Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3737 PID: SID 115 SPN: 1675 FMI: 31 Engine Starter Mode Overcrank Protection- Condition Exists

Circuit DescriptionThe overcrank protection feature (or starter lockout) is designed to prevent damage to the starter motor during hard start conditions. Excessive cranking of the engine can cause the starter motor to overheat, resulting in permanent damage. When excessive engine cranking is detected, the overcrank protection feature locks out the starter until the starter motor has adequately cooled, and is safe to operate again.

Component LocationThe overcrank protection feature is controlled by the ECM, and can not be modified.

Conditions for Running the DiagnosticsThis diagnostic runs when the engine is being started.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the starter motor was engaged for a long enough period of time that continued cranking can cause starter damage. This cumulative time includes continuous cranking and/or a series of shorter cranking attempts within a certain time window.

Action Taken When the Fault Code is ActiveThe starter is locked out and the engine can not be cranked over until the starter motor has adequately cooled.Conditions for Clearing the Fault CodeThe fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis is an information only fault code, and does not indicate an issue with the starter.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3734 PID: PID 102 SPN: 862 FMI: 4 Crankcase Breather Filter Heater Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3733 PID: SPN: 862 FMI: 3 Crankcase Breather Filter Heater Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3727 PID: SID 254 SPN: 5571 FMI: 7 High-Pressure Common Rail Fuel Pressure Relief Valve- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3725 PID: PID 102 SPN: 3216 FMI: 10 Aftertreatment Intake Nox Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3724 PID: PID 168 SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3716 PID: SPN: 188 FMI: 18 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level