 PID: SPN: 5743 FMI: 3 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4163 PID: SPN: 5742 FMI: 16 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Data Valid But Above Normal Operating Range- Moderately Severe Level