Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3716 PID: SPN: 188 FMI: 18 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe Engine Control Module (ECM) continuously monitors the engine speed at idle and adjusts fueling to maintain governed idle speed.

Component LocationThe engine speed is monitored by the crankshaft and/or camshaft position sensors.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is operating at idle and PTO is not active.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine speed was 50 rpm below governed idle speed for 30 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Fuel system malfunctionCrankshaft position sensor malfunctionCamshaft position sensor malfunctionIncreased engine accessory load

Possible Cause:1) Crankshaft engine speed sensor, and camshaft engine position Sensor2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3715 PID: SPN: 188 FMI: 16 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3714 PID: SID 115 SPN: 1569 FMI: 31 Engine Protection Torque Derate- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3712 PID: PID 105 SPN: 5246 FMI: 0 Aftertreatment SCR Operator Inducement- Data valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3697 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3682 PID: PID 190 SPN: 3218 FMI: 2 Aftertreatment Intake Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3681 PID: PID 411 SPN: 3228 FMI: 2 Aftertreatment Outlet Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect