Ir directamente al contenido

Telegram : @Diezel365

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4165 PID: SPN: 5743 FMI: 4 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment SCR temperature sensor module reported low battery supply voltage.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Incorrect Battery System Voltage setting in INSITEIncorrect sensor for the application (12 VDC versus 24 VDC)Low battery voltage supply

Possible Cause:1) Aftertreatment SCR temperature sensor module failure2) Loose connections3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4164 PID: SPN: 5743 FMI: 3 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4163 PID: SPN: 5742 FMI: 16 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4162 PID: SPN: 5742 FMI: 4 Aftertreatment Diesel Particulate Filter Temperture Sensor Module- Voltage Below Normal or Shorted to low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4161 PID: SPN: 5742 FMI: 3 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4159 PID: SPN: 5743 FMI: 12 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4158 PID: SPN: 5742 FMI: 12 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Bad Intelligent Deivce Or Component